NUK - logo
E-resources
Peer reviewed Open access
  • An Objective Methodology fo...
    Bonci, Tecla; Keogh, Alison; Del Din, Silvia; Scott, Kirsty; Mazzà, Claudia; On Behalf Of The Mobilise-D Consortium

    Sensors (Basel, Switzerland), 11/2020, Volume: 20, Issue: 22
    Journal Article

    Continuous monitoring by wearable technology is ideal for quantifying mobility outcomes in "real-world" conditions. Concurrent factors such as validity, usability, and acceptability of such technology need to be accounted for when choosing a monitoring device. This study proposes a bespoke methodology focused on defining a decision matrix to allow for effective decision making. A weighting system based on responses ( = 69) from a purpose-built questionnaire circulated within the IMI Mobilise-D consortium and its external collaborators was established, accounting for respondents' background and level of expertise in using wearables in clinical practice. Four domains (concurrent validity, CV; human factors, HF; wearability and usability, WU; and data capture process, CP), associated evaluation criteria, and scores were established through literature research and group discussions. While the CV was perceived as the most relevant domain (37%), the others were also considered highly relevant (WU: 30%, HF: 17%, CP: 16%). Respondents (~90%) preferred a hidden fixation and identified the lower back as an ideal sensor location for mobility outcomes. Overall, this study provides a novel, holistic, objective, as well as a standardized approach accounting for complementary aspects that should be considered by professionals and researchers when selecting a solution for continuous mobility monitoring.