The OLYMPUS Collaboration reports on a precision measurement of the positron-proton to electron-proton elastic cross section ratio, R_{2γ}, a direct measure of the contribution of hard two-photon ...exchange to the elastic cross section. In the OLYMPUS measurement, 2.01 GeV electron and positron beams were directed through a hydrogen gas target internal to the DORIS storage ring at DESY. A toroidal magnetic spectrometer instrumented with drift chambers and time-of-flight scintillators detected elastically scattered leptons in coincidence with recoiling protons over a scattering angle range of ≈20° to 80°. The relative luminosity between the two beam species was monitored using tracking telescopes of interleaved gas electron multiplier and multiwire proportional chamber detectors at 12°, as well as symmetric Møller or Bhabha calorimeters at 1.29°. A total integrated luminosity of 4.5 fb^{-1} was collected. In the extraction of R_{2γ}, radiative effects were taken into account using a Monte Carlo generator to simulate the convolutions of internal bremsstrahlung with experiment-specific conditions such as detector acceptance and reconstruction efficiency. The resulting values of R_{2γ}, presented here for a wide range of virtual photon polarization 0.456<ε<0.978, are smaller than some hadronic two-photon exchange calculations predict, but are in reasonable agreement with a subtracted dispersion model and a phenomenological fit to the form factor data.
A design for a compact x-ray light source (CXLS) with flux and brilliance orders of magnitude beyond existing laboratory scale sources is presented. The source is based on inverse Compton scattering ...of a high brightness electron bunch on a picosecond laser pulse. The accelerator is a novel high-efficiency standing-wave linac and rf photoinjector powered by a single ultrastable rf transmitter at X-band rf frequency. The high efficiency permits operation at repetition rates up to 1 kHz, which is further boosted to 100 kHz by operating with trains of 100 bunches of 100 pC charge, each separated by 5 ns. The entire accelerator is approximately 1 meter long and produces hard x rays tunable over a wide range of photon energies. The colliding laser is a Yb∶YAG solid-state amplifier producing 1030 nm, 100 mJ pulses at the same 1 kHz repetition rate as the accelerator. The laser pulse is frequency-doubled and stored for many passes in a ringdown cavity to match the linac pulse structure. At a photon energy of 12.4 keV, the predicted x-ray flux is 5×1011photons/second in a 5% bandwidth and the brilliance is 2×1012photons/(secmm2mrad20.1%) in pulses with rms pulse length of 490 fs. The nominal electron beam parameters are 18 MeV kinetic energy, 10 microamp average current, 0.5 microsecond macropulse length, resulting in average electron beam power of 180 W. Optimization of the x-ray output is presented along with design of the accelerator, laser, and x-ray optic components that are specific to the particular characteristics of the Compton scattered x-ray pulses.
We report the first measurement of the average of the electron-proton and positron-proton elastic scattering cross sections. This lepton charge-averaged cross section is insensitive to the leading ...effects of hard two-photon exchange, giving more robust access to the proton's electromagnetic form factors. The cross section was extracted from data taken by the OLYMPUS experiment at DESY, in which alternating stored electron and positron beams were scattered from a windowless gaseous hydrogen target. Elastic scattering events were identified from the coincident detection of the scattered lepton and recoil proton in a large-acceptance toroidal spectrometer. The luminosity was determined from the rates of Møller, Bhabha, and elastic scattering in forward electromagnetic calorimeters. The data provide some selectivity between existing form factor global fits and will provide valuable constraints to future fits.
The GlueX experiment at Jefferson Laboratory aims to perform quantitative tests of non-perturbative QCD by studying the spectrum of light-quark mesons and baryons. A Detector of Internally Reflected ...Cherenkov light (DIRC) was installed to enhance the particle identification (PID) capability of the GlueX experiment by providing clean
π
/K separation up to 3.7 GeV/
c
momentum in the forward region (
θ
< 11°), which will allow the study of hybrid mesons decaying into kaon final states with significantly higher efficiency and purity. The new PID system is constructed with radiators from the decommissioned BaBar DIRC counter, combined with new compact photon cameras based on the SuperB FDIRC concept. The full system was successfully installed and commissioned with beam during 2019/2020. The initial PID performance of the system was evaluated and compared to one from Geant4 simulation.
Abstract
The search for a dark photon holds considerable interest in the physics community. Such a force carrier would begin to illuminate the dark sector. Many experiments have searched for such a ...particle, but so far it has proven elusive. In recent years the concept of a low mass dark photon has gained popularity in the physics community. Of particular recent interest is the
8
Be and
4
He anomaly, which could be explained by a new fifth force carrier with a mass of 17 MeV/
c
2
. The proposed Darklight experiment would search for this potential low mass force carrier at ARIEL in the 10-20 MeV/
c
2
e
+
e
−
invariant mass range. This proceeding will focus on the experimental design and physics case of the Darklight experiment.
The OLYMPUS experiment Milner, R.; Hasell, D.K.; Kohl, M. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
03/2014, Letnik:
741
Journal Article
Recenzirano
Odprti dostop
The OLYMPUS experiment was designed to measure the ratio between the positron–proton and electron–proton elastic scattering cross-sections, with the goal of determining the contribution of two-photon ...exchange to the elastic cross-section. Two-photon exchange might resolve the discrepancy between measurements of the proton form factor ratio, μpGEp/GMp, made using polarization techniques and those made in unpolarized experiments. OLYMPUS operated on the DORIS storage ring at DESY, alternating between 2.01GeV electron and positron beams incident on an internal hydrogen gas target. The experiment used a toroidal magnetic spectrometer instrumented with drift chambers and time-of-flight detectors to measure rates for elastic scattering over the polar angular range of approximately 25°–75°. Symmetric Møller/Bhabha calorimeters at 1.29° and telescopes of GEM and MWPC detectors at 12° served as luminosity monitors. A total luminosity of approximately 4.5fb−1 was collected over two running periods in 2012. This paper provides details on the accelerator, target, detectors, and operation of the experiment.