Background. Epidural spinal electrical stimulation at the lumbar spinal level evokes rhythmic muscle activation of lower-limb antagonists, attributed to the central pattern generator. However, the ...efficacy of noninvasive spinal stimulation for the activation of lower-limb muscles is not yet clear. This review aimed to analyze the feasibility and efficacy of noninvasive transcutaneous spinal cord stimulation (tSCS) on motor function in individuals with spinal cord injury. Methods. A search for tSCS studies was made of the following databases: PubMed; Cochrane Registry; and Physiotherapy Evidence Database (PEDro). In addition, an inverse manual search of the references cited by the identified articles was carried out. The keywords transcutaneous, non-invasive, electrical stimulation, spinal cord stimulation Mesh term, and spinal cord injury were used. Results. A total of 352 articles were initially screened, of which 13 studies met the inclusion criteria for systematic review. The total participant sample comprised 55 persons with spinal cord injury. All studies with tSCS provided evidence of induced muscle activation in the lower and upper limbs, and applied stimulation at the level of the T11-T12 and C4-C7 interspinous space, respectively. All studies reported an increase in motor response measured by recording surface electromyography, voluntary movement, muscle strength, or function. Conclusions. Although this review highlights tSCS as a feasible therapeutic neuromodulatory strategy to enhance voluntary movement, muscle strength, and function in patients with chronic spinal cord injury, the clinical impact and efficacy of electrode location and current intensity need to be characterized in statistically powered and controlled clinical trials.
Percutaneous electrical nerve stimulation (PENS) consists of applying an electric current of <1,000 Hz to different neuromuscular structures through acupuncture needles. Currently, there is ...controversy surrounding the effect of PENS on muscle strength in the scientific literature. The main objective was to assess the effect of PENS applied to the median and cubital nerves on the maximum handgrip strength (MHS) compared to sham stimulation, as well as to determine the safety of the intervention. A parallel, randomized, double‐blind controlled trial in a sample of 20 healthy subjects. Participants were randomly allocated in the experimental (n = 10) and control (n = 10) groups. A blinded researcher measured MHS. Measurements of MHS of the dominant hand were taken at four time points: preintervention, immediately postintervention, 24 hr after the intervention, and at a 10‐day follow‐up. A 10‐Hz percutaneous electrical current stimulation was employed. The control group also received the same puncture method but with no electric stimulation. Compared to baseline, the MHS decreased 10.4% (SEM = 3.2, p = .02) in the PENS group at 24 hr postintervention, with no differences observed between baseline and at 10 days postintervention. No changes in grip strength were observed at any time point in the sham group. To sum up, PENS decreased MHS at 24 hr postintervention, which does not persist 10 days after the stimulation. PENS can be considered a safe technique. Trials with larger sample sizes are required to corroborate the findings of this study. Clinical Trials Registration: NCT, NCT04662229, filed on March 12th of 2020.
Motor impairments are very common in neurological diseases such as multiple sclerosis. Noninvasive brain stimulation could influence the motor function of patients.
The aim of this meta-analysis was ...to evaluate the effectiveness of transcranial direct current stimulation (tDCS) on balance and gait ability in patients with multiple sclerosis. Additionally, a secondary aim was to compare the influence of the stimulation location of tDCS on current effectiveness.
A search was conducted for randomized controlled trials published up to May 2023 comparing the application of tDCS versus a sham or control group. The primary outcome variables were balance and gait ability.
Eleven studies were included in the qualitative analysis, and ten were included in the quantitative analysis, which included 230 patients with multiple sclerosis. The average effect of tDCS on gait functionality was superior to that of the control group (SMD = -0.71; 95% CI, -1.05 to -0.37). However, the overall results of the tDCS vs. sham effect on static balance did not show significant differences between groups (MD = 1.26, 95% CI, -1.31 to 3.82). No significant differences were found when different locations of tDCS were compared.
These results reveal that tDCS is an effective treatment for improving gait ability with a low quality of evidence. However, the application of tDCS has no effect on static balance in patients with multiple sclerosis with very low quality of evidence. Similarly, there seems to be no difference regarding the stimulation area with tDCS.
Transcranial direct current stimulation (tDCS) is a non-invasive brain stimulation method able to modulate neuronal activity after stroke. The aim of this systematic review was to determine if tDCS ...combined with robotic therapy (RT) improves limb function after stroke when compared to RT alone.
A search for randomized controlled trials (RCTs) published prior to July 15, 2021 was performed. The main outcome was function assessed with the Fugl-Meyer motor assessment for upper extremities (FM/ue) and 10-m walking test (10MWT) for the lower limbs. As secondary outcomes, strength was assessed with the Motricity Index (MI) or Medical Research Council scale (MRC), spasticity with the modified Ashworth scale (MAS), functional independence with the Barthel Index (BI), and kinematic parameters.
Ten studies were included for analysis (n = 368 enrolled participants). The results showed a non-significant effect for tDCS combined with RT to improve upper limb function standardized mean difference (SMD) = - 0.12; 95% confidence interval (CI): - 0.35-0.11). However, a positive effect of the combined therapy was observed in the lower limb function (SMD = 0.48; 95% CI: - 0.15-1.12). Significant results favouring tDCS combined with RT were not found in strength (SMD = - 0.15; 95% CI: - 0.4-0.1), spasticity mean difference (MD) = - 0.15; 95% CI: - 0.8-0.5), functional independence (MD = 2.5; 95% CI: - 1.9-6.9) or velocity of movement (SMD = 0.06; 95% CI: - 0.3-0.5) with a "moderate" or "low" recommendation level according to the GRADE guidelines.
Current findings suggest that tDCS combined with RT does not improve upper limb function, strength, spasticity, functional independence or velocity of movement after stroke. However, tDCS may enhance the effects of RT alone for lower limb function. tDCS parameters and the stage or type of stroke injury could be crucial factors that determine the effectiveness of this therapy.
Objective
The objective of this study is to compare the effectiveness of complex physical therapy combined with intermittent pneumatic compression (CPT + IPC) versus Kinesio taping (KT) for breast ...cancer‐related lymphedema.
Methods
A cross‐over clinical trial was conducted in 43 women with lymphedema. All participants received two interventions: CPT + IPC and KT, both lasting 3 weeks and a washout period. The main outcome variable was the relative volume change (RVC). The secondary variables were Satisfaction Questionnaire about Textile Therapeutic Devices used for Breast Cancer‐Related Lymphedema, Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire, motion range of upper limb and lymphedema‐related symptoms.
Results
The RVC reduction was greater with CPT + IPC (−2.2%, SD = 4.7) versus KT (−0.9%, SD = 1.7) (P = 0.002). KT was more satisfactory than multilayer bandaging (8.9 points difference, P < 0.001) and improved DASH score more than CPT + IPC (14.3 points difference, P = 0.002). Regarding motion ranges, only shoulder movements showed significant improvement with CPT + IPC compared with KT (differences between 5.6° and 11.4°). Of the symptoms assessed, only pain reduction showed a significant improvement with KT versus CPT + IPC (0.5 points, P = 0.035).
Conclusions
CPT + IPC achieved higher RVC and greater improvement in th shoulder motion range than KT. Conversely, KT was more satisfactory than multilayer bandaging, obtained better DASH scores and relieved pain more than CPT + IPC.
Clinical Registration
ClinicalTrial registration number: NCT03051750 (date of registration 14 February 2017).
Transcranial direct-current stimulation (tDCS) is an easy-to-apply, cheap, and safe technique capable of affecting cortical brain activity. However, its effectiveness has not been proven for many ...clinical applications.
The aim of this systematic review was to determine whether the effect of different strategies for gait training in patients with neurological disorders can be enhanced by the combined application of tDCS compared to sham stimulation. Additionally, we attempted to record and analyze tDCS parameters to optimize its efficacy.
A search in Pubmed, PEDro, and Cochrane databases was performed to find randomized clinical trials that combined tDCS with gait training. A chronological filter from 2010 to 2018 was applied and only studies with variables that quantified the gait function were included.
A total of 274 studies were found, of which 25 met the inclusion criteria. Of them, 17 were rejected based on exclusion criteria. Finally, 8 trials were evaluated that included 91 subjects with stroke, 57 suffering from Parkinson's disease, and 39 with spinal cord injury. Four of the eight assessed studies did not report improved outcomes for any of its variables compared to the placebo treatment.
There are no conclusive results that confirm that tDCS can enhance the effect of the different strategies for gait training. Further research for specific pathologies, with larger sample sizes and adequate follow-up periods, are required to optimize the existing protocols for applying tDCS.
Unmodulated high-frequency alternating currents (HFAC) are employed for producing peripheral nerves block. HFAC have been applied in humans with frequencies up to 20 kHz, whether transcutaneously, ...percutaneously, or
surgically-implanted electrodes. The aim of this study was to assess the effect of percutaneous HFAC, applied with ultrasound-guided needles at 30 kHz, on the sensory-motor nerve conduction of healthy volunteers.
A parallel, double-blind, randomized clinical trial with a placebo control was conducted. Percutaneous HFAC at 30 kHz or sham stimulation was applied
ultrasound-guided needles in 48 healthy volunteers (
= 24 in each group) for 20 min. The assessed outcome variables were pressure pain threshold (PPT), mechanical detection threshold (MDT), maximal finger flexion strength (MFFS), antidromic sensory nerve action potential (SNAP), hand temperature, and subjective sensations by the participants. The measurements were recorded pre-intervention, during the stimulation (at 15 min), immediately post-intervention (at 20 min), and 15 min after the end of treatment.
The PPT increased in the active group compared with sham stimulation, both during the intervention 14.7%; 95% confidence interval (CI): 4.4-25.0, immediately post-intervention (16.9%; 95% CI: -7.2-26.5), and 15 min after the end of the stimulation (14.3%; 95% CI: 4.4-24.3) (
< 0.01). The proportion of participants who reported feelings of numbness and heaviness was significantly higher in the active group (46 and 50%, respectively) than in the sham group (8 and 18%, respectively) (
< 0.05). No intergroup differences were observed in the remaining outcome variables. No unexpected adverse effects derived from the electrical stimulation were reported.
Percutaneous stimulation with HFAC at 30 kHz applied to the median nerve increased the PPT and subjective perception of numbness and heaviness. Future research should evaluate its potential therapeutic effect in people with pain.
https://clinicaltrials.gov/ct2/show/NCT04884932, identifier NCT04884932.
High frequency alternating current (HFAC) stimulation have been shown to produce a peripheral nerve conduction block. Currently, all the studies applying HFAC stimulation in clinical studies, have ...employed frequencies below 10 kHz. The main aim of this work was to investigate the neuromodulatory effect of transcutaneous 20 kHz stimulation on somatosensory and pain thresholds, and maximal handgrip strength.
A randomized, crossover, single-blinded, placebo-controlled trial was conducted following recruitment of fourteen healthy volunteers. Transcutaneous stimulation at 20 kHz and sham stimulation were applied over the ulnar and median nerves of fourteen healthy volunteers for 20 min. Maximal handgrip strength (MHS), mechanical detection threshold (MDT) and pressure pain threshold (PPT) were registered prior to, during (15 min), immediately after the end (20 min), and 10 min following stimulation.
The 20 kHz stimulation showed a lower MHS during the stimulation at the 15 min (30.1 kgs SE 2.8) and at 20 min (31.8 kgs, SE 2.8) when compared to sham stimulation (35.1 kgs, SE 3.4; p < 0.001 and 34.2 kgs, SE 3.4; p = 0.03, respectively). The 20 kHz stimulation resulted in a slight increase in MDT at 15 min (0.25 mN; 0.25-2.00) when compared to the sham stimulation (0.25 mN; 0.25-0.25; p = 0.02), and no effects were showed for PPT.
High-frequency stimulation at 20 kHz suggests a partial block of nerve activity. Studies in subjects with neurological disorders characterized by nerve hyperactivity are needed to confirm the clinical impact of this non-invasive electrical stimulation technique.
NCT, NCT02837458. Registered on 12 April 2017.
High-frequency alternating currents of greater than 1 kHz applied on peripheral nerves has been used in animal studies to produce a motor nerve block. It has been evidenced that frequencies higher ...than 5 kHz are necessary to produce a complete peripheral nerve block in primates, whose nerve thickness is more similar to humans. The aim of the study was to determine the effect on muscle strength after the application of a high-frequency stimulation at 5 and 10 kHz compared to sham stimulation in healthy volunteers.
Transcutaneous stimulation at 5 kHz, 10 kHz and sham stimulation were applied to eleven healthy volunteers over the ulnar and median nerves for 20 min. Maximal handgrip strength was measured before, during, immediately after the intervention, and 10 min after the end of intervention. The 10 kHz stimulation showed a lower handgrip strength during the intervention (28.1 N, SEM 3.9) when compared to 5 kHz (31.1 N, SEM 3.6; p < 0.001) and to sham stimulation (33.7 N, SEM 3.9; p < 0.001). Furthermore, only stimulation at 10 kHz decreased handgrip strength when compared to baseline.
These findings suggest high-frequency stimulation has an inhibitory effect over muscle strength. Future studies are required in patients that are characterized by motor hyperactive such as spasticity or tremors.
NCT, NCT03169049 . Registered on 30 May 2017.