Objectives The purpose of this study was to examine the incremental value of copeptin for rapid rule out of acute myocardial infarction (AMI). Background The rapid and reliable exclusion of AMI is a ...major unmet clinical need. Copeptin, the C-terminal part of the vasopressin prohormone, as a marker of acute endogenous stress may be useful in this setting. Methods In 487 consecutive patients presenting to the emergency department with symptoms suggestive of AMI, we measured levels of copeptin at presentation, using a novel sandwich immunoluminometric assay in a blinded fashion. The final diagnosis was adjudicated by 2 independent cardiologists using all available data. Results The adjudicated final diagnosis was AMI in 81 patients (17%). Copeptin levels were significantly higher in AMI patients compared with those in patients having other diagnoses (median 20.8 pmol/l vs. 6.0 pmol/l, p < 0.001). The combination of troponin T and copeptin at initial presentation resulted in an area under the receiver-operating characteristic curve of 0.97 (95% confidence interval: 0.95 to 0.98), which was significantly higher than the 0.86 (95% confidence interval: 0.80 to 0.92) for troponin T alone (p < 0.001). A copeptin level <14 pmol/l in combination with a troponin T ≤0.01 μg/l correctly ruled out AMI with a sensitivity of 98.8% and a negative predictive value of 99.7%. Conclusions The additional use of copeptin seems to allow a rapid and reliable rule out of AMI already at presentation and may thereby obviate the need for prolonged monitoring and serial blood sampling in the majority of patients. (Advantageous Predictors of Acute Coronary Syndromes Evaluation APACE; NCT00470587 )
To examine the diagnostic accuracy of sensitive cardiac troponin (cTn) assays in elderly patients, since elevated levels with sensitive cTn assays were reported in 20% of elderly patients without ...acute myocardial infarction (AMI).
In this multi-centre study, we included 1098 consecutive patients presenting with symptoms suggestive of AMI, 406 (37%) were >70 years old. Measurement of three investigational sensitive cTn assays Roche high-sensitive cTnT (hs-cTnT), Siemens cTnI-Ultra, and Abbott-Architect cTnI) and the standard assay (Roche cTnT) was performed in a blinded fashion. The final diagnosis was adjudicated by two independent cardiologists. Acute myocardial infarction was the adjudicated final diagnosis in 24% of elderly patients. Among elderly patients without AMI, baseline cTn levels were elevated above the 99th percentile in 51% with Roche hs-cTnT, in 17% with Siemens TnI-Ultra, and 13% with Abbott-Architect cTnI. The diagnostic accuracy as quantified by the area under the receiver operating characteristic (ROC) curve (AUC) was significantly greater for the sensitive cTn assays compared with the standard assay (AUC for Roche hs-cTnT, 0.94; Siemens cTnI-Ultra, 0.95; and Abbott-Architect cTnI, 0.95 vs. AUC for the standard assay, 0.90; P < 0.05 for comparisons). The best cut-offs for the sensitive cTn-assays determined by the ROC-curve in elderly patients differed clearly from those in younger patients. Furthermore, the prognostic value regarding 90-day mortality varied among the sensitive cTn assays.
Sensitive cTn assays have high diagnostic accuracy also in the elderly. Mild elevations are common in elderly non-AMI patients, therefore the optimal cut-off levels are substantially higher in elderly as compared with younger patients. Furthermore, sensitive cTn assays yielded different prognostic value.
Clinical performance of the novel high-sensitivity cardiac troponin I (Siemens-hs-cTnI-Centaur) assay is unknown. We aimed to clinically validate the Siemens-hs-cTnI-Centaur assay and develop 0/1-h ...and 0/2-h algorithms.
We enrolled patients presenting to the emergency department with symptoms suggestive of acute myocardial infarction (AMI). Final diagnoses were centrally adjudicated by 2 independent cardiologists including all clinical information twice: first, using serial hs-cTnT (Roche-Elecsys, primary analysis); second, using hs-cTnI (Abbott-Architect, secondary analysis) measurements in addition to the clinically applied (hs)-cTn. Siemens-hs-cTnI-Centaur was measured at presentation, 1 h, and 2 h. The primary objective was a direct comparison of diagnostic accuracy, quantified by the area under the ROC curve (AUC), of Siemens-hs-cTnI-Centaur vs the 2 established hs-cTn assays (Roche-hs-cTnT-Elecsys, Abbott-hs-cTnI-Architect). Secondary objectives included the development of Siemens-hs-cTnI-Centaur-specific 0/1-h and 0/2-h algorithms.
AMI was the final diagnosis in 318 of 1755 (18%) patients (using Roche-hs-cTnT-Elecsys for adjudication). The AUC at presentation for Siemens-hs-cTnI-Centaur was 0.94 (95% CI, 0.92-0.96) and comparable with 0.95 (95% CI, 0.93-0.97) for Roche-hs-cTnT-Elecsys and 0.93 (95% CI, 0.90-0.96) for Abbott-hs-cTnI-Architect. Applying the derived Siemens-hs-cTnI-Centaur 0/1-h algorithm to the validation cohort, 46% of patients were ruled out (sensitivity, 99.1%; 95% CI, 95.3-100), and 18% of patients were ruled in (specificity, 94.1%; 95% CI, 91.8-95.9). The Siemens-hs-cTnI-Centaur 0/2-h algorithm ruled out 55% of patients (sensitivity, 100%; 95% CI, 94.1-100), and ruled in 18% of patients (specificity, 96.0%; 95% CI, 93.1-97.9). Findings were confirmed in the secondary analyses using serial measurements of Abbott-hs-cTnI-Architect for adjudication.
Diagnostic accuracy and clinical utility of the novel Siemens-hs-cTnI-Centaur assay are high and comparable with the established hs-cTn assays. ClinicalTrials.gov Identifier: NCT00470587.
Abstract Objectives The aim of this study was to perform a meta-analysis of currently available data regarding the prognostic significance of soluble suppression of tumorigenecity–2 (sST2) ...concentration in acute heart failure (AHF). Background Concentration of sST2 may have prognostic value in AHF. A comprehensive assessment of all available studies regarding sST2 in AHF is lacking. Methods Three databases (MEDLINE, Cochrane Library, and Scopus) were searched. Inclusion criteria were follow-up studies, papers published in English, enrollment of patients with AHF, and availability of median hazard ratios for all-cause death and other outcome measures, when available. Results Ten studies were included, with a global population of 4,835 patients and a median follow-up duration of 13.5 months. The following global hazard ratios calculated for log2 (sST2) were admission sST2 and all-cause death, 2.46 (95% confidence interval CI: 1.80 to 3.37; p < 0.001); discharge sST2 and all-cause death, 2.06 (95% CI: 1.37 to 3.11; p < 0.001); admission sST2 and cardiovascular death, 2.29 (95% CI: 1.41 to 3.73; p < 0.001); discharge sST2 and cardiovascular death, 2.20 (95% CI: 1.48 to 3.25; p < 0.001); admission sST2 and heart failure (HF) hospitalization, 1.21 (95% CI: 0.96 to 1.52; p = 0.060); discharge sST2 and HF hospitalization, 1.54 (95% CI: 1.03 to 2.32; p = 0.007); admission sST2 and all-cause death or HF hospitalization, 1.74 (95% CI: 1.24 to 2.45; p < 0.001); and discharge sST2 and all-cause death or HF hospitalization, 1.63 (95% CI: 1.14 to 2.33; p < 0.001). Conclusions Plasma sST2 has prognostic value with respect to all-cause and cardiovascular death as well as the composite outcome of all-cause death or HF hospitalization, with both admission and discharge values having prognostic efficacy. Discharge sST2, but not admission sST2, is predictive of HF rehospitalization during follow-up.
The non-ST-segment-elevation myocardial infarction (NSTEMI) guidelines of the European Society of Cardiology (ESC) recommend a 3h cardiac troponin determination in patients triaged to the ...observe-zone of the ESC 0/1h-algorithm; however, no specific cutoff for further triage is endorsed. Recently, a specific cutoff for 0/3h high-sensitivity cardiac troponin T (hs-cTnT) change (7 ng/L) was proposed, warranting external validation.
Patients presenting with acute chest discomfort to the emergency department were prospectively enrolled into an international multicenter diagnostic study. Final diagnoses were centrally adjudicated by 2 independent cardiologists applying the fourth universal definition of myocardial infarction, on the basis of complete cardiac workup, cardiac imaging, and serial hs-cTnT. Hs-cTnT concentrations were measured at presentation, after 1 hour, and after 3 hours. The objective was to externally validate the proposed cutoff, and if necessary, derive and internally as well as externally validate novel 0/3h-criteria for the observe-zone of the ESC 0/1h-hs-cTnT-algorithm in an independent multicenter cohort.
Among 2076 eligible patients, application of the ESC 0/1h-hs-cTnT-algorithm triaged 1512 patients (72.8%) to either rule out or rule in NSTEMI, leaving 564 patients (27.2%) in the observe-zone (adjudicated NSTEMI prevalence, 120/564 patients, 21.3%). The suggested 0/3h-hs-cTnT-change of <7 ng/L triaged 517 patients (91.7%) toward rule-out, resulting in a sensitivity of 33.3% (95% CI, 25.5-42.2), missing 80 patients with NSTEMI, and ≥7 ng/L triaged 47 patients toward rule-in (8.3%), resulting in a specificity of 98.4% (95% CI, 96.8-99.2). Novel derived 0/3h-criteria for the observe-zone patients ruled out NSTEMI with a 3h hs-cTnT concentration <15 ng/L and a 0/3h-hs-cTnT absolute change <4 ng/L, triaging 138 patients (25%) toward rule-out, resulting in a sensitivity of 99.2% (95% CI, 96.0-99.9), missing 1 patient with NSTEMI. A 0/3h-hs-cTnT absolute change ≥6 ng/L triaged 63 patients (11.2%) toward rule-in, resulting in a specificity of 98% (95% CI, 96.2-98.9) Thereby, the novel 0/3h-criteria reduced the number of patients in the observe zone by 36%s and the number of type 1 myocardial infarction by 50%. Findings were confirmed in both internal and external validation.
A combination of a 3h-hs-cTnT concentration (<15 ng/L) and a 0/3h absolute change (<4 ng/L) is necessary to safely rule out NSTEMI in patients remaining in the observe-zone of the ESC 0/1h-hs-cTnT-algorithm. Registration: URL: https://clinicaltrials.gov; Unique identifier: NCT00470587.
The clinical utility of procalcitonin in the diagnosis and management of pneumonia remains controversial.
We assessed the clinical utility of procalcitonin in 2 prospective studies: first, a ...multicenter diagnostic study in patients presenting to the emergency department with acute dyspnea to directly compare the diagnostic accuracy of procalcitonin with that of interleukin 6 and C-reactive protein (CRP) in the diagnosis of pneumonia; second, a randomized management study of procalcitonin guidance in patients with acute heart failure and suspected pneumonia. Diagnostic accuracy for pneumonia as centrally adjudicated by 2 independent experts was quantified with the area under the ROC curve (AUC).
Among 690 patients in the diagnostic study, 178 (25.8%) had an adjudicated final diagnosis of pneumonia. Procalcitonin, interleukin 6, and CRP were significantly higher in patients with pneumonia than in those without. When compared to procalcitonin (AUC = 0.75; 95% CI, 0.71-0.78), interleukin 6 (AUC = 0.80; 95% CI, 0.77-0.83) and CRP (AUC = 0.82; 95% CI, 0.79-0.85) had significantly higher diagnostic accuracy (
= 0.010 and
< 0.001, respectively). The management study was stopped early owing to the unexpectedly low AUC of procalcitonin in the diagnostic study. Among 45 randomized patients, the number of days on antibiotic therapy and the length of hospital stay were similar (both
= 0.39) in patients randomized to the procalcitonin-guided group (n = 25) and usual-care group (n = 20).
In patients presenting with dyspnea, diagnostic accuracy of procalcitonin for pneumonia is only moderate and lower than that of interleukin 6 and CRP. The clinical utility of procalcitonin was lower than expected.
Pneumonia has diverse and often unspecific symptoms. As the role of biomarkers in the diagnosis of pneumonia remains controversial, it is often difficult to distinguish pneumonia from other illnesses causing shortness of breath. The current study prospectively enrolled unselected patients presenting with acute dyspnea and directly compared the diagnostic accuracy of procalcitonin, interleukin 6, and CRP for the diagnosis of pneumonia. In this setting, diagnostic accuracy of procalcitonin for pneumonia was lower as compared to interleukin 6 and CRP. The clinical utility of procalcitonin was lower than expected.
NCT01831115.
Abstract Background Biomarkers may help to monitor and tailor treatment in patients with acute heart failure (AHF). Methods and Results Levels of ST2, a novel biomarker integrating hypervolemic ...cardiac strain and proinflammatory signals, were measured at presentation to the emergency department (ED) and after 48 hours in 207 patients with AHF. Patients were stratified according to their early ST2 response (responders: ST2 decrease ≥25%; nonresponders: ST2 decrease <25%) and beta-blocker, renin-angiotensin-aldosterone system (RAAS) blockade, or diuretic treatment status at hospital discharge. We assessed the utility of ST2 levels and its changes to predict long-term mortality and the interaction between ST2 levels, treatment at discharge, and 1-year mortality. ST2 levels were higher in nonsurvivors than in survivors (median 108 vs 69 ng/mL; P < .01) and decreased significantly during the 1st 48 hours (median decrease 33%). ST2 decrease was less in nonsurvivors compared with survivors (median −25% vs −42%; P < .01). In Cox regression, early ST2 changes independently predicted 1-year mortality (hazard ratio 1.07 for every increase of 10%; P = .02). RAAS blockers at discharge were associated with survival independently from ST2 response, whereas the association of beta-blockers with survival differed markedly according to ST2 response, with beneficial effects restricted to ST2 nonresponders ( P interaction = .04). A similar, albeit nonsignificant, trend was observed for diuretics ( P interaction = .11). Conclusions ED and serial ST2 measurements are independent predictors of 1-year mortality in AHF.
The 2020 guidelines of the European Society of Cardiology (ESC) recommend a novel ESC 0/2h-algorithm as the preferred alternative to the ESC 0/1h-algorithm in the early triage for rule-out and/or ...rule-in of Non-ST-segment-elevation myocardial infarction (NSTEMI). The aim was to prospectively validate the performance of the ESC 0/2h-algorithm using the high-sensitivity cardiac troponin I (hs-cTnI) assay (ARCHITECT) in an international, multicenter diagnostic study enrolling patients presenting with acute chest discomfort to the emergency department.
Deranged calcium-phosphate metabolism contributes to the burden of morbidity and mortality in dialysis patients. This study aimed to assess the association of the phosphaturic hormone fibroblast ...growth factor 23 (FGF23) and soluble Klotho with all-cause mortality. We measured soluble Klotho and FGF23 levels at enrolment and two weeks later in 239 prevalent hemodialysis patients. The primary hypothesis was that low Klotho and high FGF23 are associated with increased mortality. The association between Klotho and atrial fibrillation (AF) at baseline was explored as secondary outcome. AF was defined as presence of paroxysmal, persistent or permanent AF. During a median follow-up of 924 days, 59 (25%) patients died from any cause. Lower Klotho levels were not associated with mortality in a multivariable adjusted analysis when examined either on a continuous scale (HR 1.25 per SD increase, 95% CI 0.84-1.86) or in tertiles, with tertile 1 as the reference category (HR for tertile two 0.65, 95% CI 0.26-1.64; HR for tertile three 2.18, 95% CI 0.91-2.23). Higher Klotho levels were associated with the absence of AF in a muItivariable logistic regression analysis (OR 0.66 per SD increase, 95% CI 0.41-1.00). Higher FGF23 levels were associated with mortality risk in a multivariable adjusted analysis when examined either on a continuous scale (HR 1.45 per SD increase, 95% CI 1.05-1.99) or in tertiles, with the tertile 1 as the reference category (HR for tertile two 1.63, 95% CI 0.64-4.14; HR for tertile three 3.91, 95% CI 1.28-12.20). FGF23 but not Klotho levels are associated with mortality in hemodialysis patients. Klotho may be protective against AF.