Objectives We evaluated the prognostic value of myocardial flow reserve (MFR) using rubidium-82 (82 Rb) positron emission tomography (PET) in patients assessed for ischemia. Background The clinical ...value of MFR quantification using82 Rb PET beyond relative myocardial perfusion imaging remains uncertain. Methods We prospectively enrolled 704 consecutive patients; 677 (96%) completed follow-up (median 387 days interquartile range: 375 to 416 days). Patients were divided into 4 groups: I, normal summed stress score (SSS) (<4) and normal myocardial flow reserve (MFR) (>2); II, normal SSS and MFR <2; III, SSS ≥4 and MFR ≥2; IV, SSS ≥4 and MFR <2. Results For patients with a normal SSS and those with an abnormal SSS, there were significant differences in outcomes for hard events (cardiac death and myocardial infarction) between patients with MFR ≥2 and those with MFR <2 (I: 1.3% vs. II: 2% p = 0.029; III: 1.1% vs. IV: 11.4% p = 0.05) and for major adverse cardiac events (MACE) (p = 0.003 and p < 0.001, respectively). In the adjusted Cox model, MFR was an independent predictor of hard events (hazard ratio: 3.3; 95% confidence interval: 1.1 to 9.5; p = 0.029) and MACE (hazard ratio: 2.4, 95% confidence interval: 1.4 to 4.4, p = 0.003). The incremental prognostic value of the MFR over the SSS was demonstrated by comparing the adjusted SSS model with and without the MFR for hard events (p = 0.0197) and MACE (p = 0.002). Conclusions MFR quantified using82 Rb PET predicts hard cardiac events and MACE independent of the SSS and other parameters. Routine assessment of82 Rb PET–quantified MFR could improve risk stratification for patients being investigated for ischemia.
Purpose of Review
This review aims to discuss the use of fluorodeoxyglucose (FDG) positron emission tomography (PET/CT) for diagnosis and management of patients with large-vessel vasculitis (LVV).
...Recent Findings
Incidence of LVV is likely underestimated, in part due to its non-specific symptoms. Nevertheless, early diagnosis of LVV is essential to initiate timely therapy in order to prevent vascular complications, such as stenoses and aneurysms. FDG PET/CT imaging has the ability to detect LVV during the acute phase, prior to edema and other vascular structural changes, with its high sensitivity for inflammatory activity. FDG PET/CT was shown to be a powerful prognostic marker by allowing identification of patients at risk of vascular complications. Additionally, preliminary data support the use of FDG PET/CT to follow therapy efficacy.
Summary
FDG PET/CT allows early detection of inflammation, before morphological and irreversible vascular changes can be observed, allowing prompt diagnosis and treatment of LVV.
Combined analysis of SPECT myocardial perfusion imaging (MPI) performed with a solid-state camera on patients in 2 positions (semiupright, supine) is routinely used to mitigate attenuation artifacts. ...We evaluated the prediction of obstructive disease from combined analysis of semiupright and supine stress MPI by deep learning (DL) as compared with standard combined total perfusion deficit (TPD).
1,160 patients without known coronary artery disease (64% male) were studied. Patients underwent stress
Tc-sestamibi MPI with new-generation solid-state SPECT scanners in 4 different centers. All patients had on-site clinical reads and invasive coronary angiography correlations within 6 mo of MPI. Obstructive disease was defined as at least 70% narrowing of the 3 major coronary arteries and at least 50% for the left main coronary artery. Images were quantified at Cedars-Sinai. The left ventricular myocardium was segmented using standard clinical nuclear cardiology software. The contour placement was verified by an experienced technologist. Combined stress TPD was computed using sex- and camera-specific normal limits. DL was trained using polar distributions of normalized radiotracer counts, hypoperfusion defects, and hypoperfusion severities and was evaluated for prediction of obstructive disease in a novel leave-one-center-out cross-validation procedure equivalent to external validation. During the validation procedure, 4 DL models were trained using data from 3 centers and then evaluated on the 1 center left aside. Predictions for each center were merged to have an overall estimation of the multicenter performance.
718 (62%) patients and 1,272 of 3,480 (37%) arteries had obstructive disease. The area under the receiver operating characteristics curve for prediction of disease on a per-patient and per-vessel basis by DL was higher than for combined TPD (per-patient, 0.81 vs. 0.78; per-vessel, 0.77 vs. 0.73;
< 0.001). With the DL cutoff set to exhibit the same specificity as the standard cutoff for combined TPD, per-patient sensitivity improved from 61.8% (TPD) to 65.6% (DL) (
< 0.05), and per-vessel sensitivity improved from 54.6% (TPD) to 59.1% (DL) (
< 0.01). With the threshold matched to the specificity of a normal clinical read (56.3%), DL had a sensitivity of 84.8%, versus 82.6% for an on-site clinical read (
= 0.3).
DL improves automatic interpretation of MPI as compared with current quantitative methods.
Absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) provide incremental diagnostic and prognostic information over relative perfusion alone. Recent development of dedicated cardiac ...SPECT cameras with better sensitivity and temporal resolution make dynamic SPECT imaging more practical. In this study, we evaluate the measurement of MBF using a multipinhole dedicated cardiac SPECT camera in a pig model of rest and transient occlusion at stress using 3 common tracers: (201)Tl, (99m)Tc-tetrofosmin, and (99m)Tc-sestamibi.
Animals (n = 19) were injected at rest/stress with (99m)Tc radiotracers (370/1,100 MBq) or (201)Tl (37/110 MBq) with a 1-h delay between rest and dipyridamole stress. With each tracer, microspheres were injected simultaneously as the gold standard measurement for MBF. Dynamic images were obtained for 11 min starting with each injection. Residual resting activity was subtracted from stress data and images reconstructed with CT-based attenuation correction and energy window-based scatter correction. Dynamic images were processed with kinetic analysis software using a 1-tissue-compartment model to obtain the uptake rate constant K(1) as a function of microsphere MBF.
Measured extraction fractions agree with those obtained previously using ex vivo techniques. Converting K(1) back to MBF using the measured extraction fractions produced accurate values and good correlations with microsphere MBF: r = 0.75-0.90 (P < 0.01 for all). The correlation in the MFR was between r = 0.57 and 0.94 (P < 0.01).
Noninvasive measurement of absolute MBF with stationary dedicated cardiac SPECT is feasible using common perfusion tracers.
Myocardial blood flow (MBF) and myocardial flow reserve (MFR) measured with PET have clinical value. SPECT cameras with solid-state detectors can obtain dynamic images for measurement of MBF and MFR. ...In this study, SPECT measurements of MBF made using
Tc-tetrofosmin were compared with PET in the same patients.
Thirty-one patients underwent PET MBF rest-stress studies performed with
Rb or
N-ammonia within 1 mo of their SPECT study. Dynamic rest-stress measurements were made using a SPECT camera. Kinetic parameters were calculated using a 1-tissue-compartment model and converted to MBF and MFR. Processing with and without corrections for attenuation (+AC and -AC), patient body motion (+MC and -MC), and binding of the tracer to red blood cells (+BB and -BB) was evaluated.
Both +BB and +MC improved the accuracy and precision of global SPECT MBF compared with PET MBF, resulting in an average difference of 0.06 ± 0.37 mL/min/g. Global MBF and detection of abnormal MFR were not significantly improved with +AC. Global SPECT MFR with +MC and +BB had an area under the receiver-operating curve of 0.90 (+AC) to 0.95 (-AC) for detecting abnormal PET MFR less than 2.0. Regional analysis produced similar results with an area under the receiver-operating curve of 0.84 (+AC) to 0.87 (-AC).
Solid-state SPECT provides global MBF and MFR measurements that differ from PET by 2% ± 32% (MBF) and 2% ± 28% (MFR).
The study evaluated the automatic prediction of obstructive disease from myocardial perfusion imaging (MPI) by deep learning as compared with total perfusion deficit (TPD).
Deep convolutional neural ...networks trained with a large multicenter population may provide improved prediction of per-patient and per-vessel coronary artery disease from single-photon emission computed tomography MPI.
A total of 1,638 patients (67% men) without known coronary artery disease, undergoing stress
Tc-sestamibi or tetrofosmin MPI with new generation solid-state scanners in 9 different sites, with invasive coronary angiography performed within 6 months of MPI, were studied. Obstructive disease was defined as ≥70% narrowing of coronary arteries (≥50% for left main artery). Left ventricular myocardium was segmented using clinical nuclear cardiology software and verified by an expert reader. Stress TPD was computed using sex- and camera-specific normal limits. Deep learning was trained using raw and quantitative polar maps and evaluated for prediction of obstructive stenosis in a stratified 10-fold cross-validation procedure.
A total of 1,018 (62%) patients and 1,797 of 4,914 (37%) arteries had obstructive disease. Area under the receiver-operating characteristic curve for disease prediction by deep learning was higher than for TPD (per patient: 0.80 vs. 0.78; per vessel: 0.76 vs. 0.73: p < 0.01). With deep learning threshold set to the same specificity as TPD, per-patient sensitivity improved from 79.8% (TPD) to 82.3% (deep learning) (p < 0.05), and per-vessel sensitivity improved from 64.4% (TPD) to 69.8% (deep learning) (p < 0.01).
Deep learning has the potential to improve automatic interpretation of MPI as compared with current clinical methods.