Two polarization-independent Michelson fiber interferometers with different optical delays were used to measure the in-band OSNR of an optical signal from 5 to 30 dB within an accuracy of 0.5 dB. ...Using an expansion of the amplitude autocorrelation function of the signal around zero delay, it was possible to perform measurements without any prior knowledge of the signal. The system is shown to be immune to the effects of modulation frequency (up to 10G), partially and fully polarized noise, chromatic dispersion and poorly biased modulators.
Carbon tetrachloride (CCl4) is an ozone-depleting substance, which is controlled by the Montreal Protocol and for which the atmospheric abundance is decreasing. However, the current observed rate of ...this decrease is known to be slower than expected based on reported CCl4 emissions and its estimated overall atmospheric lifetime. Here we use a three-dimensional (3-D) chemical transport model to investigate the impact on its predicted decay of uncertainties in the rates at which CCl4 is removed from the atmosphere by photolysis, by ocean uptake and by degradation in soils. The largest sink is atmospheric photolysis (74 % of total), but a reported 10 % uncertainty in its combined photolysis cross section and quantum yield has only a modest impact on the modelled rate of CCl4 decay. This is partly due to the limiting effect of the rate of transport of CCl4 from the main tropospheric reservoir to the stratosphere, where photolytic loss occurs. The model suggests large interannual variability in the magnitude of this stratospheric photolysis sink caused by variations in transport. The impact of uncertainty in the minor soil sink (9 % of total) is also relatively small. In contrast, the model shows that uncertainty in ocean loss (17 % of total) has the largest impact on modelled CCl4 decay due to its sizeable contribution to CCl4 loss and large lifetime uncertainty range (147 to 241 years). With an assumed CCl4 emission rate of 39 Gg year−1, the reference simulation with the best estimate of loss processes still underestimates the observed CCl4 (overestimates the decay) over the past 2 decades but to a smaller extent than previous studies. Changes to the rate of CCl4 loss processes, in line with known uncertainties, could bring the model into agreement with in situ surface and remote-sensing measurements, as could an increase in emissions to around 47 Gg year−1. Further progress in constraining the CCl4 budget is partly limited by systematic biases between observational datasets. For example, surface observations from the National Oceanic and Atmospheric Administration (NOAA) network are larger than from the Advanced Global Atmospheric Gases Experiment (AGAGE) network but have shown a steeper decreasing trend over the past 2 decades. These differences imply a difference in emissions which is significant relative to uncertainties in the magnitudes of the CCl4 sinks.
Incident human immunodeficiency virus (HIV) infections among adolescent females and women declined during 2010-2016, with the largest decrease (21%) occurring among black women (1). However, in 2016, ...although black women accounted for 13% of the U.S. female population, 60% of new HIV infections among women were in black women, indicating persisting disparities (1). CDC used the population attributable proportion (PAP) disparity measure to describe the proportional decrease in HIV infection among black and white women combined that would be realized if the group with the higher rate (blacks) had the same rate as did the group with the lower rate (whites) (2). Analyses indicated that an estimated 3,900 of 4,200 (93%) incident HIV infections among black women in 2016 would not have occurred if rates were the same for black and white women. The PAP disparity measure decreased from 0.75 in 2010 to 0.70 in 2016, suggesting that if incidence rates for black women were the same as those for white women, the annual number of incident HIV infections among black and white women would have been 75% lower in 2010 and 70% lower in 2016. Continued efforts are needed to identify and address social and structural determinants associated with HIV-related disparities to eliminate these disparities and decrease HIV incidence among black women.
Previous studies have suggested that the incidence of retinopathy is lower in preterm infants with exposure to reduced levels of oxygenation than in those exposed to higher levels of oxygenation. ...However, it is unclear what range of oxygen saturation is appropriate to minimize retinopathy without increasing adverse outcomes.
We performed a randomized trial with a 2-by-2 factorial design to compare target ranges of oxygen saturation of 85 to 89% or 91 to 95% among 1316 infants who were born between 24 weeks 0 days and 27 weeks 6 days of gestation. The primary outcome was a composite of severe retinopathy of prematurity (defined as the presence of threshold retinopathy, the need for surgical ophthalmologic intervention, or the use of bevacizumab), death before discharge from the hospital, or both. All infants were also randomly assigned to continuous positive airway pressure or intubation and surfactant.
The rates of severe retinopathy or death did not differ significantly between the lower-oxygen-saturation group and the higher-oxygen-saturation group (28.3% and 32.1%, respectively; relative risk with lower oxygen saturation, 0.90; 95% confidence interval CI, 0.76 to 1.06; P=0.21). Death before discharge occurred more frequently in the lower-oxygen-saturation group (in 19.9% of infants vs. 16.2%; relative risk, 1.27; 95% CI, 1.01 to 1.60; P=0.04), whereas severe retinopathy among survivors occurred less often in this group (8.6% vs. 17.9%; relative risk, 0.52; 95% CI, 0.37 to 0.73; P<0.001). There were no significant differences in the rates of other adverse events.
A lower target range of oxygenation (85 to 89%), as compared with a higher range (91 to 95%), did not significantly decrease the composite outcome of severe retinopathy or death, but it resulted in an increase in mortality and a substantial decrease in severe retinopathy among survivors. The increase in mortality is a major concern, since a lower target range of oxygen saturation is increasingly being advocated to prevent retinopathy of prematurity. (ClinicalTrials.gov number, NCT00233324.)
Expression of B7-H1, a costimulating glycoprotein in the B7 family, is normally restricted to macrophage-lineage cells, providing a potential costimulatory signal source for regulation of T cell ...activation. In contrast, aberrant expression of B7-H1 by tumor cells has been implicated in impairment of T cell function and survival, resulting in defective host antitumoral immunity. The relationship between tumor-associated B7-H1 and clinical cancer progression is unknown. Herein, we report B7-H1 expression by both renal cell carcinoma (RCC) tumors of the kidney and RCC tumor-infiltrating lymphocytes. In addition, our analysis of 196 clinical specimens reveals that patients harboring high intratumoral expression levels of B7-H1, contributed by tumor cells alone, lymphocytes alone, or tumor and/or lymphocytes combined, exhibit aggressive tumors and are at markedly increased risk of death from RCC. In fact, patients with high tumor and/or lymphocyte B7-H1 levels are 4.5 times more likely to die from their cancer than patients exhibiting low levels of B7-H1 expression (risk ratio 4.53; 95% confidence interval 1.94-10.56; P < 0.001.) Thus, our study suggests a previously undescribed mechanism whereby RCC may impair host immunity to foster tumor progression. B7-H1 may prove useful as a prognostic variable for RCC patients both pre- and posttreatment. In addition, B7-H1 may represent a promising target to facilitate more favorable responses in patients who require immunotherapy for treatment of advanced RCC.
In this letter, a novel method of chromatic dispersion monitoring via two-photon absorption (TPA) is investigated. A specially designed semiconductor microcavity is employed as a TPA detector for ...monitoring data signals operating at rates up to 80Gb/s. As the microcavity has a wavelength-dependent response, a single device can be used to monitor multiple channels in a multiwavelength optical telecommunication system
Some sexually experienced African American females abstain from sexual activity for various reasons and periods of time following sexual debut (secondary abstinence), reducing their risk of ...HIV/sexually transmitted infection (STI) acquisition. However, few studies have sought to understand secondary abstinence motivations. Furthermore, the scope of existing knowledge may be limited by the quantitative approaches employed. Thus, the purpose of this qualitative study was to investigate secondary abstinence motivations among African American females using a grounded theory approach. Interviews were conducted with 20 young women, aged 18 to 23 years, who recently completed a sexual risk–reduction intervention. Motivations for secondary abstinence not identified in previous studies included feeling used for sex, partner infidelity, and abuse or sexual assault. Also, young women were motivated to abstain to focus on improving certain aspects of their lives. Other motivations similar to those previously identified included not being married or in a committed relationship, separation from one’s partner, and STI and pregnancy experiences or fears. Insight from this investigation can be used to improve measurement of motivations and to develop and refine HIV/STI interventions for this population.
This paper presents a theoretical and experimental investigation into the use of a two-photon absorption (TPA) photodetector for use in chromatic dispersion (CD) monitoring in high-speed, WDM ...network. In order to overcome the inefficiency associated with the nonlinear optical-to-electrical TPA process, a microcavity structure is employed. An interesting feature of such a solution is the fact that the microcavity enhances only a narrow wavelength range determined by device design and angle at which the signal enters the device. Thus, a single device can be used to monitor a number of different wavelength channels without the need for additional external filters. When using a nonlinear photodetector, the photocurrent generated for Gaussian pulses is inversely related to the pulsewidth. However, when using a microcavity structure, the cavity bandwidth also needs to be considered, as does the shape of the optical pulses incident on the device. Simulation results are presented for a variety of cavity bandwidths, pulse shapes and durations, and spacing between adjacent wavelength channels. These results are verified experimental using a microcavity with a bandwidth of 260 GHz (2.1 nm) at normal incident angle, with the incident signal comprising of two wavelength channels separated by 1.25 THz (10 nm), each operating at an aggregate data rate of 160 Gb/s. The results demonstrate the applicability of the presented technique to monitor accumulated dispersion fluctuations in a range of 3 ps/nm for 160 Gb/s RZ data channel.