First results from the CUORE experiment Alduino, C.; Alfonso, K.; Bari, G. ...
Journal of physics. Conference series,
01/2020, Letnik:
1342, Številka:
1
Journal Article
Recenzirano
Odprti dostop
CUORE (Cryogenic Underground Observatory for Rare Events) is a ton-scale experiment aiming to the search of neutrino-less double beta decay in 130Te with a projected sensitivity on the Majorana ...effective mass close to the inverted hierarchy region. The CUORE detector consists of a segmented array of 988 TeO2 bolometers, organized in 19 towers and operated at a temperature of about 10 mK thanks to a custom cryogenic system which, besides the uncommon scale, observes several constraints from the radio-purity of the materials to the mechanical decoupling of the cooling systems. The successful commissioning of the CUORE cryogenic system has been completed early in 2016 and represents an outstanding achievement by itself. The installation of the detector proceeded along 2016 followed by the cooldown to base temperature at the beginning of 2017. The CUORE detector is now operational and has been taking science data since Spring 2017. With the first ~3 weeks of collected data, we present here the most stringent constraint on the 130Te half-live for the neutrino-less double beta decay.
CUORE is a tonne-scale cryogenic experiment located at the Laboratori Nazionali del Gran Sasso that exploits bolometric technique to search for neutrinoless double beta decay of 130Te. Thanks to its ...very low background and large mass, CUORE is also a powerful tool to study a broad class of phenomena, such as solar axions and WIMP scattering. The ability to conduct such sensitive searches crucially depends on the energy threshold, which has to be kept as low as possible. In this contribution, we show how the trigger algorithm affects the sensitivity to low-energy phenomena and the interpretation of the energy spectrum. In particular, we focus on the impact that the trigger algorithm has on the identification of the coincidence events among different crystals and, consequently, on the reconstruction of the background.
Initial performance of the CUORE detector Cushman, J. S.; Alduino, C.; Alfonso, K. ...
Journal of physics. Conference series,
01/2020, Letnik:
1342, Številka:
1
Journal Article
Recenzirano
Odprti dostop
CUORE, the Cryogenic Underground Observatory for Rare Events, is an experiment searching for the neutrinoless double-beta decay of 130Te. The first CUORE dataset was acquired in May and June 2017 and ...consisted of 10.6 kg-yr of TeO2 exposure, with several days of calibration data before and after the physics dataset. We discuss here the initial performance of the CUORE detector and cryostat in this first dataset.
The Cryogenic Underground Observatory for Rare Events (CUORE) at Laboratori Nazionali del Gran Sasso of INFN in Italy is an experiment searching for neutrinoless double beta (0νββ) decay. Its main ...goal is to investigate this decay in ^{130}Te, but its ton-scale mass and low background make CUORE sensitive to other rare processes as well. In this Letter, we present our first results on the search for 0νββ decay of ^{128}Te, the Te isotope with the second highest natural isotopic abundance. We find no evidence for this decay, and using a Bayesian analysis we set a lower limit on the ^{128}Te 0νββ decay half-life of T_{1/2}>3.6×10^{24} yr (90% CI). This represents the most stringent limit on the half-life of this isotope, improving by over a factor of 30 the previous direct search results, and exceeding those from geochemical experiments for the first time.
Status and prospects for CUORE Canonica, L; Alduino, C; Alfonso, K ...
Journal of Physics. Conference Series (Online),
09/2017, Letnik:
888, Številka:
1
Journal Article, Conference Proceeding
Recenzirano
Odprti dostop
CUORE is a cryogenic detector consisting of 988 TeO2 crystals, 750 g each, and will be operated at a temperature of ∼10 mK, to search for neutrinoless double beta decay (0νββ) of 130Te. The detector, ...in the final stages of construction at the Laboratori Nazionali del Gran Sasso (Italy), will start its operations in 2016. CUORE-0, its pilot experiment, has proven the feasibility of CUORE, demonstrating that the target background of 0.01 counts/keV/kg/y and the energy resolution of 5 keV are within reach. CUORE-0 also made the most precise measurement of the 2νββ decay. The expected sensitivity of CUORE to the 0νββ 130Te half-life is 9 ·1025y, for 5 years of data taking. Here, we report the most recent results of CUORE-0, their implications for CUORE, and the current status of the CUORE experiment.
The CUORE and CUORE-0 experiments at LNGS Alduino, C; Alfonso, K; Avignone, F T ...
Journal of physics. Conference series,
07/2018, Letnik:
1056, Številka:
1
Journal Article
Recenzirano
Odprti dostop
The Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment searching for neutrinoless double beta decay that has been able to reach the 1-ton scale. The detector ...consists of an array of 988 TeO2 crystals arranged in a cylindrical compact structure of 19 towers. The construction of the experiment and, in particular, the installation of all towers in the cryostat was completed in August 2016 and commissioning started in fall 2016. The experiment has completed the pre-operation phase and is currently in data taking. We present here the achievements of CUORE during the commissioning phase and the limit on the 130Te half-life for the neutrinoless double beta decay that has been released after the first 3 weeks of collected data. Physics results from CUORE-0 will also be updated.
The Cryogenic Underground Observatory for Rare Events (CUORE) will search for the 0vββ decay in 130Te using a cryogenic array of TeO2 bolometers, operated at a base temperature of ~10mK. CUORE will ...consist of a closely packed array of 19 towers each containing 52 crystals, for a total mass of 741kg. The detector assembly is hosted in one of the largest cryostats ever constructed and will be cooled down to base temperature using a custom-built cryogen free dilution refrigerator. The CUORE cryostat along with the pulse tube based dilution refrigerator has been already commissioned at Laboratori Nazionali del Gran Sasso (LNGS) and a record base temperature, on a cubic meter scale, of ~6mK was achieved during one of the integration runs. We present the results from integration runs, characterizing the system and the cooling performance of the dilution refrigerator, effectively showcasing its stability at base temperature for the expected thermal load.
Lowering the CUORE energy threshold Alduino, C.; Alfonso, K.; Artusa, D. R. ...
Journal of physics. Conference series,
09/2017, Letnik:
888, Številka:
1
Journal Article
Recenzirano
Odprti dostop
The Cryogenic Underground Observatory for Rare Events (CUORE) is a ton-scale double beta decay experiment based on TeO2 cryogenic bolometers and is currently in the last construction stage at the ...Gran Sasso National Laboratory (LNGS). Its primary goal is to observe neutrino-less double beta decay of 130Te, however thanks to the ultra-low background and large projected exposure it could also be suitable for other rare event searches, as the detection of solar axions, neutrinos from type II supernovae or direct detection of dark matter. The sensitivity for these searches will depend on the performance achieved at the low energy threshold. For this reason a trigger algorithm based on continuous data filtering has been developed which will allow lowering the threshold down to the few keV region. The new trigger has been tested in CUORE-0, a single-tower CUORE prototype consisting of 52 TeO2 bolometers and recently concluded, and here we present the results in terms of trigger efficiency, data selection and low-energy calibration.
We report new results from the search for neutrinoless double-beta decay in ^{130} Te with the CUORE detector. This search benefits from a fourfold increase in exposure, lower trigger thresholds, and ...analysis improvements relative to our previous results. We observe a background of (1.38±0.07)×10^{-2} counts/(keV kg yr)) in the 0νββ decay region of interest and, with a total exposure of 372.5 kg yr, we attain a median exclusion sensitivity of 1.7×10^{25} yr. We find no evidence for 0νββ decay and set a 90% credibility interval Bayesian lower limit of 3.2×10^{25} yr on the ^{130} Te half-life for this process. In the hypothesis that 0νββ decay is mediated by light Majorana neutrinos, this results in an upper limit on the effective Majorana mass of 75-350 meV, depending on the nuclear matrix elements used.