Near-infrared diffuse optical tomography (DOT) has demonstrated a great potential as an adjunct modality for differentiation of malignant and benign breast lesions and for monitoring treatment ...response in patients with locally advanced breast cancers. The path toward commercialization of DOT techniques depends upon the improvement of robustness and user-friendliness of this technique in hardware and software. In this study, we introduce our recently developed ultrasound-guided DOT system, which has been improved in system compactness, robustness, and user-friendliness by custom-designed electronics, automated data preprocessing, and implementation of a new two-step reconstruction algorithm. The system performance has been tested with several sets of solid and blood phantoms and the results show accuracy in reconstructed absorption coefficients as well as blood oxygen saturation. A clinical example of a breast cancer patient, who was undergoing neoadjuvant chemotherapy, is given to demonstrate the system performance.
Lead toxicity is a barrier to the widespread commercial manufacture of lead halide perovskites and their use in solar photovoltaic (PV) devices. Eco-friendly lead-free perovskite solar cells (PSCs) ...have been developed using certain unique non- or low-toxic perovskite materials. In this context, Sn-based perovskites have been identified as promising substitutes for Pb-based perovskites due to their similar characteristics. However, Sn-based perovskites suffer from chemical instability, which affects their performance in PSCs. This study employs theoretical simulations to identify ways to improve the efficiency of Sn-based PSCs. The simulations were conducted using the SCAPS-1D software, and a lead-free, non-toxic, and inorganic perovskite absorber layer (PAL), i.e. CsSnI3 was used in the PSC design. The properties of the hole transport layer (HTL) and electron transport layer (ETL) were tuned to optimize the performance of the device. Apart from this, seven different combinations of HTLs were studied, and the best-performing combination was found to be ITO/PCBM/CsSnI3/CFTS/Se, which achieved a power conversion efficiency (PCE) of 24.73%, an open-circuit voltage (VOC) of 0.872 V, a short-circuit current density (JSC) of 33.99 mA cm−2 and a fill factor (FF) of 83.46%. The second highest PCE of 18.41% was achieved by the ITO/PCBM/CsSnI3/CuSCN/Se structure. In addition to optimizing the structure of the PSC, this study also analyzes the current density–voltage (J–V) along with quantum efficiency (QE), as well as the impact of series resistance, shunt resistance, and working temperature, on PV performance. The results demonstrate the potential of the optimized structure identified in this study to enhance the standard PCE of PSCs. Overall, this study provides important insights into the development of lead-free absorber materials and highlights the potential of using CsSnI3 as the PAL in PSCs. The optimized structure identified in this study can be used as a base for further research to improve the efficiency of Sn-based PSCs.
This paper presents a novel single-phase to single-phase multiconverter topology that can be applied in multiple areas. The proposed multiconverter is designed with only two soft power semiconductor ...switches (e.g. MOSFET or IGBT), four power diodes and a center-tapped transformer which makes it more compact in size, decrease the gate driving complexity, reduce the total equipment costs and enhance the energy conversion efficiency with minimized losses. Furthermore, the utilization of the transformer in the proposed converter mitigates the multiple AC source requirement problems and provides galvanic isolation which increases the reliability of the converter. Moreover, the presented multiconverter is applicable in various areas including electric traction as a speed controller, induction heating, AC and DC variable power supplies, etc. which signify the competence of this converter in energy conversion appliances. However, a comparative analysis of the offered converter with the existing AC-AC converters is also introduced in this paper with respect to the number of components, equipment costs, gate driving complexity, and application areas. In order to evaluate the performance of the proposed multiconverter, the simulation-based results carried out in MATLAB/Simulink are presented and analyzed in this paper with proper descriptions. Finally, a scaled-down prototype is developed in the laboratory to validate the simulation results and the feasibility of the proposed multiconverter.
Ultrasound (US) guided diffuse optical tomography has demonstrated great potential for breast cancer diagnosis, treatment monitoring, and chemotherapy response prediction. Optical measurements of ...four different wavelengths are used to reconstruct unknown optical absorption maps, which are then used to calculate the hemoglobin concentration distribution of the US visible lesion. Reconstructed absorption maps are prone to image artifacts from outliers in measurement data from tissue heterogeneity, bad coupling between tissue and light guides, and motion by patient or operator. We propose an automated iterative perturbation correction algorithm to reduce image artifacts based on the structural similarity index (SSIM) of absorption maps of four optical wavelengths. The initial image is estimated from the truncated pseudoinverse solution. The SSIM was calculated for each wavelength to assess its similarity with other wavelengths. An absorption map is repeatedly reconstructed and projected back into measurement space to quantify projection error. Outlier measurements with highest projection errors are iteratively removed until all wavelength images are structurally similar with SSIM values greater than a threshold. Clinical data demonstrate statistically significant improvement in image artifact reduction.
Ultrasound (US)-guided diffuse optical tomography (DOT) is a promising low-cost imaging technique for diagnosis and assessment of breast cancer. US-guided DOT is best implemented in reflection ...geometry, which can be co-registered with US pulse-echo imaging and also minimizes the tissue depth for adequate light penetration. However, due to intense light scattering, the DOT reconstruction problem is ill-posed. In this communication, we describe a new non-linear Born iterative reconstruction method with US-guided depth-dependent
sparse regularization for improving DOT reconstruction by incorporating
lesion depth and shape information from the co-registered US image. Our method iteratively solves the inverse problem by updating the photon-density wave using the finite difference method, computing the weight matrix based on Born approximation, and reconstructing the absorption map using the fast iterative shrinkage-thresholding optimization algorithm (FISTA). We validate our method using both phantom and patient data and compare the results with those using the first order linear Born method. Phantom experiments demonstrate that the non-linear Born method provides more accurate target absorption reconstruction and better resolution than the linear Born method. Clinical studies on 20 patients show that non-linear Born reconstructs more realistic tumor shapes than linear Born, and improves the malignant-to-benign lesion contrast ratio from
to
, which is a
improvement. For lesions approximately more than
cm in diameter, the average malignant-to-benign lesion contrast ratio is increased from
to
, which is a
improvement.
We report a new series of lipid-based biocompatible ionic liquids (LBILs) consisting of the long-chain phosphonium compound 1,2-dimyristoyl-sn-glycero-3-ethyl-phosphatidylcholine as the cation and ...the long-chain fatty acids stearic acid, oleic acid, or linoleic acid as anions. These materials were found to be completely miscible with many polar and nonpolar organic solvents as well as dispersible in water. These LBILs also exhibited excellent biocompatibility with an artificial three-dimensional human epidermis model.
Weaving is one of the most popular fabric manufacturing techniques. The weaving process consists of 3 major stages: warping, sizing, and weaving. The weaving factory henceforth involves a lot of ...data. But unfortunately, there is no attempt to utilize machine learning or data science in weaving production. Although a variety of scopes are there to implement statistical analysis, data science, and machine learning. The dataset was prepared by using the daily production report for 9 months. The final dataset contains 121,148 data with 18 parameters. Whereas the raw data contains the same number of entries with 22 columns. The raw data needs substantial work to combine the daily production report, treat the missing values, rename columns, and feature engineering to derive EPI, PPI, warp, weft count values, etc. The complete dataset is stored at https://data.mendeley.com/datasets/nxb4shgs9h/1. It is further processed to get the rejection dataset which is stored at https://data.mendeley.com/datasets/6mwgj7tms3/2. The future implementation of the dataset is to predict the weaving waste, investigate the statistical relations among various parameters, production prediction, etc.
Ultrasound (US)-guided near-infrared diffuse optical tomography (DOT) has demonstrated great potential as an adjunct breast cancer diagnosis tool to US imaging alone, especially in reducing ...unnecessary benign biopsies. However, DOT data processing and image reconstruction speeds remain slow compared to the real-time speed of US. Real-time or near real-time diagnosis with DOT is an important step toward the clinical translation of US-guided DOT. Here, to address this important need, we present a two-stage diagnostic strategy that is both computationally efficient and accurate. In the first stage, benign lesions are identified in near real-time by use of a random forest classifier acting on the DOT measurements and the radiologists' US diagnostic scores. Any lesions that cannot be reliably classified by the random forest classifier will be passed on to the second stage which begins with image reconstruction. Functional information from the reconstructed hemoglobin concentrations is employed by a Support Vector Machine (SVM) classifier for diagnosis at the end of the second stage. This two-step classification approach which combines both perturbation data and functional features, results in improved classification, as denoted by the receiver operating characteristic (ROC) curve. Using this two-step approach, the area under the ROC curve (AUC) is 0.937 ± 0.009, with a sensitivity of 91.4% and specificity of 85.7%. In comparison, using functional features and US score yields an AUC of 0.892 ± 0.027, with a sensitivity of 90.2% and specificity of 74.5%. Most notably, the specificity is increased by more than 10% due to the implementation of the random forest classifier.
Bangladesh is one of the world's most vulnerable countries for climate change. This observational study examined the association of temperature, humidity and rainfall with six common ...climate-sensitive infectious diseases in adults (malaria, diarrheal disease, enteric fever, encephalitis, pneumonia and bacterial meningitis) in northeastern Bangladesh. Subjects admitted to the adult medicine ward of a tertiary referral hospital in Sylhet, Bangladesh from 2008 to 2012 with a diagnosis of one of the six chosen climate-sensitive infectious diseases were enrolled in the study. Climate-related data were collected from the Bangladesh Meteorological Institute. Disease incidence was then analyzed against mean temperature, humidity and average rainfall for the Sylhet region. Statistical significance was determined using Mann-Whitney test, Chi-square test and ANOVA testing. 5033 patients were enrolled (58% male, 42% female, ratio 1.3:1). All six diseases showed highly significant (p = 0.01) rises in incidence between the study years 2008 (540 cases) and 2012 (1330 cases), compared with no significant rise in overall all-cause hospital admissions in the same period (p = 0.19). The highest number of malaria (135), diarrhea (266) and pneumonia (371) cases occurred during the rainy season. On the other hand, the maximum number of enteric fever (408), encephalitis (183) and meningitis (151) cases occurred during autumn, which follows the rainy season. A positive (P = 0.01) correlation was observed between increased temperature and the incidence of malaria, enteric fever and diarrhea, and a negative correlation with encephalitis, meningitis and pneumonia. Higher humidity correlated (P = 0.01) with a higher number of cases of malaria and diarrhea, but inversely correlated with meningitis and encephalitis. Higher incidences of encephalitis and meningitis occurred while there was low rainfall. Incidences of diarrhea, malaria and enteric fever, increased with rainfall, and then gradually decreased. The findings support a relationship between weather patterns and disease incidence, and provide essential baseline data for future large prospective studies.
Due to the correlated nature of diffused light, the problem of reconstructing optical properties using diffuse optical tomography (DOT) is ill-posed. US-, MRI- or x-ray-guided DOT approaches can ...reduce the total number of parameters to be estimated and improve optical reconstruction accuracy. However, when the target volume is large, the number of parameters to estimate can exceed the number of measurements, resulting in an underdetermined imaging model. In such cases, accurate image reconstruction is difficult and regularization methods should be employed to obtain a useful solution. In this manuscript, a simple two-step reconstruction method that can produce useful image estimates in DOT is proposed and investigated. In the first step, a truncated Moore-Penrose Pseudoinverse solution is computed to obtain a preliminary estimate of the image that can be reliably determined from the measured data; subsequently, this preliminary estimate is incorporated into the design of a penalized least squares estimator that is employed to compute the final image estimate. By use of phantom data, the proposed method was demonstrated to yield more accurate images than those produced by conventional reconstruction methods. The method was also evaluated with clinical data that included 10 benign and 10 malignant cases. The capability of reconstructing high contrast malignant lesions was demonstrated to be improved by use of the proposed method.