Narodna in univerzitetna knjižnica, Ljubljana (NUK)
-
The effects of normobaric and hyperbaric oxygenation on MRI signal intensities in T1-weighted, T2-weighted and FLAIR images in human brainVelej, Vida ; Cankar, Ksenija, 1965- ; Vidmar, Jernej, 1979-Dissolved oxygen has known paramagnetic effects in magnetic resonance imaging (MRI). The aim ofthis study was to compare the effects of normobaric oxygenation (NBO) and hyperbaric oxygenation (HBO) ... on hu-man brain MRI signal intensities.Patients and methods. Baseline brain MRI was performed in 17 healthy subjects (mean age 27.8 ± 3.2). MRI wasrepeated after exposure to the NBO and HBO at different time points (0 min, 25 min, 50 min). Signal intensities in T1-weighted, T2-weighted images and fluid attenuated inversion recovery (FLAIR) signal intensities of several intracranialstructures were compared between NBO and HBO.Results. Increased T1-weighted signal intensities were observed in white and deep grey brain matter, cerebrospinalfluid (CSF), venous blood and vitreous body after exposure to NBO as well as to HBO compared to baseline (Dunnett’stest, p < 0.05) without significant differences between both protocols. There was also no significant difference in T2-weighted signal intensities between NBO and HBO. FLAIR signal intensities were increased only in the vitreous bodyafter NBO and HBO and FLAIR signal of caudate nucleus was decreased after NBO (Dunnett’s test, p < 0.05). Thestatistically significant differences in FLAIR signal intensities were found between NBO and HBO (paired t-test, p < 0.05)in most observed brain structures (paired t-test, p < 0.05).Conclusions. Our results show that NBO and HBO alters signal intensities T1-weighted and FLAIR images of humanbrain. The differences between NBO and HBO are most pronounced in FLAIR imaging.Vir: Radiology and oncology. - ISSN 1318-2099 (Vol. 57, no. 3, 2023, str. 317-324)Vrsta gradiva - članek, sestavni del ; neleposlovje za odrasleLeto - 2023Jezik - angleškiCOBISS.SI-ID - 171909123
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|---|
Velej, Vida | 53139 |
Cankar, Ksenija, 1965- | 15243 |
Vidmar, Jernej, 1979- | 28490 |
Vir: Osebne bibliografije
in: SICRIS
Izberite prevzemno mesto:
Prevzem gradiva po pošti
Naslov za dostavo:
Med podatki člana manjka naslov.
Storitev za pridobivanje naslova trenutno ni dostopna, prosimo, poskusite še enkrat.
S klikom na gumb "V redu" boste potrdili zgoraj izbrano prevzemno mesto in dokončali postopek rezervacije.
S klikom na gumb "V redu" boste potrdili zgoraj izbrano prevzemno mesto in naslov za dostavo ter dokončali postopek rezervacije.
S klikom na gumb "V redu" boste potrdili zgoraj izbrani naslov za dostavo in dokončali postopek rezervacije.
Obvestilo
Trenutno je storitev za avtomatsko prijavo in rezervacijo nedostopna. Gradivo lahko rezervirate sami na portalu Biblos ali ponovno poskusite tukaj kasneje.
Gesla v Splošnem geslovniku COBISS
Izbira mesta prevzema
Gradivo iz matične enote je brezplačno. Če je gradivo na mesto prevzema dostavljeno iz drugih enot, lahko knjižnica to storitev zaračuna.
Mesto prevzema | Status gradiva | Rezervacija |
---|
Rezervacija v teku
Prosimo, počakajte trenutek.
Rezervacija je uspela.
Rezervacija ni uspela.
Rezervacija...
Članska izkaznica:
Mesto prevzema:
Naročanje gradiva za izposojo v čitalnice
Naročanje kopij člankov
Urnik dostave gradiva z oznako DS v signaturi