Chen, Long Xiang; Xie, Mei Na; Zhao, Pan Pan; Wang, Feng Xiang; Hu, Peng; Wang, Dong Xiang
Applied energy, 01/2018, Volume: 210Journal Article
•A novel isobaric A-CAES system based on volatile fluid has been proposed.•Waste heat has employed to make IA-CAES more efficient and stable.•Proposed IA-CAES is more efficient and capacity than A-CAES.•CO2 is selected as volatile fluid for its environmentally properties and high saturation pressure.•Mixtures contain CO2 are investigated to enhance the working temperature range of IA-CAES. Adiabatic compressed air energy storage (A-CAES) is regarded as a promising and emerging storage technology with excellent power and storage capacity. Currently, efficiencies are approximately 70%, in part due to the issue of exergy losses during the throttling of compressed air. To increase the performance of the system, a novel isobaric adiabatic compressed air energy storage (IA-CAES) is proposed on the base of volatile fluid. The air storage vessel is divided into two parts by a piston, one part for air storage and the other has introduced into suitable volatile fluid. The waste heat is utilized to keep the volatile in a desirable pressure in discharging process, which impairs the effect of ambient temperature on pressure of volatile and makes the IA-CAES system stable. CO2 is selected as the pure volatile fluid own to its environmentally properties and high saturation pressure, while the IA-CAES system based on the CO2 can work in the mid and high latitudes only, due to its low critical temperature (304.13 K). 3 binary mixtures namely CO2/HC-600, CO2/HFC-32 and CO2/HFO-1234ze(E) are investigated to improve the critical temperature of CO2, trends to adapt to a wide range of ambient temperatures for IA-CAES system. The thermodynamic analysis including energy analysis, exergy analysis and the parametric analysis are evaluated by using steady-state mathematical model and thermodynamic laws. The calculations show, when CO2 is selected as the pure volatile fluid and the ambient temperature is higher than 288.15 K (15 °C), the average of total exergy efficiency (TEE) of IA-CAES improves more than 4% compared with that of A-CAES. When the waste heat is considered as free, the round trip efficiency (RTE) improved more than 6% and power capacity increased by more than 49% compared to the conventional A-CAES system. The CO2/HC-600 mixture with the compositions 0.85/0.15 has been proposed as the mixture volatile fluid. Compare with the conventional A-CAES system, the RTE and discharge time improved 6.26% and increased by 56.44%, respectively. Meanwhile, a parametric analysis is also carried out to evaluate the effects of several key parameters on the system performance of the IA-CAES systems.
Author
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.