Young, Melissa F; Raines, Kelley; Jameel, Farhad; Sidi, Manal; Oliveira-Streiff, Shaiana; Nwajei, Paula; McGlamry, Katherine; Ou, Jiangda; Oladele, Alawode; Suchdev, Parminder S
PloS one, 07/2021, Volume: 16, Issue: 7Journal Article
Anemia remains an important global health problem. Inexpensive, accurate, and noninvasive solutions are needed to monitor and evaluate anemia in resource-limited settings. We evaluated the performance of multiple point-of-care hemoglobin devices, including a novel noninvasive smartphone application tested on Apple® and Android® cell phones, Masimo Pronto®, and HemoCue® Hb-301 and Hb-801, against a gold-standard hematology analyzer (reference hemoglobin) using venous blood. We examined correlations between hemoglobin devices and reference hemoglobin, device accuracy (average bias, Bland-Altman plots, clinical performance) and classification bias (sensitivity, specificity) among 299 refugees (10mo-65y) in Atlanta, GA. Semi-structured interviews (n = 19) with participants and staff assessed usability and acceptability. Mean reference hemoglobin was 13.7 g/dL (SD:1.8) with 12.5% anemia. Noninvasive hemoglobin devices were not well correlated with reference hemoglobin (Apple® R.sup.2 = 0.08, Android® R.sup.2 = 0.11, Masimo Pronto® R.sup.2 = 0.29), but stronger correlations were reported with HemoCue® Hb-301 (R.sup.2 = 0.87) and Hb-801 (R.sup.2 = 0.88). Bias (SD) varied across each device: Apple®: -1.6 g/dL (2.0), Android®: -0.7 g/dL (2.0), Masimo Pronto®: -0.4 g/dL (1.6), HemoCue® Hb-301: +0.4 g/dL (0.7) and HemoCue® Hb-801: +0.2 g/dL (0.6). Clinically acceptable performance (within ± 1 g/dL of reference hemoglobin) was higher for the invasive devices (HemoCue® Hb-301: 90.3%; HemoCue® Hb-801: 93.4%) compared to noninvasive devices (Apple®: 31.5%; Android®: 34.6%; Masimo Pronto®: 49.5%). Sensitivity and specificity were 63.9% and 48.2% for Apple®, 36.1% and 67.6% for Android®, 45.7% and 85.3% for Masimo Pronto®, 54.3% and 97.6% for HemoCue® Hb-301, and 66.7% and 97.6% for HemoCue® Hb-801. Noninvasive devices were considered easy to use and were the preferred method by participants. Among the only studies to compare multiple point-of-care approaches to hemoglobin testing, the diagnostic ability of HemoCue® was comparable to reference hemoglobin, while noninvasive devices had high user acceptability but considerable biases. Improvements in noninvasive device performance and further testing in anemic populations are recommended before broader use.
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
Year | Impact factor | Edition | Category | Classification | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
Database name | Field | Year |
---|
Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
---|
Source: Personal bibliographies
and: SICRIS
The material is available in full text. If you wish to order the material anyway, click the Continue button.