This study evaluated the biocompatibility and biological performance of novel additive-manufactured bioabsorbable iron-based porous suture anchors (iron_SAs). Two types of bioabsorbable iron_SAs, ...with double- and triple-helical structures (iron_SA_2_helix and iron_SA_3_helix, respectively), were compared with the synthetic polymer-based bioabsorbable suture anchor (polymer_SAs). An in vitro mechanical test, MTT assay, and scanning electron microscope (SEM) analysis were performed. An in vivo animal study was also performed. The three types of suture anchors were randomly implanted in the outer cortex of the lateral femoral condyle. The ultimate in vitro pullout strength of the iron_SA_3_helix group was significantly higher than the iron_SA_2_helix and polymer_SA groups. The MTT assay findings demonstrated no significant cytotoxicity, and the SEM analysis showed cells attachment on implant surface. The ultimate failure load of the iron_SA_3_helix group was significantly higher than that of the polymer_SA group. The micro-CT analysis indicated the iron_SA_3_helix group showed a higher bone volume fraction (BV/TV) after surgery. Moreover, both iron SAs underwent degradation with time. Iron_SAs with triple-helical threads and a porous structure demonstrated better mechanical strength and high biocompatibility after short-term implantation. The combined advantages of the mechanical superiority of the iron metal and the possibility of absorption after implantation make the iron_SA a suitable candidate for further development.
This study evaluated the mid-term (12-month) biomechanical, biocompatibility, and biological performance of additive-manufactured bioabsorbable iron-based interference screws (ISs). Two bioabsorbable ...iron IS types-manufactured using pure iron powder (iron_IS) and using pure iron powder with 0.2 wt% tricalcium phosphate (TCP_IS)-were compared with conventional metallic IS (control) using in vitro biocompatibility and degradation analyses and an in vivo animal study. The in vitro ultimate failure strength was significantly higher for iron_IS and TCP_IS than for control ISs at 3 months post-operatively; however, the difference between groups were nonsignificant thereafter. Moreover, at 3 months after implantation, iron_IS and TCP_IS increased bone volume fraction, bone surface area fraction, and percent intersection surface; the changes thereafter were nonsignificant. Iron_IS and TCP_IS demonstrated degradation over time with increased implant surface, decreased implant volume, and structure thickness; nevertheless, the analyses of visceral organs and biochemistry demonstrated normal results, except for time-dependent iron deposition in the spleen. Therefore, compared with conventional ISs, bioabsorbable iron-based ISs exhibit higher initial mechanical strength. Although iron-based ISs demonstrate high biocompatibility 12 months after implantation, their corrosive iron products may accumulate in the spleen. Because they demonstrate mechanical superiority along with considerable absorption capability after implantation, iron-based ISs may have potential applications in implantable medical-device development in the future.
Peripheral nerve injuries, causing sensory and motor impairment, affect a great number of patients annually. It is therefore important to incorporate different strategies to promote nerve healing. ...Among the treatment options, however, the efficacy of nerve conduits is often compromised by their lack of living cells, insufficient growth factors, and absence of the extracellular matrix (ECM)-like structure. To improve the functional recovery, we aimed to develop a natural biodegradable multichanneled scaffold characterized with aligned electrospun nanofibers and neurotrophic gradient (MC/AN/NG) to guide axon outgrowth. The gelatin-based conduits mimicked the fascicular architecture of natural nerve ECM. The multichanneled (MC) scaffolds, cross-linked with microbial transglutaminase, possessed sustainable mechanical stability. Meanwhile, the release profile of dual neurotrophic factors, nerve growth factor (NGF) and brain-derived neurotrophic factor (BDNF), exhibited a temporal-controlled manner. In vitro, the differentiated neural stem cells effectively extended their neurites along the aligned nanofibers. Besides, in the treated group, the cell density increased in high NGF concentration regions of the gradient membrane, and the BDNF significantly promoted myelination. In a rabbit sciatic nerve transection in vivo model, the MC/AN/NG scaffold showed superior nerve recovery and less muscle atrophy comparable to autograft. By integrating multiple strategies to promote peripheral nerve regeneration, the MC/AN/NG scaffolds as nerve guidance conduits showed promising results and efficacious treatment alternatives for autologous nerve grafts.
Purpose
To analyze the tissue morphology around implant‐supported prostheses by digital technology and to evaluate the effect of prosthetic contours on the changes in tissues following the free ...gingiva graft procedure.
Material and methods
A total of 53 implants in 32 patients receiving free gingiva grafts were selected. These had previously presented insufficient keratinized mucosa width (KMW). At the follow‐up visits (mean: 16.66 ± 9.97 months), the implant position and tissue condition were documented with an oral scanner. Vertical soft tissue thickness (VT), measured from the implant‐abutment connection to the marginal tissues, and horizontal soft tissue thickness (HT), at the level of the platform, were calculated. The VT, HT, and emergence angle (EA) of prostheses were assessed by 3Shape analyzing software. The final KMW was measured by clinical assessment. Marginal bone loss (MBL) was calculated in the follow‐up bitewing radiographs.
Results
The mean VT in the study was 2.65 ± 0.75 mm at the mid‐buccal sites, 3.74 ± 1.22 mm at the mesial, 3.16 ± 1.08 mm at the distal, and 2.53 ± 0.92 at the mid‐lingual aspects. The mid‐buccal HT was 1.45 ± 0.53 mm while the mid‐lingual was 1.05 ± 0.43 mm (p = 0.008). Interestingly, prostheses with mid‐buccal EA>$\; > \;$30° exhibited slightly lower VT, but higher HT, than the ones with EA≤$\; \le \;$30°. Prostheses with proximal EA > 30° displayed slightly more MBL, compared to prostheses with EA≤$\; \le \;$30°. The mean KMW was 4.08 ± 1.10 mm.
Conclusions
Free gingival grafting is a predictable treatment approach to augmenting soft tissue 3‐dimensionally. Prostheses with EA≤$\; \le \;$30° were preferable for preserving the maximal VT and maintaining crestal bone stability.
Implant-related infection may be catastrophic and result in poor functional outcome, chronic osteomyelitis, implant failure or even sepsis and death. Based on a transglutaminase (TGase) ...cross-linked/antibiotics-encapsulated gelatin-alginate hydrogel, the main aim of this study is to establish an effective antibiotic slow-release system. The second aim is to evaluate the efficacy of a hydrogel-encapsulated antibiotic-containing titanium pin in preventing implant-related infections in a rat model. The prepared gelatin/alginate/gentamicin or vancomycin hydrogel was covalently cross-linked with transglutaminase (TGase). Its drug release profile and cytotoxicity were determined and the Wistar rat animal model was performed to validate its efficacy by radiographic examination, Micro-CT (computed tomography) evaluation and histo-morphological analysis at 12 weeks after surgery. When gelatin and alginate were thoroughly mixed with TGase, both 0.5% and 1.0% TGase can effectively cross link the hydrogel; the release of antibiotic is slowed down with higher degree of TGase concentration (from 20 min to more than 120 h). In the animal study, antibiotic-impregnated hydrogel is effective in alleviating the implant-related infections. Relative to that of a positive control group, the experimental group (vancomycin treatment group) showed significant higher bone volume, more intact bony structure with only mild inflammatory cell infiltration. This newly designed hydrogel can effectively deliver antibiotics to reduce bacterial colonization and biofilm formation on the implant surface. The remaining challenges will be to confer different potent antibacterial medications with good biocompatibility and fulfill the safety, practical and economic criteria for future clinical translation.
Degenerative disc disease is one of the most common ailments severely affecting the quality of life in elderly population. Cervical intervertebral body fusion devices are utilized to provide ...stability after surgical intervention for cervical pathology. In this study, we design a biomimetic porous spinal cage, and perform mechanical simulations to study its performances following American Society for Testing and Materials International (ASTM) standards before manufacturing to improve design process and decrease cost and consumption of material.
The biomimetic porous Ti-6Al-4 V interbody fusion devices were manufactured by selective laser melting (laser powder bed fusion: LPBF in ISO/ASTM 52900 standard) and subsequently post-processed by using hot isostatic pressing (HIP). Chemical composition, microstructure and the surface morphology were studied. Finite element analysis and in vitro biomechanical test were performed.
The post heat treatment can optimize its mechanical properties, as the stiffness of the cage decreases to reduce the stress shielding effect between two instrumented bodies. After the HIP treatment, the ductility and the fatigue performance are substantially improved. The use of HIP post-processing can be a necessity to improve the physical properties of customized additive manufacturing processed implants.
In conclusion, we have successfully designed a biomimetic porous intervertebral device. HIP post-treatment can improve the bulk material properties, optimize the device with reduced stiffness, decreased stress shielding effect, while still provide appropriate space for bone growth.
The biomechanical performance of 3-D printed biomimetic porous intervertebral device can be optimized. The ductility and the fatigue performance were substantially improved, the simultaneously decreased stiffness reduces the stress shielding effect between two instrumented bodies; while the biomimetic porous structures provide appropriate space for bone growth, which is important in the patients with osteoporosis.
: Metal pins used to apply skeletal traction or external fixation devices protruding through skin are susceptible to the increased incidence of pin site infection. In this work, we tried to ...establish the photokilling effects of titanium dioxide (TiO2) nanoparticles on an orthopedic implant with an in vitro study. In these photocatalytic experiments, aqueous TiO2 was added to the tested microorganism. The time effect of TiO2 photoactivation was evaluated, and the loss of viability of five different bacteria suspensions (Escherichia coli, Pseudomonas aeruginosa, Staphylococus aureus, Enterococcus hirae, and Bacteroides fragilis) was examined by the viable count procedure. The bactericidal effect of TiO2 nanoparticle‐coated metal plates was also tested. The ultraviolet (UV) dosage used in this experiment did not affect the viability of bacteria, and all bacteria survived well in the absence of TiO2 nanoparticles. The survival curve of microorganisms in the presence of TiO2 nanoparticles showed that nearly complete killing was achieved after 50 min of UV illumination. The formation of bacterial colonies above the TiO2 nanoparticle‐coated metal plates also decreased significantly. In this study, we clearly demonstrated the bactericidal effects of titanium dioxide nanoparticles. In the presence of UV light, the titanium dioxide nanoparticles can be applicable to medical facilities where the potential for infection should be controlled.
As the growth of the aging population continues to accelerate globally, increased prevalence of neurodegenerative diseases, including Alzheimer’s disease (AD), Parkinson’s disease (PD), and stroke, ...has generated substantial public concern. Unfortunately, despite of discoveries of common factors underlying these diseases, few drugs are available to effectively treat these diseases. Peroxisome proliferator-activated receptor gamma (PPAR-γ) is a ligand-activated transcriptional factor that belongs to the nuclear hormone receptor superfamily. PPAR-γ has been shown to influence the expression or activity of a large number of genes in a variety of signaling networks, including regulation of insulin sensitivity, glucose homeostasis, fatty acid oxidation, immune responses, redox balance, cardiovascular integrity, and cell fates. Recent epidemiological, preclinical animal, and clinical studies also show that PPAR-γ agonists can lower the incidence of a number of neurological disorders, despite of multiple etiological factors involved in the development of these disorders. In this manuscript, we review current knowledge on mechanisms underlying the beneficial effect of PPAR-γ in different neurodegenerative diseases, in particular, AD, PD, and stroke, and attempt to analyze common and overlapping features among these diseases. Our investigation unveiled information suggesting the ability for PPAR-γ to inhibit NF-κB-mediated inflammatory signaling at multiple sites, and conclude that PPAR-γ agonists represent a novel class of drugs for treating neuroinflammatory diseases.
Although a range of pharmacological interventions is available, it remains uncertain which treatment for osteoporosis is more effective. This network meta-analysis study aimed to compare different ...drug efficacy and safety in randomized controlled trials (RCTs) for the treatment of postmenopausal osteoporosis. PubMed, EMBASE, MEDLINE, Clinicaltrial.gov, Cochrane library, Google scholar were searched up to 31 October 2020. Randomized placebo-controlled trials that reported measures of bone mineral density (BMD) percentage change and/or numbers of adverse events of postmenopausal osteoporosis patients were included. Network meta-analysis was conducted using frequentist approach. Ninety-four RCTs comprising 15,776 postmenopausal osteoporosis females were included in the network meta-analysis. Compared with placebo, most interventions showed increase in BMD change. According to surfaces under the cumulative ranking curves (SUCRAs), strontium ranelate, fluoride, and hormone replacement therapy were most effective in increasing total hip, lumbar spine, and distal radius BMD, respectively. Parathyroid hormone (PTH) was most effective in preventing new hip fracture. When taking into account all anatomic sites, bisphosphonate (BP), monoclonal antibody (mAb), and fluoride have a balanced efficacy in increasing BMD at all sites. Considering both the effectiveness of increasing BMD and preventing hip fracture, mAb, BP, and PTH are more favorable among all interventions. The treatment effects of different medications on BMD percentage change are anatomic site-dependent. After weighing anti-osteoporosis treatment efficacy against risk of complications, BP and mAb are the more favorable interventions to increase BMD at all sites and reduce the risks of hip fracture and death.