E-resources
-
Margetić, Sandra; Ćelap, Ivana; Delić Brkljačić, Diana; Pavlović, Nikola; Šupraha Goreta, Sandra; Kobasić, Ivana; Lovrenčić-Huzjan, Arijana; Bašić Kes, Vanja
Biochemia Medica, 2020-Feb-15, Volume: 30, Issue: 1Journal Article, Paper
Clinical application of rivaroxaban and apixaban does not require therapeutic monitoring. Commercial anti-activated factor X (anti-FXa) inhibition methods for all anti-FXa drugs are based on the same principle, so there are attempts to evaluate potential clinical application of heparin-calibrated anti-FXa assay as an alternative method for direct FXa inhibitors. We aimed to evaluate relationship between anti-FXa methods calibrated with low molecular weight heparin (LMWH) and with drug specific calibrators, and to determine whether commercial LMWH anti-FXa assay can be used to exclude the presence of clinically relevant concentrations of rivaroxaban and apixaban. Low molecular weight heparin calibrated reagent (Siemens Healthineers, Marburg, Germany) was used for anti-FXa activity measurement. Innovance heparin (Siemens Healthineers, Marburg, Germany) calibrated with rivaroxaban and apixaban calibrators (Hyphen BioMed, Neuville-sur-Oise, France) was used for quantitative determination of FXa inhibitors. Analysis showed good agreement between LMWH calibrated and rivaroxaban calibrated activity (κ = 0.76) and very good agreement with apixaban calibrated anti-Xa activity (κ = 0.82), respectively. Low molecular weight heparin anti-FXa activity cut-off values of 0.05 IU/mL and 0.1 IU/mL are suitable for excluding the presence of clinically relevant concentrations (< 30 ng/mL) of rivaroxaban and apixaban, respectively. Concentrations above 300 ng/mL exceeded upper measurement range for LMWH anti-FXa assay and cannot be determined by this method. Low molecular weight heparin anti-FXa assay can be used in emergency clinical conditions for ruling out the presence of clinically relevant concentrations of rivaroxaban and apixaban. However, use of LMWH anti-FXa assay is not appropriate for their quantitative determination as an interchangeable method.
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.