•This is an oil spill remote sensing update to 2014.•Latest findings from remote sensing of the U.S. Gulf spill are included.•Includes radar processing for the first time.•Includes summary of oil ...spill thickness remote sensing.
Remote-sensing for oil spills is reviewed. The use of visible techniques is ubiquitous, however it gives only the same results as visual monitoring. Oil has no particular spectral features that would allow for identification among the many possible background interferences. Cameras are only useful to provide documentation. In daytime oil absorbs light and remits this as thermal energy at temperatures 3–8K above ambient, this is detectable by infrared (IR) cameras.
Laser fluorosensors are useful instruments because of their unique capability to identify oil on backgrounds that include water, soil, weeds, ice and snow. They are the only sensor that can positively discriminate oil on most backgrounds. Radar detects oil on water by the fact that oil will dampen water-surface capillary waves under low to moderate wave/wind conditions. Radar offers the only potential for large area searches, day/night and foul weather remote sensing.
Light Detection and Ranging (LiDAR) technology has been widely used in forestry surveys in the form of airborne laser scanning (ALS), terrestrial laser scanning (TLS), and mobile laser scanning ...(MLS). The acquisition of important basic tree parameters (e.g., diameter at breast height and tree position) in forest inventory did not solve the problem of low measurement efficiency or weak GNSS signal under the canopy. A personal laser scanning (PLS) device combined with SLAM technology provides an effective solution for forest inventory under complex conditions with its light weight and flexible mobility. This study proposes a new method for calculating the volume of a cylinder using point cloud data obtained by a PLS device by fitting to a polygonal cylinder to calculate the diameter of the trunk. The point cloud data of tree trunks of different thickness were modeled using different fitting methods. The rate of correct tree trunk detection was 93.3% and the total deviation of the estimations of tree diameter at breast height (DBH) was -1.26 cm. The root mean square errors (RMSEs) of the estimations of the extracted DBH and the tree position were 1.58 cm and 26 cm, respectively. The survey efficiency of the personal laser scanning (PLS) device was 30m2/min for each investigator, compared with 0.91m2/min for the field survey. The test demonstrated that the PLS device combined with the SLAM algorithm provides an efficient and convenient solution for forest inventory.
Spatial light modulators are essential optical elements in applications that require the ability to regulate the amplitude, phase and polarization of light, such as digital holography, optical ...communications and biomedical imaging. With the push towards miniaturization of optical components, static metasurfaces are used as competent alternatives. These evolved to active metasurfaces in which light-wavefront manipulation can be done in a time-dependent fashion. The active metasurfaces reported so far, however, still show incomplete phase modulation (below 360°). Here we present an all-solid-state, electrically tunable and reflective metasurface array that can generate a specific phase or a continuous sweep between 0 and 360° at an estimated rate of 5.4 MHz while independently adjusting the amplitude. The metasurface features 550 individually addressable nanoresonators in a 250 × 250 μm
area with no micromechanical elements or liquid crystals. A key feature of our design is the presence of two independent control parameters (top and bottom gate voltages) in each nanoresonator, which are used to adjust the real and imaginary parts of the reflection coefficient independently. To demonstrate this array's use in light detection and ranging, we performed a three-dimensional depth scan of an emulated street scene that consisted of a model car and a human figure up to a distance of 4.7 m.
At the heart of the smartLAB, says project leader Sascha Beutel, who is at the Institute of Technical Chemistry of Leibniz University in Hanover, is a laboratory information system to which all lab ...components will be connected and controlled, from 'intelligent', self-cleaning lab benches to smart safety goggles that can project chemical safety information and augmente d-re ality displays. Sensors can monitor temperature, humidity, and carbon dioxide and oxygen levels, as well as vibration, light intensity and mass air flow.
Outcome data for patients receiving implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy-defibrillator (CRT-D) devices treated outside of clinical trials are lacking. No ...clinical trial has evaluated mortality after device implantation or after shock therapy in large numbers of patients with implanted devices that regularly transmit device data over a network.
Survival status in patients implanted with ICD and CRT devices across the United States from a single manufacturer was assessed. Outcomes were compared between patients followed in device clinic settings and those who regularly transmit remote data collected from the device an average of 4 times monthly. Shock delivery and electrogram analysis could be ascertained from patients followed on the network, enabling survival after ICD shock to be evaluated. One- and 5-year survival rates in 185,778 patients after ICD implantation were 92% and 68% and were 88% and 54% for CRT-D device recipients. In 8228 patients implanted with CRT-only devices, survival was 82% and 48% at 1 and 5 years, respectively. For the 69,556 ICD and CRT-D patients receiving remote follow-up on the network, 1- and 5-year survival rates were higher compared with those in the 116,222 patients who received device follow-up in device clinics only (50% reduction; P<0.0001). There were no differences between patients followed on or off the remote network for the characteristics of age, gender, implanted device year or type, and economic or educational status. Shock therapy was associated with subsequent mortality risk for both ICD and CRT-D recipients.
Survival after ICD and CRT-D implantation in patients treated in naturalistic practice compares favorably with survival rates observed in clinical trials. Remote follow-up of device data is associated with excellent survival, but arrhythmias that result in device therapy in this population are associated with a higher mortality risk compared with patients who do not require shock therapy.
Out-of-office blood pressure measurement is an essential part of diagnosing and managing hypertension. In the era of advanced digital health information technology, the approach to achieving this is ...shifting from traditional methods (ambulatory and home blood pressure monitoring) to wearable devices and technology. Wearable blood pressure monitors allow frequent blood pressure measurements (ideally continuous beat-by-beat monitoring of blood pressure) with minimal stress on the patient. It is expected that wearable devices will dramatically change the quality of detection and management of hypertension by increasing the number of measurements in different situations, allowing accurate detection of phenotypes that have a negative impact on cardiovascular prognosis, such as masked hypertension and abnormal blood pressure variability. Frequent blood pressure measurements and the addition of new features such as monitoring of environmental conditions allows interpretation of blood pressure data in the context of daily stressors and different situations. This new digital approach to hypertension contributes to anticipation medicine, which refers to strategies designed to identify increasing risk and predict the onset of cardiovascular events based on a series of data collected over time, allowing proactive interventions to reduce risk. To achieve this, further research and validation is required to develop wearable blood pressure monitoring devices that provide the same accuracy as current approaches and can effectively contribute to personalized medicine.
Recent technological advances in remote sensing sensors and platforms, such as high-resolution satellite imagers or unmanned aerial vehicles (UAV), facilitate the availability of fine-grained earth ...observation data. Such data reveal vegetation canopies in high spatial detail. Efficient methods are needed to fully harness this unpreceded source of information for vegetation mapping. Deep learning algorithms such as Convolutional Neural Networks (CNN) are currently paving new avenues in the field of image analysis and computer vision. Using multiple datasets, we test a CNN-based segmentation approach (U-net) in combination with training data directly derived from visual interpretation of UAV-based high-resolution RGB imagery for fine-grained mapping of vegetation species and communities. We demonstrate that this approach indeed accurately segments and maps vegetation species and communities (at least 84% accuracy). The fact that we only used RGB imagery suggests that plant identification at very high spatial resolutions is facilitated through spatial patterns rather than spectral information. Accordingly, the presented approach is compatible with low-cost UAV systems that are easy to operate and thus applicable to a wide range of users.
Asymptomatic atrial fibrillation (AF) is increasingly common in the aging population and implicated in many ischemic strokes. Earlier identification of AF with appropriate anticoagulation may ...decrease stroke morbidity and mortality.
We conducted a randomized controlled trial of AF screening using an AliveCor Kardia monitor attached to a WiFi-enabled iPod to obtain ECGs (iECGs) in ambulatory patients. Patients ≥65 years of age with a CHADS-VASc score ≥2 free from AF were randomized to the iECG arm or routine care (RC). iECG participants acquired iECGs twice weekly over 12 months (plus additional iECGs if symptomatic) onto a secure study server with overread by an automated AF detection algorithm and by a cardiac physiologist and/or consultant cardiologist. Time to diagnosis of AF was the primary outcome measure. The overall cost of the devices, ECG interpretation, and patient management were captured and used to generate the cost per AF diagnosis in iECG patients. Clinical events and patient attitudes/experience were also evaluated.
We studied 1001 patients (500 iECG, 501 RC) who were 72.6±5.4 years of age; 534 were female. Mean CHADS-VASc score was 3.0 (heart failure, 1.4%; hypertension, 54%; diabetes mellitus, 30%; prior stroke/transient ischemic attack, 6.5%; arterial disease, 15.9%; all CHADS-VASc risk factors were evenly distributed between groups). Nineteen patients in the iECG group were diagnosed with AF over the 12-month study period versus 5 in the RC arm (hazard ratio, 3.9; 95% confidence interval=1.4-10.4;
=0.007) at a cost per AF diagnosis of $10 780 (£8255). There was a similar number of stroke/transient ischemic attack/systemic embolic events (6 versus 10, iECG versus RC; hazard ratio=0.61; 95% confidence interval=0.22-1.69;
=0.34). The majority of iECG patients were satisfied with the device, finding it easy to use without restricting activities or causing anxiety.
Screening with twice-weekly single-lead iECG with remote interpretation in ambulatory patients ≥65 years of age at increased risk of stroke is significantly more likely to identify incident AF than RC over a 12-month period. This approach is also highly acceptable to this group of patients, supporting further evaluation in an appropriately powered, event-driven clinical trial.
URL: https://www.isrctn.com. Unique identifier: ISRCTN10709813.
The use of wireless sensor networks (WSN) in healthcare applications is growing in a fast pace. Numerous applications such as heart rate monitor, blood pressure monitor and endoscopic capsule are ...already in use. To address the growing use of sensor technology in this area, a new field known as wireless body area networks (WBAN or simply BAN) has emerged. As most devices and their applications are wireless in nature, security and privacy concerns are among major areas of concern. Due to direct involvement of humans also increases the sensitivity. Whether the data gathered from patients or individuals are obtained with the consent of the person or without it due to the need by the system, misuse or privacy concerns may restrict people from taking advantage of the full benefits from the system. People may not see these devices safe for daily use. There may also possibility of serious social unrest due to the fear that such devices may be used for monitoring and tracking individuals by government agencies or other private organizations. In this paper we discuss these issues and analyze in detail the problems and their possible measures.