Semen analysis is difficult to standardize, quality control and quality assurance are necessary to ensure that results are accurate and precise. This Belgian EQA survey over a 15‐year period, ...involving 121 laboratories, attempted to reduce interlaboratory variability and at the same time, encouraged participating laboratories to implement correct techniques as advised by the WHO. Over the total period, the median coefficient of variation (CV) for sperm count, irrespective of the method used was 19.2%, while using improved Neubauer chamber resulted in a significantly (p < 0.001) lower median CV (14.4%). The overall median CV for rapid progressive motility was high (37.1%), but progressive motility (15.1%) and total motility (13.8%) were acceptable. Sperm morphology revealed a large variability in 79.4% irrespective of the staining procedures or evaluation criteria used. Participation in the Belgian EQA is on voluntary basis. Both, participation and implementation of the correct techniques should be made mandatory for accreditation and benefit of patient treatment. The existing Belgian EQA program should now be harmonized with other existing EQA schemes in Europe.
Summary
Introduction
The Belgian national External Quality Assessment Scheme performed a survey to assess the effect of the direct oral anticoagulant apixaban on the coagulation assays prothrombin ...time (PT), activated partial thromboplastin time (aPTT), fibrinogen and antithrombin as performed with a large number of reagent/instrument combinations.
Methods
Four lyophilized plasma samples spiked with apixaban (0, 41, 94 and 225 ng/mL) were sent to the 195 Belgian and Luxembourg clinical laboratories performing coagulation testing.
Results
PT and aPTT were barely influenced at the concentrations tested. At 225 ng/mL apixaban, PT and aPTT clotting times were only 1.15 times longer than at 0 ng/mL. Among PT reagents, RecombiPlasTin 2G® showed a slightly higher sensitivity with 225 ng/mL apixaban prolonging the PT clotting time 1.3‐fold. Among aPTT reagents, there was no appreciable difference in sensitivity.
Fibrinogen results were unaffected by the presence of apixaban, but antithrombin activity was considerably overestimated when measured with a FXa‐based assay. At 225 ng/mL apixaban, the median percentage increase in antithrombin level was 31% when measured with the Liquid Antithrombin® reagent and 44% with the Innovance Antithrombin® reagent.
Conclusion
Our data provide clinical laboratories with useful information on the impact of apixaban on their routine coagulation assays.
The actual burden of respiratory infections due to Chlamydophila pneumoniae is difficult to assess due to the major differences in positivity rates between PCRand serology-based methods. The aim of ...the current study was to objectively analyse the yield of PCRs for the detection of C. pneumoniae in respiratory samples and to evaluate the additional value of performing laboratory diagnosis for C. pneumoniae in a setting of respiratory infection. The data based on routine analysis of respiratory samples with request for C. pneumoniae detection were collected from 4 large Belgian hospitals during 2 consecutive years. In total 3560 respiratory samples have been analysed and overall only 7 samples (0.2%) were found positive. Based on these observations, the critical evaluation of the actual role of C. pneumoniae in the etiology of lower respiratory infections and consequently of the extensive use of diagnostic tools for the detection of C. pneumoniae is needed.
We report here on a new case of L. buccalis bacteraemia. To our knowledge 16 other cases of L. buccalis bacteraemia have been reported in the literature, most of them in neutropenic patients. However ...L buccalis endocarditis does occasionally occur in non-neutropenic patients. The identification of L. buccalis is based on well known phenotypic features and confirmed by the detection of a large peak of lactic acid by gas chromatography for non volatile organic acids. L. buccalis is sensitive to a wide range of antibiotics including beta-lactam antibiotics, but it is resistant to aminoglycosides and macrolides.
●Sciensano and its department Quality of Laboratories routinely organizes external quality assessment as a part of the mandatory external quality assessment program for SARS-CoV-2 serology in ...Belgium.●Sample IS/17575 generated highly discordant results.●The importance of the choice of antigenic composition.●Antibody response against the N 184 protein appears to wane post-infection.●Difference in sensitivity of RBD 192 vs S1 vs S protein based immunoassays.
We report on sample IS/17575 since it generated highly divergent results in the Belgian SARS-CoV-2 serology external quality assessment scheme. Sample IS/17575 was serum originating from a 30 years old male patient. 124 diagnostic laboratories analysed this sample. A total of 168 results was returned (including 5 doubles). Overall, 38 were positive. All tests against S1 were positive except the Euroimmun IgG ELISA and the Ortho clinical Diagnostics VITROS IgG CLIA. All tests against S1/S2 (Liaison, Diasorin) resulted in a signal above cutoff. Assays against RBD, mostly generate a negative result. An exception are the Wantai SARS-CoV-2 ELISA's. All tests targeting N protein were negative. The survey shows, when >6 months post-infection, assays targeting at least S1, and preferably S1 combined with S2, are the most sensitive. This finding accentuates the necessity of external quality assessment schedules and importance of antigenic composition of serologic SARS-CoV-2 assays.