Objective The purpose of the present study was to evaluate the early clinical outcomes of aortic root surgery in the United States. Methods The Society of Thoracic Surgeons database was queried to ...identify all patients who had undergone aortic root replacement from 2004 to early 2010 (n = 13,743). The median age was 58 years (range, 18-96); 3961 were women (29%) and 12,059 were white (88%). The different procedures included placement of a mechanical valve conduit (n = 4718, 34%), stented pericardial (n = 879, 6.4%) or porcine (n = 478, 3.5%) bioprosthesis, stentless root (n = 4309, 31%), homograft (n = 498, 3.6%), and valve sparing root replacement (n = 1918, 14%). Results The median number of aortic root surgeries per site was 2, and only 5% of sites performed >16 aortic root surgeries annually. An increased trend to use biostented (porcine or pericardial) valves during the study period (7% in 2004 vs 14% in 2009). The operative (raw) mortality was greater among the patients with aortic stenosis (6.2%) who had undergone aortic root replacement, independent of age. Mortality was greater in patients who had undergone concomitant valve or coronary artery bypass grafting or valve surgery (21%). The lowest operative mortality was observed in patients who had undergone aortic valve sparing procedures (1.9%). Conclusions Most cardiac centers performed aortic root surgery in small volumes. The unadjusted operative mortality was greater for patients >80 years old and those with aortic stenosis, regardless of age. Valve sparing root surgery was associated with the lowest mortality. A trend was seen toward an increased use of stented tissue valves from 2004 to 2009.
The decadal state of the terrestrial carbon cycle Bloom, A. Anthony; Exbrayat, Jean-François; van der Velde, Ivar R. ...
Proceedings of the National Academy of Sciences - PNAS,
02/2016, Volume:
113, Issue:
5
Journal Article
Peer reviewed
Open access
The terrestrial carbon cycle is currently the least constrained component of the global carbon budget. Large uncertainties stem from a poor understanding of plant carbon allocation, stocks, residence ...times, and carbon use efficiency. Imposing observational constraints on the terrestrial carbon cycle and its processes is, therefore, necessary to better understand its current state and predict its future state. We combine a diagnostic ecosystem carbon model with satellite observations of leaf area and biomass (where and when available) and soil carbon data to retrieve the first global estimates, to our knowledge, of carbon cycle state and process variables at a 1° × 1° resolution; retrieved variables are independent from the plant functional type and steady-state paradigms. Our results reveal global emergent relationships in the spatial distribution of key carbon cycle states and processes. Live biomass and dead organic carbon residence times exhibit contrasting spatial features (r = 0.3). Allocation to structural carbon is highest in the wet tropics (85–88%) in contrast to higher latitudes (73–82%),where allocation shifts toward photosynthetic carbon. Carbon use efficiency is lowest (0.42–0.44) in the wet tropics. We find an emergent global correlation between retrievals of leaf mass per leaf area and leaf lifespan (r = 0.64–0.80) that matches independent trait studies. We show that conventional land cover types cannot adequately describe the spatial variability of key carbon states and processes (multiple correlation median = 0.41). This mismatch has strong implications for the prediction of terrestrial carbon dynamics, which are currently based on globally applied parameters linked to land cover or plant functional types.
Abstract Objectives This study sought to determine the impact of quantity and location of aortic valve calcification (AVC) on paravalvular regurgitation (PVR) and rates of post-dilation (PD) ...immediately after transcatheter aortic valve replacement (TAVR). Background The impact of AVC in different locations within the aortic valve complex is incompletely understood. Methods This study analyzed 150 patients with severe, symptomatic aortic stenosis who underwent TAVR. Total AVC volume scores were calculated from contrast-enhanced multidetector row computed tomography imaging. AVC was divided by leaflet sector and region (Leaflet, Annulus, left ventricular outflow tract LVOT), and a combination of LVOT and Annulus (AnnulusLVOT). Asymmetry was assessed. Receiver-operating characteristic analysis was performed with greater than or equal to mild PVR and PD as classification variables. Logistic regression was performed. Results Quantity of and asymmetry of AVC for all regions of the aortic valve complex predicted greater than or equal to mild PVR by receiver-operating characteristic analysis (area under the curve = 0.635 to 0.689), except Leaflet asymmetry. Receiver-operating characteristic analysis for PD was significant for quantity and asymmetry of AVC in all regions, with higher area under the curve values than for PVR (area under the curve = 0.648 to 0.741). On multivariable analysis, Leaflet and AnnulusLVOT calcification were independent predictors of both PVR and PD regardless of multidetector row computed tomography area cover index. Conclusions Quantity and asymmetry of AVC in all regions of the aortic valve complex predict greater than or equal to mild PVR and performance of PD, with the exception of Leaflet asymmetry. Quantity of AnnulusLVOT and Leaflet calcification independently predict PVR and PD when taking into account multidetector row computed tomography area cover index.
The introduction of transcatheter aortic valve replacement mandates attention to outcomes after surgical aortic valve replacement (SAVR) in low-risk, intermediate-risk, and very high-risk patients.
...The study population included 141,905 patients who underwent isolated primary SAVR from 2002 to 2010. Patients were risk-stratified by Society of Thoracic Surgeons (STS) predicted risk of mortality (PROM) <4% (group 1, n = 113,377), 4% to 8% (group 2, n = 19,769), and >8% (group 3, n = 8,759). The majority of patients were considered at low risk (80%), and only 6.2% were categorized as being at high risk. Outcomes were analyzed based on two time periods: 2002 to 2006 (n = 63,754) and 2007 to 2010 (n = 78,151).
The mean age was 65 years in group 1, 77 in group 2, and 77 in group 3 (p < 0.0001). The median STS PROM for the entire population was 1.84: 1.46% in group 1, 5.24% in group 2, and 11.2% in group 3 (p < 0.0001). Compared with PROM, in-hospital mean mortality was lower than expected in all patients (2.5% vs 2.95%) and when analyzed within risk groups was as follows: group 1 (1.4% vs 1.7%), group 2 (5.1% vs 5.5%), and group 3 (11.8% vs 13.7%) (p < 0.0001). In the most recent surgical era, operative mortality was significantly reduced in group 2 (5.4% vs 6.4%, p = 0.002) and group 3 (11.9% vs 14.4%, p = 0.0004) but not in group 1.
Nearly 80% of patients undergoing SAVR have outcomes that are superior to those by the predicted risk models. In the most recent era, early results have further improved in medium-risk and high-risk patients. This large real-world assessment serves as a benchmark for patients with aortic valve stenosis as therapeutic options are further evaluated.
In low surgical risk patients with symptomatic severe aortic stenosis, the PARTNER 3 (Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis) ...trial demonstrated superiority of transcatheter aortic valve replacement (TAVR) versus surgery for the primary endpoint of death, stroke, or re-hospitalization at 1 year.
This study determined both clinical and echocardiographic outcomes between 1 and 2 years in the PARTNER 3 trial.
This study randomly assigned 1,000 patients (1:1) to transfemoral TAVR with the SAPIEN 3 valve versus surgery (mean Society of Thoracic Surgeons score: 1.9%; mean age: 73 years) with clinical and echocardiography follow-up at 30 days and at 1 and 2 years. This study assessed 2-year rates of the primary endpoint and several secondary endpoints (clinical, echocardiography, and quality-of-life measures) in this as-treated analysis.
Primary endpoint follow-up at 2 years was available in 96.5% of patients. The 2-year primary endpoint was significantly reduced after TAVR versus surgery (11.5% vs. 17.4%; hazard ratio: 0.63; 95% confidence interval: 0.45 to 0.88; p = 0.007). Differences in death and stroke favoring TAVR at 1 year were not statistically significant at 2 years (death: TAVR 2.4% vs. surgery 3.2%; p = 0.47; stroke: TAVR 2.4% vs. surgery 3.6%; p = 0.28). Valve thrombosis at 2 years was increased after TAVR (2.6%; 13 events) compared with surgery (0.7%; 3 events; p = 0.02). Disease-specific health status continued to be better after TAVR versus surgery through 2 years. Echocardiographic findings, including hemodynamic valve deterioration and bioprosthetic valve failure, were similar for TAVR and surgery at 2 years.
At 2 years, the primary endpoint remained significantly lower with TAVR versus surgery, but initial differences in death and stroke favoring TAVR were diminished and patients who underwent TAVR had increased valve thrombosis. (Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis PARTNER 3; NCT02675114)
Display omitted
Functional capacity as assessed by 6-minute walk test distance (6MWTD) has been shown to predict outcomes in selected cohorts with cardiovascular disease. To evaluate the association between 6MWTD ...and outcomes after transcatheter aortic valve implantation (TAVI) among participants in the Placement of AoRTic TraNscathetER valve (PARTNER) trial, TAVI recipients (n = 484) were stratified into 3 groups according to baseline 6MWTD: unable to walk (n = 218), slow walkers (n = 133), in whom 6MWTD was below the median (128.5 meters), and fast walkers (n = 133) with 6MWTD >128.5 meters. After TAVI, among fast walkers, follow-up 6MWTD decreased by 44 ± 148 meters at 12 months (p <0.02 compared with baseline). In contrast, among slow walkers, 6MWTD improved after TAVI by 58 ± 126 meters (p <0.001 compared with baseline). Similarly, among those unable to walk, 6MWTD distance increased by 66 ± 109 meters (p <0.001 compared with baseline). There were no differences in 30-day outcomes among 6MWTD groups. At 2 years, the rate of death from any cause was 42.5% in those unable to walk, 31.2% in slow walkers, and 28.8% in fast walkers (p = 0.02), driven primarily by differences in noncardiac death. In conclusion, among high-risk older adults undergoing TAVI, baseline 6MWTD does not predict procedural outcomes but does predict long-term mortality. Nonetheless, patients with poor baseline functional status exhibit the greatest improvement in 6MWTD. Additional work is required to identify those with poor functional status who stand to benefit the most from TAVI.
Paravalvular leak (PVL) is a frequent complication of transcatheter aortic valve replacement (TAVR) and is seen at a much higher rate after TAVR than after conventional surgical aortic valve ...replacement. Recent reports indicating that PVL may be correlated with increased late mortality have raised concerns. However, the heterogeneity of methods for assessing and quantifying PVL, and lack of consistency in the timing of such assessments, is a hindrance to understanding its true prevalence, severity, and effect. This literature review is an effort to consolidate current knowledge in this area to better understand the prevalence, progression, and impact of post-TAVR PVL and to help direct future efforts regarding the assessment, prevention, and treatment of this troublesome complication.
Objectives This study sought to identify incidence, predictors, and impact of vascular complications (VC) after transfemoral (TF) transcatheter aortic valve replacement (TAVR). Background VC after ...TF-TAVR are frequent and may be associated with unfavorable prognosis. Methods From the randomized controlled PARTNER (Placement of AoRTic TraNscathetER Valve) trial, a total of 419 patients (177 from cohort B inoperable and 242 from cohort A operable high-risk) were randomly assigned to TF-TAVR and actually received the designated treatment. First-generation Edwards-Sapien valves and delivery systems were used, via a 22- or 24-F sheath. The 30-day rates of major and minor VC (modified Valve Academic Research Consortium definitions), predictors, and effect on 1-year mortality were assessed. Results Sixty-four patients (15.3%) had major VC and 50 patients (11.9%) had minor VC within 30 days of the procedure. Among patients with major VC, vascular dissection (62.8%), perforation (31.3%), and access-site hematoma (22.9%) were the most frequent modes of presentation. Major VC, but not minor VC, were associated with significantly higher 30-day rates of major bleeding, transfusions, and renal failure requiring dialysis, and with a significantly higher rate of 30-day and 1-year mortality. The only identifiable independent predictor of major VC was female gender (hazard ratio HR: 2.31 95% confidence interval (CI): 1.08 to 4.98, p = 0.03). Major VC (HR: 2.31 95% CI: 1.20 to 4.43, p = 0.012), and renal disease at baseline (HR: 2.26 95% CI: 1.34 to 3.81, p = 0.002) were identified as independent predictors of 1-year mortality. Conclusions Major VC were frequent after TF-TAVR in the PARTNER trial using first-generation devices and were associated with high mortality. However, the incidence and impact of major VC on 1-year mortality decreased with lower-risk populations.
Bicuspid aortic stenosis accounts for almost 50% of patients undergoing surgical aortic valve replacement in the younger patients. Expanding the indication of transcatheter aortic valve replacement ...(TAVR) toward lower-risk and younger populations will lead to increased use of TAVR for patients with bicuspid aortic valve (BAV) stenosis despite the exclusion of bicuspid anatomy in all pivotal clinical trials.
This study sought to evaluate the association of BAV morphology and outcomes of TAVR with the new-generation devices.
Patients with BAV confirmed by central core laboratory computed tomography (CT) analysis were included from the international multicenter BAV TAVR registry. BAV morphology including the number of raphe, calcification grade in raphe, and leaflet calcium volume were assessed with CT analysis in a masked fashion. Primary outcomes were all-cause mortality at 1 and 2 years, and secondary outcomes included 30-day major endpoints and procedural complications.
A total of 1,034 CT-confirmed BAV patients with a mean age of 74.7 years and Society of Thoracic Surgeons score of 3.7% underwent TAVR with contemporary devices (n = 740 with Sapien 3; n = 188 with Evolut R/Pro; n = 106 with others). All-cause 30-day, 1-year, and 2-year mortality was 2.0%, 6.7%, and 12.5%, respectively. Multivariable analysis identified calcified raphe and excess leaflet calcification (defined as more than median calcium volume) as independent predictors of 2-year all-cause mortality. Both calcified raphe plus excess leaflet calcification were found in 269 patients (26.0%), and they had significantly higher 2-year all-cause mortality than those with 1 or none of these morphological features (25.7% vs. 9.5% vs. 5.9%; log-rank p < 0.001). Patients with both morphological features had higher rates of aortic root injury (p < 0.001), moderate-to-severe paravalvular regurgitation (p = 0.002), and 30-day mortality (p = 0.016).
Outcomes of TAVR in bicuspid aortic stenosis depend on valve morphology. Calcified raphe and excess leaflet calcification were associated with increased risk of procedural complications and midterm mortality. (Bicuspid Aortic Valve Stenosis Transcatheter Aortic Valve Replacement Registry; NCT03836521)
Display omitted