The introduction of human immunodeficiency virus (HIV) antibody rapid testing (RT) in resource-limited settings has proven to be a successful intervention to increase access to prevention measures ...and improve timely linkage to care. However, the quality of testing has not always kept pace with the scale-up of this testing strategy. To monitor the accuracy of HIV RT test results, a national proficiency testing (PT) program was rolled out at selected testing sites in Ghana using the dried tube specimen (DTS) approach. Between 2015 and 2018, 635 HIV testing sites, located in five regions and supported by the U.S. President's Emergency Plan for AIDS Relief (PEPFAR), were enrolled in the HIV PT program of the Ghana Health Service National AIDS/STI Control Programme. These sites offered various services: HIV Testing and Counselling (HTC), prevention of mother-to-child transmission (PMTCT) and Antiretroviral Treatment (ART). The PT panels, composed of six DTS, were prepared by two regional laboratories, using fully characterized plasma obtained from the regional blood banks and distributed to the testing sites. The results were scored by the PT providers according to the predefined acceptable performance criteria which was set at greater than or equal to 95%. Seven rounds of PT panels were completed successfully over three years. The number of sites enrolled increased from 205 in round 1 (June 2015) to 635 in round 7 (December 2018), with a noticeable increase in Greater Accra and Eastern regions. The average participation rates of enrolled sites ranged from 88.0% to 98.0% across the PT rounds. By round 7, HTC (257/635 (40.5%)) and PMTCT (237/635 (37.3%)) had a larger number of sites that participated in the PT program than laboratory (106/635 (16.7%)) and ART (12/635 (1.9%)) sites. The average testing performance rate improved significantly from 27% in round 1 to 80% in round 7 (p < 0.001). The highest performance rate was observed for ART (100%), HTC (92%), ANC/PMTCT (90%) and Laboratory (89%) in round 5. The DTS PT program showed a significant increase in the participation and performance rates during this period. Sub-optimal performances observed was attributed to non-compliance to the national testing algorithm and testing technique. However, the implementation of review meetings, peer-initiated corrective action, supportive supervisory training, and mentorship proved impactful. The decentralized approach to preparing the PT panels ensured ownership by the region and districts.
Tests for recent HIV infection (TRI) distinguish recent from long-term HIV infections using markers of antibody maturation. The limiting antigen avidity enzyme immunoassay (LAg EIA) is widely used ...with HIV viral load (VL) in a recent infection testing algorithm (RITA) to improve classification of recent infection status, estimate population-level HIV incidence, and monitor trends in HIV transmission. A novel rapid test for recent HIV infection (RTRI), Asanté™, can determine HIV serostatus and HIV recency within minutes on a lateral flow device through visual assessment of test strip or reader device. We conducted a field-based laboratory evaluation of the RTRI among pregnant adolescent girls and young women (AGYW) attending antenatal clinics (ANC) in Malawi.We enrolled pregnant AGYW aged <25 years testing HIV-positive for the first time at their first ANC visit from 121 ANCs in four high-HIV burden districts. Consenting participants provided blood for recency testing using LAg EIA and RTRI, which were tested in central laboratories. Specimens with LAg EIA normalized optical density values ≤2.0 were classified as probable recent infections. RTRI results were based on: (1) visual assessment: presence of a long-term line (LT) indicating non-recent infection and absence of the line indicating recent infection; or (2) a reader; specimens with LT line intensity units <3.0 were classified as probable recent infections. VL was measured for specimens classified as a probable recent infections by either assay; those with HIV-1 RNA ≥1,000 copies/mL were classified as confirmed recent infections. We evaluated the performance of the RTRI by calculating correlation between RTRI and LAg EIA results, and percent agreement and kappa between RTRI and LAg EIA RITA results.Between November 2017 to June 2018, 380 specimens were available for RTRI evaluation; 376 (98.9%) were confirmed HIV-positive on RTRI. Spearman's rho between RTRI and LAg EIA was 0.72 indicating strong correlation. Percent agreement and kappa between RTRI- and LAg EIA-based RITAs were >90% and >0.65 respectively indicating substantial agreement between the RITAs.This was the first field evaluation of an RTRI in sub-Saharan Africa, which demonstrated good performance of the assay and feasibility of integrating RTRI into routine HIV testing services for real-time surveillance of recent HIV infection.
Background The introduction of human immunodeficiency virus (HIV) antibody rapid testing (RT) in resource-limited settings has proven to be a successful intervention to increase access to prevention ...measures and improve timely linkage to care. However, the quality of testing has not always kept pace with the scale-up of this testing strategy. To monitor the accuracy of HIV RT test results, a national proficiency testing (PT) program was rolled out at selected testing sites in Ghana using the dried tube specimen (DTS) approach. Methods Between 2015 and 2018, 635 HIV testing sites, located in five regions and supported by the U.S. President’s Emergency Plan for AIDS Relief (PEPFAR), were enrolled in the HIV PT program of the Ghana Health Service National AIDS/STI Control Programme. These sites offered various services: HIV Testing and Counselling (HTC), prevention of mother-to-child transmission (PMTCT) and Antiretroviral Treatment (ART). The PT panels, composed of six DTS, were prepared by two regional laboratories, using fully characterized plasma obtained from the regional blood banks and distributed to the testing sites. The results were scored by the PT providers according to the predefined acceptable performance criteria which was set at ≥ 95%. Results Seven rounds of PT panels were completed successfully over three years. The number of sites enrolled increased from 205 in round 1 (June 2015) to 635 in round 7 (December 2018), with a noticeable increase in Greater Accra and Eastern regions. The average participation rates of enrolled sites ranged from 88.0% to 98.0% across the PT rounds. By round 7, HTC (257/635 (40.5%)) and PMTCT (237/635 (37.3%)) had a larger number of sites that participated in the PT program than laboratory (106/635 (16.7%)) and ART (12/635 (1.9%)) sites. The average testing performance rate improved significantly from 27% in round 1 to 80% in round 7 (p < 0.001). The highest performance rate was observed for ART (100%), HTC (92%), ANC/PMTCT (90%) and Laboratory (89%) in round 5. Conclusion The DTS PT program showed a significant increase in the participation and performance rates during this period. Sub-optimal performances observed was attributed to non-compliance to the national testing algorithm and testing technique. However, the implementation of review meetings, peer-initiated corrective action, supportive supervisory training, and mentorship proved impactful. The decentralized approach to preparing the PT panels ensured ownership by the region and districts.
The corona virus disease 19 pandemic has affected the whole world with pregnant ladies being more vulnerable population. This study aimed to evaluate characteristics of corona virus disease 19 ...infection in pregnancy and neonates and whether close proximity to the mother increases the incidence of corona virus disease infection in neonates..
This is a hospital based prospective cross sectional observational study done among pregnant women presenting to Paropakar maternity and womens hospital from 1st September 2020 to 31st march 2021 with confirmed corona virus disease 19 infection.
The total 160 cases were included in study. Most of the women (33.8%) were of 20- 25 years of age, 55 % were multigravida and 77.6 % were full term. Around 74 % of cases were symptomatic with predominant symptoms being cough, fever and sore throat present in 33.1 %, 18% and 14% respectively. Out of 125 deliveries 71 % of cases underwent cesarean section of which fetal distress was most common indication. Six newborns were positive for corona virus disease 19 infection within 48 hours of life. Mortality was seen in four mothers and three neonates.
The clinical presentation of corona virus disease infection in pregnant ladies is similar to general population. There is no increased risk of vertical transmission to the baby.