Background Lateral offset center of rotation (COR) reduces the incidence of scapular notching and potentially increases external rotation range of motion (ROM) after reverse total shoulder ...arthroplasty (rTSA). The purpose of this study was to determine the biomechanical effects of changing COR on abduction and external rotation ROM, deltoid abduction force, and joint stability. Materials and methods A biomechanical shoulder simulator tested cadaveric shoulders before and after rTSA. Spacers shifted the COR laterally from baseline rTSA by 5, 10, and 15 mm. Outcome measures of resting abduction and external rotation ROM, and abduction and dislocation (lateral and anterior) forces were recorded. Results Resting abduction increased 20° vs native shoulders and was unaffected by COR lateralization. External rotation decreased after rTSA and was unaffected by COR lateralization. The deltoid force required for abduction significantly decreased 25% from native to baseline rTSA. COR lateralization progressively eliminated this mechanical advantage. Lateral dislocation required significantly less force than anterior dislocation after rTSA, and both dislocation forces increased with lateralization of the COR. Conclusion COR lateralization had no influence on ROM (adduction or external rotation) but significantly increased abduction and dislocation forces. This suggests the lower incidence of scapular notching may not be related to the amount of adduction deficit after lateral offset rTSA but may arise from limited impingement of the humeral component on the lateral scapula due to a change in joint geometry. Lateralization provides the benefit of increased joint stability, but at the cost of increasing deltoid abduction forces.
Percutaneous osseointegrated (OI) devices for amputees are metallic endoprostheses, that are surgically implanted into the residual stump bone and protrude through the skin, allowing attachment of an ...exoprosthetic limb. In contrast to standard socket suspension systems, these percutaneous OI devices provide superior attachment platforms for artificial limbs. However, bone adaptation, which includes atrophy and/or hypertrophy along the extent of the host bone-endoprosthetic interface, is seen clinically and depends upon where along the bone the device ultimately transfers loading forces to the skeletal system. The goal of this study was to determine if a percutaneous OI device, designed with a porous coated distal region and an end-loading collar, could promote and maintain stable bone attachment. A total of eight, 18 to 24-month old, mixed-breed sheep were surgically implanted with a percutaneous OI device. For 24-months, the animals were allowed to bear weight as tolerated and were monitored for signs of bone remodelling. At necropsy, the endoprosthesis and the surrounding tissues were harvested, radiographically imaged, and histomorphometrically analyzed to determine the periprosthetic bone adaptation in five animals. Bone growth into the porous coating was achieved in all five animals. Serial radiographic data showed stress-shielding related bone adaptation occurs based on the placement of the endoprosthetic stem. When collar placement and achieved end-bearing against the transected bone, distal bone conservation/hypertrophy was observed. The results supported the use of a distally loading and distally porous coated percutaneous OI device to achieve distal host bone maintenance.
Polyacrylate glue protein analogs of the glue secreted by Phragmatopoma californica, a marine polycheate, were synthesized with phosphate, primary amine, and catechol sidechains with molar ratios ...similar to the natural glue proteins. Aqueous mixtures of the mimetic polyelectrolytes condensed into liquid complex coacervates around neutral pH. Wet cortical bone specimens bonded with the coacervates, oxidatively crosslinked through catechol sidechains, had bond strengths nearly 40% of the strength of a commercial cyanoacrylate. The unique material properties of complex coacervates may be ideal for development of clinically useful adhesives and other biomaterials.
A natural marine adhesive was mimicked with synthetic polyelectrolytes to create a water‐borne adhesive for bonding wet cortical bone substrates. Aqueous mixtures of the polyelectrolytes condensed into liquid complex coacervates with ideal properties for an injectable medical adhesive: low interfacial tension, low viscosity, and high solids. The coacervated adhesive cured through oxidative crosslinking of dihydroxyphenol and primary amine sidechains.
Transhumeral percutaneous osseointegrated prostheses provide upper-extremity amputees with increased range of motion, more natural movement patterns, and enhanced proprioception. However, direct ...skeletal attachment of the endoprosthesis elevates the risk of bone fracture, which could necessitate revision surgery or result in loss of the residual limb. Bone fracture loads are direction dependent, strain rate dependent, and load rate dependent. Furthermore, in vivo, bone experiences multiaxial loading. Yet, mechanical characterization of the bone-implant interface is still performed with simple uni- or bi-axial loading scenarios that do not replicate the dynamic multiaxial loading environment inherent in human motion. The objective of this investigation was to reproduce the dynamic multiaxial loading conditions that the humerus experiences in vivo by robotically replicating humeral kinematics of advanced activities of daily living typical of an active amputee population. Specifically, 115 jumping jack, 105 jogging, 15 jug lift, and 15 internal rotation trials-previously recorded via skin-marker motion capture-were replicated on an industrial robot and the resulting humeral trajectories were verified using an optical tracking system. To achieve this goal, a computational pipeline that accepts a motion capture trajectory as input and outputs a motion program for an industrial robot was implemented, validated, and made accessible via public code repositories. The industrial manipulator utilized in this study was able to robotically replicate over 95% of the aforementioned trials to within the characteristic error present in skin-marker derived motion capture datasets. This investigation demonstrates the ability to robotically replicate human motion that recapitulates the inertial forces and moments of high-speed, multiaxial activities for biomechanical and orthopaedic investigations. It also establishes a library of robotically replicated motions that can be utilized in future studies to characterize the interaction of prosthetic devices with the skeletal system, and introduces a computational pipeline for expanding this motion library.
Percutaneous osseointegrated (OI) implants are increasingly viable as an alternative to socket suspension of prosthetic limbs. Upper extremity prostheses have also become more complex to better ...replicate hand and arm function and attempt to recreate pre-amputation functional levels. With more functionality comes heavier devices that put more stress on the bone-implant interface, which could be an issue for implant stability. This study quantified transhumeral loading at defined amputation levels using four simulated prosthetic limb-types: (1) body powered hook, (2) myoelectric hook, (3) myoelectric hand, and (4) advanced prosthetic limb. Computational models were constructed to replicate the weight distribution of each prosthesis type, then applied to motion capture data collected during Advanced Activities of Daily Living (AADLs). For activities that did not include a handheld weight, the body powered prosthesis bending moments were 13-33% (range of means for each activity across amputation levels) of the intact arm moments (reference 100%), torsional moments were 12-15%, and axial pullout forces were 30-40% of the intact case (pless than or equal to0.001). The myoelectric hook and hand bending moments were 60-99%, torsional moments were 44-97%, and axial pullout forces were 62-101% of the intact case. The advanced prosthesis bending moments were 177-201%, torsional moments were 164-326%, and axial pullout forces were 133-185% of the intact case (pless than or equal to0.001). The addition of a handheld weight for briefcase carry and jug lift activities reduced the overall impact of the prosthetic model itself, where the body powered forces and moments were much closer to those of the intact model, and more complex prostheses further increased forces and moments beyond the intact arm levels. These results reveal a ranked order in loading magnitude according to complexity of the prosthetic device, and highlight the importance of considering the patient's desired terminal device when planning post-operative percutaneous OI rehabilitation and training.
Percutaneous osseointegrated (OI) prostheses directly connect an artificial limb to the residual appendicular skeleton via a permanently implanted endoprosthesis with a bridging connector that ...protrudes through the skin. The resulting stoma produces unique medical and biological challenges. Previously, a study using a large animal amputation model indicated that infection could be largely prevented, for at least a 12-month period, but the terminal epithelium continued to downgrow. The current study was undertaken to test the longer-term efficacy of this implant construct to maintain a stable skin-implant interface for 24 months. Using the previously successful amputation and implantation surgical procedure, a total of eight sheep were fitted with a percutaneous OI prosthesis. Two animals were removed from the study due to early complications. Of the remaining six sheep, one (16.7%) became infected at 15-months post-implantation and five remained infection-free for the intended 24 months. The histological data of the remaining animals further confirmed the grossly observable epithelial downgrowth. Albeit a receding interface, it was clear that all animals that survived to the end of the study had residual fibrous soft-tissue ingrowth into, and debris within, the exposed titanium porous-coated surface. Overall, the data demonstrated that the porous coated subdermal barrier offered initial protection against infection. However, the fibrous skin attachment was continuously lysed over time by the down-growing epithelium.
Percutaneous devices are prone to epidermal downgrowth and sinus tract formation, which can serve as a nidus for bacterial colonization and increase the risk of peri-prosthetic infection. A laser ...microgrooved topography has been shown to limit gingival epidermal downgrowth around dental implants. However, the efficacy of this laser microgrooved topography to limit epidermal downgrowth around nongingival percutaneous devices is yet to be investigated. In this study, devices with a porous-coated subdermal component and a percutaneous post were designed and manufactured. The proximal 2 mm section of the percutaneous post were left smooth, or were textured with either a porous coating, or with the laser microgrooved topography. The smooth and porous topographies served as controls. The devices were tested in a hairless guinea pig back model, where 18 animals were randomly assigned into three groups, with each group receiving one implant type (n = 6/group). Four weeks postimplantation, the devices with surrounding soft-tissues were harvested and processed for histological analyses. Results indicated that the laser microgrooved topography failed to prevent epidermal downgrowth (23 ± 4%) around percutaneous posts in this model. Furthermore, no significant differences (p = 0.70) in epidermal downgrowth were present between the three topographies, with all the groups exhibiting similar measures of downgrowth. Overall, these findings suggest that the laser microgrooved topography may not halt downgrowth around percutaneous devices for dermal applications.
Percutaneous osseointegrated (OI) implants for direct skeletal attachment of upper extremity prosthetics represent an alternative to traditional socket suspension that may yield improved patient ...function and satisfaction. This is especially true in high-level, transhumeral amputees where prosthetic fitting is challenging and abandonment rates remain high. However, maintaining mechanical integrity of the bone-implant interface is crucial for safe clinical introduction of this technology. The collection of population data on the transhumeral loading environment will aid in the design of compliance and overload protection devices that mitigate the risk of periprosthetic fracture. We collected marker-based upper extremity kinematic data from non-amputee volunteers during advanced activities of daily living (AADLs) that applied dynamic loading to the humerus. Inverse dynamic analysis was applied to calculate the axial force, bending and torsional moments at three virtual amputation levels representing 25, 50, and 75% residual humeral length. The influences of amputation level, elbow flexion constraint, gender and anthropometric scaling were assessed. Results indicate that the proximal (25%) amputation level experienced significantly higher axial forces and bending moments across all subjects when compared to distal amputation levels (p≤0.030). Constraining elbow flexion had a limited influence on peak transhumeral loads. Male subjects experienced higher axial forces during all evaluated activities (p≤0.023). Peak axial force for all activities occurred during jumping jacks (174.5N). Peak bending (57.6Nm) and torsional (57.2Nm) moments occurred during jumping jacks and rapid internal humeral rotation, respectively. Calculated loads fall within the range of implant fixation failure loads reported in cadaveric investigations of humeral stem fixation; indicating that periprosthetic fracture may occur during non-contact AADLs. These kinematic data, collected over a range of AADLs, will aid in the development of overload protection devices and appropriate post-operative rehabilitation protocols that balance return to an active lifestyle with patient safety.
Cortical trajectory screw constructs, developed as an alternative to pedicle screw fixation for the lumbar spine, have similar in vitro biomechanics. The possibility of one screw path having the ...ability to rescue the other in a revision scenario holds promise but has not been evaluated. The objective in this study was to investigate the biomechanical properties of traditional pedicle screws and cortical trajectory screws when each was used to rescue the other in the setting of revision.
Ten fresh-frozen human lumbar spines were instrumented at L3-4, 5 with cortical trajectory screws and 5 with pedicle screws. Construct stiffness was recorded in flexion/extension, lateral bending, and axial rotation. The L-3 screw pullout strength was tested to failure for each specimen and salvaged with screws of the opposite trajectory. Mechanical stiffness was again recorded. The hybrid rescue trajectory screws at L-3 were then tested to failure.
Cortical screws, when used in a rescue construct, provided stiffness in flexion/extension and axial rotation similar to that provided by the initial pedicle screw construct prior to failure. The rescue pedicle screws provided stiffness similar to that provided by the primary cortical screw construct in flexion/extension, lateral bending, and axial rotation. In pullout testing, cortical rescue screws retained 60% of the original pedicle screw pullout strength, whereas pedicle rescue screws retained 65% of the original cortical screw pullout strength.
Cortical trajectory screws, previously studied as a primary mode of fixation, may also be used as a rescue option in the setting of a failed or compromised pedicle screw construct in the lumbar spine. Likewise, a standard pedicle screw construct may rescue a compromised cortical screw track. Cortical and pedicle screws each retain adequate construct stiffness and pullout strength when used for revision at the same level.