We present two cases of failure of balloon inflation secondary to balloon separation from the delivery catheter when implanting the SAPIEN 3 transcatheter heart valve (Edwards Lifesciences, Irvine, ...CA, USA). Although very uncommon, this is a potentially disastrous complication of transcatheter intervention. Case 1 highlights the complexity of the problem when it occurs and subsequent complications. Case 2 highlights how to manage this issue successfully.
•Failure of Sapien 3 deployment may result from malfunction of the delivery balloon.•We report 2 cases of THV failure due to balloon separation from the delivery catheter.•The complications of interrupted deployment are discussed.•The optimal technique for removal of the valve from the body is detailed.
The Art of the Seal Arunothayaraj, Sandeep; Palmer, Sonny; Whitbourn, Robert
JACC. Cardiovascular interventions,
06/2021, Letnik:
14, Številka:
11
Journal Article
Bifurcation coronary artery disease is common as the development of atherosclerosis is facilitated by altered endothelial shear stress. Multiple anatomical and physiological factors need to be ...considered when treating bifurcation lesions. To achieve optimal results, various stenting techniques have been developed, each with benefits and limitations. In this state-of-the-art review we describe technically important characteristics of bifurcation lesions and summarise the evidence supporting contemporary bifurcation techniques.
Transcatheter aortic valve implantation (TAVI) with commissural alignment aims to limit the risk of coronary occlusion and maintain good coronary access. However, due to coronary origin eccentricity ...within the coronary cusp, coronary-commissural overlap (CCO) may still occur. TAVI using coronary alignment, rather than commissural alignment, may further improve coronary access. To compare rates of CCO after TAVI using commissural versus coronary alignment methodology. Cardiac CT scans from 102 patients with severe (tricuspid) aortic stenosis referred for TAVI were analysed. Native cusp asymmetry and coronary eccentricity were defined and used to simulate TAVI using commissural versus coronary alignment. Rates of optimal coronary alignment (< 10° from cusp centre) and severe misalignment (< 15° from coronary-commissural overlap) were compared. Additionally, the impact of valve misalignment during implantation was assessed. The native right coronary artery (RCA) origin was 15.8° (9.5 to 24°) closer to the right coronary cusp/non-coronary cusp (RCC-NCC) commissure than the centre of the right coronary cusp. The native left coronary artery (LCA) origin was 4.5° (0 to 11.5°) closer to the left coronary cusp/non-coronary cusp (LCC-NCC) commissure than the centre of the left coronary cusp (
p
< 0.01). Compared to commissural alignment, coronary alignment doubled the proportion of optimally-aligned RCAs (62/102 60.8% vs. 31/102 30.4%;
p
< 0.001), without a significant change in optimal LCA alignment (62/102 60.8% vs. 74/102 72.6%;
p
= 0.07). There were no cases of severe misalignment with either strategy. Simulating 15° of valve misalignment resulted in severe RCA compromise risk in 7/102 (6.9%) of commissural alignment cases, compared to none using coronary alignment. Fluoroscopic projection was similar with both approaches. Coronary alignment resulted in a 2-fold increase of optimal TAVI positioning relative to the RCA ostium when compared to commissural alignment without impacting the LCA. Use of coronary alignment rather than commissural alignment may improve coronary access after TAVI and is less sensitive to valve rotational error, particularly for the right coronary artery.
Graphical Abstract
Right bundle-branch block (RBBB) is a strong predictor of the development of high-grade AV block (AVB) after TAVI.
To assess mortality, length-of-hospital stay, and cost in patients with RBBB ...undergoing TAVI according to whether or not they had preprocedural permanent pacemaker (PPM) implantation.
A total of 121 patients with RBBB who underwent TAVI between 2009-2021 were included. A total of 41 patients (33.9%) received a prophylactic PPM by clinical preference and 45/80 patients (56%) received PPM after TAVI. Baseline characteristics were balanced. Mortality was similar at 5 years, with death in 17 patients (41.4%) in the prophylactic PPM group vs 27 (33.8%) in the no prophylactic PPM group (adjusted hazard ratio HR, 1.27; 95% confidence interval CI, 0.69-2.33; P=.44). Median survival for the prophylactic PPM (4.2 years), post TAVI PPM (4.5 years) and no pacemaker (4.7 years) groups was similar. Sixteen deaths (35.6%) occurred in those receiving PPM after TAVI and 11 deaths (31.4%) occurred in those not receiving PPM (HR, 0.95; 95% CI, 0.43-2.09; P=.90). Thirty-day all-cause mortality was similar. Compared with post-TAVI PPM, prophylactic PPM reduced hospital length of stay (4.3 ± 4.5 days vs 2.5 ± 1.6 days, respectively; P=.02). For the highest and lowest complication and comorbidity scores, prophylactic PPM resulted in cost savings of £297.32 (-2.9%) and excess cost of £423.89 (+5.6%), respectively. There were no major pacing-related complications.
More than half of patients with RBBB undergoing TAVI require PPM shortly after their valve implant. A prophylactic pacing strategy is safe, reduces length of hospital stay, and is cost effective in the United Kingdom.