The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this ...technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number-violating process: ^{130}Te neutrinoless double-beta decay. Examining a total TeO_{2} exposure of 86.3 kg yr, characterized by an effective energy resolution of (7.7±0.5) keV FWHM and a background in the region of interest of (0.014±0.002) counts/(keV kg yr), we find no evidence for neutrinoless double-beta decay. Including systematic uncertainties, we place a lower limit on the decay half-life of T_{1/2}^{0ν}(^{130}Te)>1.3×10^{25} yr (90% C.L.); the median statistical sensitivity of this search is 7.0×10^{24} yr. Combining this result with those of two earlier experiments, Cuoricino and CUORE-0, we find T_{1/2}^{0ν}(^{130}Te)>1.5×10^{25} yr (90% C.L.), which is the most stringent limit to date on this decay. Interpreting this result as a limit on the effective Majorana neutrino mass, we find m_{ββ}<(110-520) meV, where the range reflects the nuclear matrix element estimates employed.
The possibility that neutrinos may be their own antiparticles, unique among the known fundamental particles, arises from the symmetric theory of fermions proposed by Ettore Majorana in 1937
. Given ...the profound consequences of such Majorana neutrinos, among which is a potential explanation for the matter-antimatter asymmetry of the universe via leptogenesis
, the Majorana nature of neutrinos commands intense experimental scrutiny globally; one of the primary experimental probes is neutrinoless double beta (0νββ) decay. Here we show results from the search for 0νββ decay of
Te, using the latest advanced cryogenic calorimeters with the CUORE experiment
. CUORE, operating just 10 millikelvin above absolute zero, has pushed the state of the art on three frontiers: the sheer mass held at such ultralow temperatures, operational longevity, and the low levels of ionizing radiation emanating from the cryogenic infrastructure. We find no evidence for 0νββ decay and set a lower bound of the process half-life as 2.2 × 10
years at a 90 per cent credibility interval. We discuss potential applications of the advances made with CUORE to other fields such as direct dark matter, neutrino and nuclear physics searches and large-scale quantum computing, which can benefit from sustained operation of large payloads in a low-radioactivity, ultralow-temperature cryogenic environment.
•A large custom cryogen-free cryostat has been designed and built in order to operate the CUORE detector.•The CUORE cryostat has a 1 m3 experimental volume and is able to host a tonne-scale ...bolometric detector.•The CUORE cryostat guarantees a low noise and low radioactivity environment, needed to search for 0nbb.•The CUORE detector has been cooled down to 8.3 mK and steadily operated at 15 mK, proving the success of the cryostat.
The CUORE experiment is the world’s largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso, Italy, searching for the neutrinoless double beta decay of 130Te. A large custom cryogen-free cryostat allows reaching and maintaining a base temperature of ∼10 mK, required for the optimal operation of the detector. This apparatus has been designed in order to achieve a low noise environment, with minimal contribution to the radioactive background for the experiment. In this paper, we present an overview of the CUORE cryostat, together with a description of all its sub-systems, focusing on the solutions identified to satisfy the stringent requirements. We briefly illustrate the various phases of the cryostat commissioning and highlight the relevant steps and milestones achieved each time. Finally, we describe the successful cooldown of CUORE.
The projected background for the CUORE experiment Alduino, C.; Avignone, F. T.; Azzolini, O. ...
The European physical journal. C, Particles and fields,
08/2017, Letnik:
77, Številka:
8
Journal Article
Recenzirano
Odprti dostop
The Cryogenic Underground Observatory for Rare Events (CUORE) is designed to search for neutrinoless double beta decay of
130
Te with an array of 988 TeO
2
bolometers operating at temperatures ...around 10 mK. The experiment is currently being commissioned in Hall A of Laboratori Nazionali del Gran Sasso, Italy. The goal of CUORE is to reach a 90% C.L. exclusion sensitivity on the
130
Te decay half-life of 9
×
10
25
years after 5 years of data taking. The main issue to be addressed to accomplish this aim is the rate of background events in the region of interest, which must not be higher than 10
-
2
counts/keV/kg/year. We developed a detailed Monte Carlo simulation, based on results from a campaign of material screening, radioassays, and bolometric measurements, to evaluate the expected background. This was used over the years to guide the construction strategies of the experiment and we use it here to project a background model for CUORE. In this paper we report the results of our study and our expectations for the background rate in the energy region where the peak signature of neutrinoless double beta decay of
130
Te is expected.
We report on the measurement of the two-neutrino double-beta decay half-life of Formula omittedTe with the CUORE-0 detector. From an exposure of 33.4 kg year of TeO Formula omitted, the half-life is ...determined to be Formula omitted = 8.2 ± 0.2 (stat.) ± 0.6 (syst.) Formula omitted 10 Formula omitted year. This result is obtained after a detailed reconstruction of the sources responsible for the CUORE-0 counting rate, with a specific study of those contributing to the Formula omittedTe neutrinoless double-beta decay region of interest.
The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this ...technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number-violating process: 130Te neutrinoless double-beta decay. Examining a total TeO2 exposure of 86.3 kg yr, characterized by an effective energy resolution of ( 7.7 ± 0.5 ) keV FWHM and a background in the region of interest of ( 0.014 ± 0.002 ) counts / ( keV kg yr ) , we find no evidence for neutrinoless double-beta decay. Including systematic uncertainties, we place a lower limit on the decay half-life of T0ν1/2 ( 130Te ) > 1.3 × 1025 yr (90% C.L.); the median statistical sensitivity of this search is 7.0 × 1024 yr. Combining this result with those of two earlier experiments, Cuoricino and CUORE-0, we find T0ν1/2 ( 130Te ) > 1.5 × 1025 yr (90% C.L.), which is the most stringent limit to date on this decay. Interpreting this result as a limit on the effective Majorana neutrino mass, we find mββ < ( 110 − 520 ) meV , where the range reflects the nuclear matrix element estimates employed.
The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this ...technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number-violating process: 130Te neutrinoless double-beta decay. Examining a total TeO2 exposure of 86.3 kg yr, characterized by an effective energy resolution of (7.7 ± 0.5) keV FWHM and a background in the region of interest of (0.014 ± 0.002) counts / (keV kg yr), we find no evidence for neutrinoless double-beta decay. Including systematic uncertainties, we place a lower limit on the decay half-life of T0ν1/2 (130Te) > 1.3 × 1025 yr (90% C.L.); the median statistical sensitivity of this search is 7.0 × 10 24 yr . Combining this result with those of two earlier experiments, Cuoricino and CUORE-0, we find T0ν1/2 (130Te) > 1.5 × 1025 yr (90% C.L.), which is the most stringent limit to date on this decay. Interpreting this result as a limit on the effective Majorana neutrino mass, we find mββ < (110 − 520) meV, where the range reflects the nuclear matrix element estimates employed.
We describe the performance of high bandwidth-density silicon photonic based integrated circuits (SiPh ICs) that enable the first fully functional photonic engine (PE) module co-packaged with an ...Ethernet switch. We demonstrate the 1.6 Tbps SiPh transmitter (Tx) IC that integrates on-die all the lasers, micro ring modulators, monitor photodetectors, spot size converters, and V-grooves that are needed to support sixteen 106.25 Gbps PAM4 optical transmit channels. This SiPh Tx, together with discrete receiver (Rx) SiPh ICs, enabled an 800 Gbps PE. The PE is designed to allow up to sixteen modules to be co-packaged around a high-bandwidth switch ASIC. The PE test results described in this article were obtained using sixteen 53.125 Gbps electrical channels that were multiplexed to drive eight simultaneously operating 106.25 Gbps optical channels. We report DR4 IEEE standards compliant high-speed optical eye performance as well as full link operation. Post-FEC error-free operation over temperature and over extended time duration is demonstrated on all channels.
Low energy analysis techniques for CUORE Alduino, C.; Avignone, F. T.; Azzolini, O. ...
The European physical journal. C, Particles and fields,
12/2017, Letnik:
77, Številka:
12
Journal Article
Recenzirano
Odprti dostop
CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of
130
Te. ...CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searches requires improving the energy threshold to 10 keV. In this paper, we describe the analysis techniques developed for the low energy analysis of CUORE-like detectors, using the data acquired from November 2013 to March 2015 by CUORE-0, a single-tower prototype designed to validate the assembly procedure and new cleaning techniques of CUORE. We explain the energy threshold optimization, continuous monitoring of the trigger efficiency, data and event selection, and energy calibration at low energies in detail. We also present the low energy background spectrum of CUORE-0 below
60
keV
. Finally, we report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0 energy threshold and background, as well as an estimate of the uncertainty on the nuclear quenching factor from nuclear recoils inCUORE-0.