Organs-on-chips at the frontiers of drug discovery Esch, Eric W; Bahinski, Anthony; Huh, Dongeun
Nature reviews. Drug discover/Nature reviews. Drug discovery,
04/2015, Letnik:
14, Številka:
4
Journal Article
Recenzirano
Odprti dostop
Improving the effectiveness of preclinical predictions of human drug responses is critical to reducing costly failures in clinical trials. Recent advances in cell biology, microfabrication and ...microfluidics have enabled the development of microengineered models of the functional units of human organs - known as organs-on-chips - that could provide the basis for preclinical assays with greater predictive power. Here, we examine the new opportunities for the application of organ-on-chip technologies in a range of areas in preclinical drug discovery, such as target identification and validation, target-based screening, and phenotypic screening. We also discuss emerging drug discovery opportunities enabled by organs-on-chips, as well as important challenges in realizing the full potential of this technology.
Analysis of enterovirus infection is difficult in animals because they express different virus receptors than humans, and static cell culture systems do not reproduce the physical complexity of the ...human intestinal epithelium. Here, using coxsackievirus B1 (CVB1) as a prototype enterovirus strain, we demonstrate that human enterovirus infection, replication and infectious virus production can be analyzed in vitro in a human Gut-on-a-Chip microfluidic device that supports culture of highly differentiated human villus intestinal epithelium under conditions of fluid flow and peristalsis-like motions. When CVB1 was introduced into the epithelium-lined intestinal lumen of the device, virions entered the epithelium, replicated inside the cells producing detectable cytopathic effects (CPEs), and both infectious virions and inflammatory cytokines were released in a polarized manner from the cell apex, as they could be detected in the effluent from the epithelial microchannel. When the virus was introduced via a basal route of infection (by inoculating virus into fluid flowing through a parallel lower 'vascular' channel separated from the epithelial channel by a porous membrane), significantly lower viral titers, decreased CPEs, and delayed caspase-3 activation were observed; however, cytokines continued to be secreted apically. The presence of continuous fluid flow through the epithelial lumen also resulted in production of a gradient of CPEs consistent with the flow direction. Thus, the human Gut-on-a-Chip may provide a suitable in vitro model for enteric virus infection and for investigating mechanisms of enterovirus pathogenesis.
Smoking represents a major risk factor for chronic obstructive pulmonary disease (COPD), but it is difficult to characterize smoke-induced injury responses under physiological breathing conditions in ...humans due to patient-to-patient variability. Here, we show that a small airway-on-a-chip device lined by living human bronchiolar epithelium from normal or COPD patients can be connected to an instrument that “breathes” whole cigarette smoke in and out of the chips to study smoke-induced pathophysiology in vitro. This technology enables true matched comparisons of biological responses by culturing cells from the same individual with or without smoke exposure. These studies led to identification of ciliary micropathologies, COPD-specific molecular signatures, and epithelial responses to smoke generated by electronic cigarettes. The smoking airway-on-a-chip represents a tool to study normal and disease-specific responses of the human lung to inhaled smoke across molecular, cellular and tissue-level responses in an organ-relevant context.
Display omitted
•Smoking lung airway chip recapitulated clinical oxidative stress molecular profiles•New smoke-induced ciliary micropathologies were identified•This technology supported study of potential toxic effects of electronic cigarettes•COPD-specific responses were reproduced in vitro and novel biomarkers were identified
Benam et al. describe a microengineered in vitro model system that permits analysis of the effects of whole smoke, from both conventional tobacco and electronic cigarettes, delivered under physiologically relevant flow conditions that mimic breathing on the pathophysiology of differentiated human mucociliated bronchiolar epithelium cultured in a microfluidic small airway-on-a-chip.
Abstract
Animal models are 78% accurate in determining whether drugs will alter contractility of the human heart. To evaluate the suitability of human-induced pluripotent stem cell-derived ...cardiomyocytes (hiPSC-CMs) for predictive safety pharmacology, we quantified changes in contractility, voltage, and/or Ca2+ handling in 2D monolayers or 3D engineered heart tissues (EHTs). Protocols were unified via a drug training set, allowing subsequent blinded multicenter evaluation of drugs with known positive, negative, or neutral inotropic effects. Accuracy ranged from 44% to 85% across the platform-cell configurations, indicating the need to refine test conditions. This was achieved by adopting approaches to reduce signal-to-noise ratio, reduce spontaneous beat rate to ≤ 1 Hz or enable chronic testing, improving accuracy to 85% for monolayers and 93% for EHTs. Contraction amplitude was a good predictor of negative inotropes across all the platform-cell configurations and of positive inotropes in the 3D EHTs. Although contraction- and relaxation-time provided confirmatory readouts forpositive inotropes in 3D EHTs, these parameters typically served as the primary source of predictivity in 2D. The reliance of these “secondary” parameters to inotropy in the 2D systems was not automatically intuitive and may be a quirk of hiPSC-CMs, hence require adaptations in interpreting the data from this model system. Of the platform-cell configurations, responses in EHTs aligned most closely to the free therapeutic plasma concentration. This study adds to the notion that hiPSC-CMs could add value to drug safety evaluation.
Abstract
Cardiovascular toxicity is an important cause of drug failures in the later stages of drug development, early clinical safety assessment, and even postmarket withdrawals. Early-stage in ...vitro assessment of potential cardiovascular liabilities in the pharmaceutical industry involves assessment of interactions with cardiac ion channels, as well as induced pluripotent stem cell-derived cardiomyocyte-based functional assays, such as calcium flux and multielectrode-array assays. These methods are appropriate for the identification of acute functional cardiotoxicity but structural cardiotoxicity, which manifests effects after chronic exposure, is often only captured in vivo. CardioMotion is a novel, label-free, high throughput, in vitro assay and analysis pipeline which records and assesses the spontaneous beating of cardiomyocytes and identifies compounds which impact beating. This is achieved through the acquisition of brightfield images at a high framerate, combined with an optical flow-based python analysis pipeline which transforms the images into waveform data which are then parameterized. Validation of this assay with a large dataset showed that cardioactive compounds with diverse known direct functional and structural mechanisms-of-action on cardiomyocytes are identified (sensitivity = 72.9%), importantly, known structural cardiotoxins also disrupt cardiomyocyte beating (sensitivity = 86%) in this method. Furthermore, the CardioMotion method presents a high specificity of 82.5%.
Polydimethylsiloxane (PDMS) has numerous desirable properties for fabricating microfluidic devices, including optical transparency, flexibility, biocompatibility, and fabrication by casting; however, ...partitioning of small hydrophobic molecules into the bulk of PDMS hinders industrial acceptance of PDMS microfluidic devices for chemical processing and drug development applications. Here we describe an attractive alternative material that is similar to PDMS in terms of optical transparency, flexibility and castability, but that is also resistant to absorption of small hydrophobic molecules.
Lamotrigine, approved for use as an antiseizure medication as well as the treatment of bipolar disorder, inhibits sodium channels in the brain to reduce repetitive neuronal firing and pathological ...release of glutamate. The shared homology of sodium channels and lack of selectivity associated with channel blocking agents can cause slowing of cardiac conduction and increased proarrhythmic potential. The Vaughan‐Williams classification system differentiates sodium channel blockers using biophysical properties of binding. As such, Class Ib inhibitors, including mexiletine, do not slow cardiac conduction as measured by the electrocardiogram, at therapeutically relevant exposure. Our goal was to characterize the biophysical properties of NaV1.5 block and to support the observed clinical safety of lamotrigine. We used HEK‐293 cells stably expressing the hNaV1.5 channel and voltage clamp electrophysiology to quantify the potency (half‐maximal inhibitory concentration) against peak and late channel current, on‐/off‐rate binding kinetics, voltage‐dependence, and tonic block of the cardiac sodium channel by lamotrigine; and compared to clinically relevant Class Ia (quinidine), Ib (mexiletine), and Ic (flecainide) inhibitors. Lamotrigine blocked peak and late NaV1.5 current at therapeutically relevant exposure, with rapid kinetics and biophysical properties similar to the class Ib inhibitor mexiletine. However, no clinically meaningful prolongation in QRS or PR interval was observed in healthy subjects in a new analysis of a previously reported thorough QT clinical trial (SCA104648). In conclusion, the weak NaV1.5 block and rapid kinetics do not translate into clinically relevant conduction slowing at therapeutic exposure and support the clinical safety of lamotrigine in patients suffering from epilepsy and bipolar disorder.
We have derived a cardiac muscle cell line, designated HL-1, from the AT-1 mouse atrial cardiomyocyte tumor lineage. HL-1 cells can be serially passaged, yet they maintain the ability to contract and ...retain differentiated cardiac morphological, biochemical, and electrophysiological properties. Ultrastructural characteristics typical of embryonic atrial cardiac muscle cells were found consistently in the cultured HL-1 cells. Reverse transcriptase-PCR-based analyses confirmed a pattern of gene expression similar to that of adult atrial myocytes, including expression of α -cardiac myosin heavy chain, α -cardiac actin, and connexin43. They also express the gene for atrial natriuretic factor. Immunohistochemical staining of the HL-1 cells indicated that the distribution of the cardiac-specific markers desmin, sarcomeric myosin, and atrial natriuretic factor was similar to that of cultured atrial cardiomyocytes. A delayed rectifier potassium current (IKr) was the most prominent outward current in HL-1 cells. The activating currents displayed inward rectification and deactivating current tails were voltage-dependent, saturated at γ +20 mV, and were highly sensitive to dofetilide (IC50of 46.9 nM). Specific binding of 3Hdofetilide was saturable and fit a one-site binding isotherm with a Kdof 140 +/- 60 nM and a Bmaxof 118 fmol per 105cells. HL-1 cells represent a cardiac myocyte cell line that can be repeatedly passaged and yet maintain a cardiac-specific phenotype.
Previous studies demonstrated increased fatty acid uptake and metabolism in MHC-FATP transgenic mice that overexpress fatty acid transport protein (FATP)1 in the heart under the control of the ...alpha-myosin heavy chain (alpha-MHC) promoter. Doppler tissue imaging and hemodynamic measurements revealed diastolic dysfunction, in the absence of changes in systolic function. The experiments here directly test the hypothesis that the diastolic dysfunction in MHC-FATP mice reflects impaired ventricular myocyte contractile function. In vitro imaging of isolated adult MHC-FATP ventricular myocytes revealed that mean diastolic sarcomere length is significantly (P<0.01) shorter than in wild-type (WT) cells (1.79+/-0.01 versus 1.84+/-0.01 microm). In addition, the relaxation rate (dL/dt) is significantly (P<0.05) slower in MHC-FATP than WT myocytes (1.58+/-0.09 versus 1.92+/-0.13 microm/s), whereas both fractional shortening and contraction rates are not different. Application of 40 mmol/L 2,3-butadionemonoxime (a nonspecific ATPase inhibitor that relaxes actin-myosin interactions) increased diastolic sarcomere length in both WT and MHC-FATP myocytes to the same length, suggesting that MHC-FATP myocytes are partially activated at rest. Direct measurements of intracellular Ca(2+) revealed that diastolic Ca(2+)(i) is unchanged in MHC-FATP myocytes and the rate of calcium removal is unexpectedly faster in MHC-FATP than WT myocytes. Moreover, diastolic sarcomere length in MHC-FATP and WT myocytes was unaffected by removal of extracellular Ca(2+) or by buffering of intracellular Ca(2+) with the Ca(2+) chelator BAPTA (100 micromol/L), indicating that elevated intracellular Ca(2+) does not underlie impaired diastolic function in MHC-FATP ventricular myocytes. Functional assessment of skinned myocytes, however, revealed that myofilament Ca(2+) sensitivity is markedly increased in MHC-FATP, compared with WT, ventricular cells. In addition, biochemical experiments demonstrated increased expression of the beta-MHC isoform in MHC-FATP, compared with WT ventricles, which likely contributes to the slower relaxation rate observed in MHC-FATP myocytes. Collectively, these data demonstrate that derangements in lipid metabolism in MHC-FATP ventricles, which are similar to those observed in the diabetic heart, result in impaired diastolic function that primarily reflects changes in myofilament function, rather than altered Ca(2+) cycling.
'Organs-on-chips' are microengineered biomimetic systems containing microfluidic channels lined by living human cells, which replicate key functional units of living organs to reconstitute integrated ...human organ-level pathophysiology in vitro. These microdevices can be used to test efficacy and toxicity of drugs and chemicals, and to create in vitro models of human disease. Thus, they potentially represent low-cost alternatives to conventional animal models for pharmaceutical, chemical and environmental applications. Here we describe a protocol for the fabrication, microengineering and operation of these microfluidic organ-on-chip systems. First, microengineering is used to fabricate a multilayered microfluidic device that contains two parallel elastomeric microchannels separated by a thin porous flexible membrane, along with two full-height, hollow vacuum chambers on either side; this requires ∼3.5 d to complete. To create a 'breathing' lung-on-a-chip that mimics the mechanically active alveolar-capillary interface of the living human lung, human alveolar epithelial cells and microvascular endothelial cells are cultured in the microdevice with physiological flow and cyclic suction applied to the side chambers to reproduce rhythmic breathing movements. We describe how this protocol can be easily adapted to develop other human organ chips, such as a gut-on-a-chip lined by human intestinal epithelial cells that experiences peristalsis-like motions and trickling fluid flow. Also, we discuss experimental techniques that can be used to analyze the cells in these organ-on-chip devices.