Photoelectric X-ray Polarimetry with Gas Pixel Detectors Bellazzini, Ronaldo; Brez, Alessandro; Costa, Enrico ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
08/2013, Letnik:
720
Journal Article
Recenzirano
The Gas Pixel Detector, recently developed and continuously improved by Pisa-INFN in collaboration with IASF-Roma (INAF), can visualize the tracks produced within a low Z gas by photoelectrons of few ...keV. By reconstructing the impact point and the original direction of the photoelectrons, the GPD can measure the polarization plane of X-Ray photons, while preserving the information on the absorption point, the energy and the time of arrival of individual photons. Applied to X-ray Astrophysics, in the focus of grazing incidence telescopes, it can perform angular and energy resolved polarimetry with a large improvement of sensitivity, when compared with the conventional techniques of Bragg diffraction at 45° and Compton scattering around 90°. This configuration has been the basis of POLARIX and HXMT, two pathfinder missions, and was included in the baseline design of IXO, the very large X-ray telescope under study by NASA, ESA and JAXA. We have recently improved the design of this low energy polarimeter (2–10keV) by modifying the geometry of the absorption cell to minimize any systematic effect that could leave a residual polarization signal for non-polarized source. We will report on the testing of this new concept.
PolarLight is a compact soft X-ray polarimeter onboard a CubeSat, which was launched into a low-Earth orbit on October 29, 2018. In March 2019, PolarLight started full operation, and since then, ...regular observations with the Crab nebula, Sco X-1, and background regions have been conducted. Here we report the operation, calibration, and performance of PolarLight in the orbit. Based on these, we discuss how one can run a low-cost, shared CubeSat for space astronomy, and how CubeSats can play a role in modern space astronomy for technical demonstration, science observations, and student training.
Purpose:
High-resolution, photon-counting, energy-resolved detector with fast-framing capability can facilitate simultaneous acquisition of precontrast and postcontrast images for subtraction ...angiography without pixel registration artifacts and can facilitate high-resolution real-time imaging during image-guided interventions. Hence, this study was conducted to determine the spatial resolution characteristics of a hexagonal pixel array photon-counting cadmium telluride (CdTe) detector.
Methods:
A 650 μm thick CdTe Schottky photon-counting detector capable of concurrently acquiring up to two energy-windowed images was operated in a single energy-window mode to include photons of 10 keV or higher. The detector had hexagonal pixels with apothem of 30 μm resulting in pixel pitch of 60 and 51.96 μm along the two orthogonal directions. The detector was characterized at IEC-RQA5 spectral conditions. Linear response of the detector was determined over the air kerma rate relevant to image-guided interventional procedures ranging from 1.3 nGy/frame to 91.4 μGy/frame. Presampled modulation transfer was determined using a tungsten edge test device. The edge-spread function and the finely sampled line spread function accounted for hexagonal sampling, from which the presampled modulation transfer function (MTF) was determined. Since detectors with hexagonal pixels require resampling to square pixels for distortion-free display, the optimal square pixel size was determined by minimizing the root-mean-squared-error of the aperture functions for the square and hexagonal pixels up to the Nyquist limit.
Results:
At Nyquist frequencies of 8.33 and 9.62 cycles/mm along the apothem and orthogonal to the apothem directions, the modulation factors were 0.397 and 0.228, respectively. For the corresponding axis, the limiting resolution defined as 10% MTF occurred at 13.3 and 12 cycles/mm, respectively. Evaluation of the aperture functions yielded an optimal square pixel size of 54 μm. After resampling to 54 μm square pixels using trilinear interpolation, the presampled MTF at Nyquist frequency of 9.26 cycles/mm was 0.29 and 0.24 along the orthogonal directions and the limiting resolution (10% MTF) occurred at approximately 12 cycles/mm. Visual analysis of a bar pattern image showed the ability to resolve close to 12 line-pairs/mm and qualitative evaluation of a neurovascular nitinol-stent showed the ability to visualize its struts at clinically relevant conditions.
Conclusions:
Hexagonal pixel array photon-counting CdTe detector provides high spatial resolution in single-photon counting mode. After resampling to optimal square pixel size for distortion-free display, the spatial resolution is preserved. The dual-energy capabilities of the detector could allow for artifact-free subtraction angiography and basis material decomposition. The proposed high-resolution photon-counting detector with energy-resolving capability can be of importance for several image-guided interventional procedures as well as for pediatric applications.
With the specialization of VLSI ASICs for front-end signal processing electronics, the customization of the control back-end electronics (BEE) has become critical to fully deploy the ASIC ...performance. In the context of space operations, with typical constraints on power and reliability, the design and qualification of such integrated systems present significant challenges. In this paper, we review the design and performance of the BEE systems after two years of operations in low Earth orbit (LEO); these systems read out the custom ASICs inside the gas pixel detectors, which are located at the heart of the imaging X-ray polarimetry explorer (IXPE), a NASA-ASI small explorer mission designed to measure X-ray polarization in the 2–8 keV energy range.
The Sun is the nearest astrophysical source with a very intense emission in the X-ray band. The study of energetic events, such as solar flares, can help us to understand the behaviour of the ...magnetic field of our star. There are in the literature numerous studies published about polarization predictions, for a wide range of solar flares models involving the emission from thermal and/or non-thermal processes, but observations in the X-ray band have never been exhaustive.
The gas pixel detector (GPD) was designed to achieve X-ray polarimetric measurements as well as X-ray images for far astrophysical sources. Here we present the possibility to employ this instrument for the observation of our Sun in the X-ray band.
Due to the advent of a new generation of detectors, X-ray polarimetry promises to join X-ray imaging, spectroscopy and timing as one of the main observational techniques in high energy astrophysics. ...This has renewed interest in the field, and indeed several polarimetric missions have recently been proposed. This volume provides a complete and up-to-date view of the subject for researchers in astrophysics. The contributors discuss the present status and perspectives of instruments, review current theoretical models, and examine future missions. As well as detailed papers, the book contains broad reviews that can be easily understood by astrophysicists new to the field.