The aim of our study was to evaluate the diagnostic accuracy of B-Mode ultrasound and Hepatorenal Index (HRI) by high-end devices for the detection and classification of hepatic steatosis in patients ...with various causes of chronic liver disease (CLD).
We retrospectively enrolled patients with CLD who underwent liver biopsy and baseline ultrasound between March 2016 and May 2019. Sonographic graduation of steatosis (0°-III°) using B-Mode criteria and HRI were correlated with the histological graduation (S0 (<5% fat), S1 (≥5-33%), S2 (>33-66%) and S3 (>66%). Interobserver agreement was calculated.
157 patients were evaluated. B-Mode ultrasound had a sensitivity of 75.6% and a specificity of 76.0% to differentiate between steatosis and no steatosis (AUROC 0.758). Using B-Mode criteria for advanced steatosis (≥II°), specificity for presence of histological steatosis was ≥98.7%. For detection of advanced steatosis (≥S2), sensitivity of B-mode criteria was 90.9%. In a subgroup of patients with advanced liver fibrosis, sensitivity of B-mode criteria was 95.0% for detection of advanced steatosis (S≥2). A HRI cut-off-value of 1.46 differentiates between patients with steatosis and patients without steatosis with a sensitivity of 42.7% and a specificity of 90.7% (AUROC 0.680). Interobserver agreement of both B-Mode and HRI was good to excellent.
B-Mode ultrasound using high-end devices is an excellent method to detect advanced steatosis in patients with various CLD. For diagnosis of mild steatosis, modern ultrasound devices may have higher sensitivity but at the expense of specificity. Stage of fibrosis and etiology of CLD seem not to impact on diagnostic accuracy. The additional calculation of HRI seems to have no additional benefit with regard to detect or grade hepatic steatosis in our study population.
Background and aims
With an external additional working channel (AWC) endoscopic mucosal resection (EMR) as well as endoscopic submucosal dissection (ESD) can be extended to techniques termed “EMR+” ...and “ESD+.” These novel techniques are systematically compared to EMR and ESD under the use of a double-channel endoscope (DC).
Methods
Our trial was conducted prospectively in a pre-clinical porcine animal model (EASIE-R simulator) with standardized gastric lesions measuring 3 or 4 cm.
Results
EMR+ and EMR DC showed both good results for 3 cm lesions with no adverse events and an en bloc resection rate of 73.33% (EMR+) and 60.00% (EMR DC,
p
= 0.70). They came to their limits in 4 cm lesions with muscularis damages of 20.00% (EMR+), 13.33% (EMR DC,
p
≥ 0.99) and decreasing en bloc resection rates of 60.00% (EMR+) and 46.67% (EMR DC,
p
= 0.72).
ESD+ and ESD DC were both reliable concerning en bloc resection rates (100% in all groups) and adverse events (0.00% in 3 cm lesions, 12.50% muscularis damages in both ESD+ and ESD DC in 4 cm lesions).
Resection time was slightly shorter in all groups with the AWC compared to DC although only reaching significance in 3 cm ESD lesions (
p
< 0.05*).
Conclusions
With the AWC, a standard endoscope can easily be transformed to double-channel functionality. We could show that EMR+ and ESD+ are non-inferior to EMR and ESD under the use of a double-channel endoscope. Consequently, the AWC presents an affordable alternative to a double-channel endoscope for both EMR and ESD.
Background and aims
A new external additional working channel (AWC) was recently introduced by which endoscopic submucosal dissection (ESD) can be converted to a technique termed “ESD+ ”. We aim to ...systematically evaluate this novel technique in flat gastric lesions and compare it to classical ESD.
Methods
The study was prospectively conducted in a pre-clinical ex vivo animal model (EASIE-R simulator) with porcine stomachs. Prior to intervention, we set standardized lesions measuring 3 cm or 4 cm in antegrade as well as in retrograde positions.
Results
Overall, 64 procedures were performed by an experienced endoscopist. Both techniques were reliable and showed en bloc resection rates of 100%. Overall, ESD+ reduced time of procedure compared to ESD (24.5 vs. 32.5 min,
p
= 0.025*). Particularly, ESD+ was significantly faster in retrograde lesions with a median of 22.5 vs. 34.0 min in 3 cm retrograde lesions (
p
= 0.002*) and 34.5 vs. 41.0 min (
p
= 0.011*) in 4 cm retrograde lesions. There were 0 perforations with both techniques. In ESD+ , 1 muscularis damage occurred (3.13%) compared to 6 muscularis damages with ESD (18.75%,
p
= 0.045*).
Conclusions
By its grasp-and-mobilize technique, ESD+ allows potentially faster and safer resections of flat gastric lesions compared to conventional ESD in an ex vivo porcine model. The potential advantages of ESD+ in terms of procedure time may be particularly relevant for difficult lesions in retrograde positions.
Treatment of recurrent malignant ascites in cancer patients is a challenge. Evidence based guidelines regarding the best treatment strategy are lacking. The aim of this prospective study was to ...investigate the safety and efficacy of a tunnelled peritoneal catheter (PleurX) in cancer patients with symptomatic ascites. Patients with symptomatic, diuretics-refractory ascites and indication for the implantation of a tunnelled peritoneal PleurX catheter were prospectively enrolled between August 2018 and July 2020. The number of catheter days, complications, amount of drained ascites and ascites-associated symptoms and hospitalization rate pre- and post-PleurX insertion were analysed. 51 Patients (64.7% male) were prospectively enrolled. The mean age was 66.6 (±7.9) years. The most common cause of ascites was pancreatic adenocarcinoma (n = 10) followed by cholangiocellular carcinoma (n = 9) and hepatocellular carcinoma (n = 8). The technical success rate of PleurX implantation was 100%. The mean volume of weakly drained ascites was 5.44l (±4.08). Major complications included cellulitis (n = 2), peritonitis and drainage dislocation (each n = 1). The mean catheter days per patient was 59.8 (±107.4) (Min 4, Max 668). Abdominal discomfort, impaired mobility, dyspnoea, fatigue, nausea and vomiting were significantly reduced 30 days after PleurX insertion (p < 0.05). Moreover, hospitalization rate was significantly reduced (p < 0.001; 27.08% of days preimplantation vs. 11.27% postimplantation). We conclude that implantation of a tunnelled ascites catheter is a safe and effective method for the treatment of refractory ascites in cancer patients with advanced disease. Serious complications are rare. Burdensome ascites-associated symptoms and hospitalization rates can be significantly reduced over a longer period of time.
In critically ill patients, liver dysfunction often results in coagulopathy and encephalopathy and is associated with high mortality. Extracorporeal clearance of hepatotoxic metabolites, including ...bilirubin and ammonia, aims to attenuate further hepatocyte damage and liver injury, resulting in decreased mortality. The efficacy of hemadsorption combined with conventional hemodialysis to eliminate bilirubin and ammonia to support the liver's excretory function in acute liver injury has been described previously. However, the optimal use of liver support systems in chronic liver dysfunction due to secondary sclerosing cholangitis in critically ill patients (SSC-CIP) has not been defined yet. We herein describe the kinetics of successful bilirubin and ammonia elimination by hemadsorption in a patient with SSC-CIP after extracorporeal membrane oxygenation (ECMO) therapy for severe acute respiratory distress syndrome (ARDS) in a patient with coronavirus disease 2019 (COVID-19). During the course of the disease, the patient developed laboratory signs of liver injury during ECMO therapy before clinically detectable jaundice or elevated bilirubin levels. A diagnosis of SSC-CIP was confirmed by endoscopic retrograde cholangiopancreatography (ERCP) based on intraductal filling defects in the intrahepatic bile ducts due to biliary casts. The patient showed stable elevations of bilirubin and ammonia levels thereafter, but presented with progressive nausea, vomiting, weakness, and exhaustion. Based on these laboratory findings, hemadsorption was combined with hemodialysis treatment and successfully eliminated bilirubin and ammonia. Moreover, direct comparison revealed that ammonia is more efficiently eliminated by hemadsorption than bilirubin levels. Clinical symptoms of nausea, vomiting, weakness, and exhaustion improved. In summary, bilirubin and ammonia were successfully eliminated by hemadsorption combined with hemodialysis treatment in SSC-CIP following ECMO therapy and severe COVID-19. This observation is particularly relevant since it has been reported that a considerable subset of critically ill patients with COVID-19 suffer from liver dysfunction associated with high mortality.
Background/aims: Esophageal varices (EV) are common complications in patients with advanced chronic liver disease (ACLD). Non-invasive parameters to exclude EV in patients with ACLD would be ...desirable. The aim of this study was the evaluation of liver stiffness measurement (LSM) using 2D-shear wave elastography (GE Logiq E9) and other non-invasive parameters as predictors for EV.
Methods: Hundred patients with ACLD were enrolled. Abdominal sonography, including measurement of gall bladder wall thickness (GBWT), spleen diameter and LSM, gastroscopy and blood test results were evaluated. Statistical analyses were performed for the association between EV and non-invasive parameters.
Results: Fifty-one per cent of the patients had EV. The mean LSM (14.6 kPa) and GBWT (3.88 mm) in the group with EV were significantly higher than in the group without EV (10.6 kPa; 2.94 mm; p < .01). Performing area under the receiver operating characteristic curve, LSM has a better diagnostic performance (0.781) than GBWT (0.707), spleen diameter (0.672) and platelet count (0.635). Combining LSM (cut-off 13.58 kPa) and GBWT (cut-off 3.07 mm) resulted in a sensitivity of 86.3% and a specificity of 71.4% for the presence of EV. A sensitivity of 100% (negative predictive value 1.0) was achieved at LSM >9 kPa or GBWT >4 mm. Following these criteria in our current study population, 18% of the gastroscopies could have been avoided.
Conclusions: Combining LSM with non-invasive parameters, especially GBWT, improves the diagnostic accuracy for predicting EV. We suggest reconsidering screening gastroscopy in patients with ACLD who show LSM <9 kPa and GBWT <4 mm due to the very low risk of having varices.
Background and Aims. In contrast to guideline recommendations, endoscopic testing for Helicobacter pylori is frequently performed under Helicobacter pylori suppressive conditions, e.g., intake of ...proton-pump inhibitors (PPI), preceded antibiotic treatment, or recent gastrointestinal bleeding. Our study’s aim was to retest patients with—under suppressive conditions—negative test results. This was carried out in order to examine the rate of false negative tests previously gathered under suppressive conditions. Methods. The trial was conducted in a large patient collective in a university hospital. Every elective esophagogastroduodenoscopy from in- and outpatients was included. Prior to endoscopy, suppressive conditions were collected via standardized questionnaire. If Helicobacter pylori testing was indicated, both helicobacter urease test and histology were performed in analogy to the Sydney classification. In case of a negative result under suppressive conditions, the patient was reinvited after, if possible, withdrawal of suppressive condition in order to perform a urea breath test (UBT). Results. 1,216 patients were included (median 59 years, 72.0% inpatients, 28.0% outpatients). Overall, 60.6% (737) were under Helicobacter pylori suppressive conditions. The main suppressive condition was intake of PPIs (54.5%). In 53.7% (653) of all included cases, Helicobacter pylori testing was performed. Of those, 14.1% (92) had a positive test, and 85.9% (561) were negative. Out of the patients with negative result, 50.8% (285) were tested under suppressive conditions and consequently invited for retesting via UBT. In 20.4% (45), suppressive conditions could not be ceased. In 22.8% (65), retesting was conducted. Of those, 98.5% (64) congruently presented a negative result again, and only 1.5% (1) was positive for Helicobacter pylori. Conclusion. Many patients undergoing esophagogastroduodenoscopy in everyday clinical practice are tested for Helicobacter pylori under suppressive conditions leading to a potentially higher risk of false negative results. However, our research shows that this issue might be overestimated.
Purpose
Increased gallbladder wall thickness (GBWT) is a common finding. Reported causes include advanced chronic liver disease (ACLD), ascites and hypalbuminemia. GBWT is a marker for the prediction ...of esophageal varices. It remains unclear which of these factors is the decisive driver of GBWT. We aim to investigate whether there is a predominant factor associated with the GBWT.
Methods
We enrolled 258 patients with ascites, hypalbuminemia and/or ACLD and 98 healthy volunteers that underwent abdominal ultrasound. Differences of mean GBWT in subgroups of patients with ACLD, ascites, and/or hypalbuminemia were analyzed. Correlation between various parameters and GBWT were calculated using multiple regression analysis.
Results
GBWT in patients with ACLD + ascites + hypalbuminemia (n = 59; 5.70 ± 2.05 mm) was pathologically increased compared to patients with hypalbuminemia + ascites without ACLD (n = 36; 2.14 ± 0.66 mm; p < .001) and to patients with only hypalbuminemia (n = 76; 2.02 ± 0.80 mm; p < .001). GBWT of patients with ACLD + hypalbuminemia (n = 30; 3.42 ± 1.52 mm) and with ACLD and normal albumin level were not different (n = 46; 3.10 ± 1.62 mm; p > .999). Significant correlation was seen between GBWT and ACLD (r = .53; p < .001) and ascites (r = .51; p < .001) but not albumin level (r = .04; p = .510).
Conclusion
We demonstrate that ACLD is predominantly associated with GBWT. In contrast to the current literature, serum albumin level appears not to be associated with pathological GBWT.
Representative image of a gallbladder of a patient with liver cirrhosis and ascites using a convex transducer (4.0 MHz). The gallbladder wall is pathologically thickened
Tumor grading is a robust prognostic predictor in patients with neuroendocrine neoplasms (NEN) and guides therapy, especially in tumors with high proliferation. NEN can be separated into ...well-differentiated and poorly differentiated types. The more aggressive NEN have been further separated into neuroendocrine tumors (NET G3) with a better prognosis and neuroendocrine carcinomas (NEC) with a worse prognosis. Despite this distinction’s tremendous clinical and therapeutic relevance, optimal diagnostic biomarkers are still lacking. In this study, we analyzed the protein expression and prognostic impact of Enhancer of Zeste Homolog 2 (EZH2) by immunohistochemistry in 219 tissue samples of gastroenteropancreatic (GEP-NEN) and pulmonary NEN (P-NEN). EZH2 was almost exclusively expressed in NEN with a proliferation rate above 20% (G3), while all low-grade tumors were nearly negative. Among high-grade NEN, 65% showed high and 35% low expression of EZH2. In this group, the high expression of EZH2 was significantly associated with poor overall survival and NEC histology. Interestingly, EZH2 seems to act independently of Polycomb Repressive Complex 2 (PRC2) in NEN. In conclusion, we propose EZH2 as a robust biomarker for distinguishing between NET G3 and NEC among gastroenteropancreatic and pulmonary NEN.
Background/aims: 2D-shearwave elastography is an established method for liver stiffness measurement (LSM). However, the success rate of LSM using the recommended standard technique in the right lobe ...is limited by several factors. We aimed to compare LSM in the right and left liver lobe in order to evaluate whether LSM in the left lobe could be an alternative if measurements in the right lobe are not feasible.
Methods: A total of 116 subjects, 58 healthy volunteers and 58 patients with chronic liver disease (CLD), were prospectively included. LSM were performed in the right lobe and in the left lobe, both in neutral and in inspiration position.
Results: LSM in the left lobe (8.39(±4.83)kPa) was significantly (p < .001) higher than LSM in the right lobe (6.27(±2.45)kPa). LSM in inspiration position (8.60(±4.33) kPa) was significantly (p = .009) higher than LSM in neutral position (7.70(±3.01)kPa). LSM in the left lobe overestimated the grade of fibrosis in 50.0% of the patients with CLD. However, correlation between LSM values right and left was strong (r = 0.856) and additional use of LSM in the left lobe increased the success rate from 106/116 (91.4%) to 112/116 (96.6%; p = .098). High skin-to-liver-capsule-distance and presence of ascites were independent risk factors for non-successful LSM.
Conclusions: Despite significantly higher values, LSM in the left lobe may be an alternative if LSM in the right lobe is not feasible, and cirrhosis can be ruled out with high probability if LSM is within the normal range.