To develop a risk of bias tool for pre-clinical dental materials research studies that aims to support reporting of future investigations and improve assessment in systematic reviews.
A four-stage ...process following EQUATOR network recommendations was followed, which included project launch, literature review, Delphi process and the tool finalization. With the support of the European Federation of Conservative Dentistry (EFCD) and the Dental Materials Group of the International Association for Dental Research (DMG-IADR), a total of 26 expert stakeholders were included in the development and Delphi vote of the initial proposal. The proposal was built using data gathered from the literature review stage. During this stage, recent systematic reviews featuring dental materials research, and risk of bias tools found in the literature were comprehensively scanned for bias sources. The experts thus reached a consensus for the items, domains and judgement related to the tool, allowing a detailed guide for each item and corresponding signalling questions.
The tool features nine items in total, spread between 4 domains, pertaining to the following types of bias: bias related to planning and allocation (D1), specimen preparation (D2), outcome assessment (D3) and data treatment and outcome reporting (D4). RoBDEMAT, as presented, features signalling questions and a guide that can be used for RoB judgement. Its use as a checklist is preferred over a final summary score.
RoBDEMAT is the first risk of bias tool for pre-clinical dental materials research, supported and developed by a broad group of expert stakeholders in the field, validating its future use.
This new tool will contribute the study field by improving the scientific quality and rigour of dental materials research studies and their systematic reviews. Such studies are the foundation and support of future clinical research and evidence-based decisions.
Various materials and systems for bonding lithium disilicate to the tooth substrate are available to clinicians, who can adapt the materials to each clinical situation to maximize the performance of ...indirect esthetic restorations. This study aimed to evaluate the degree of conversion (DC) and the microhardness (MH) of a dual-curing and a light-curing cement under lithium disilicate discs of different thicknesses.
A total of 48 lithium disilicate (IPS e.max CAD, Ivoclar Vivadent) samples were prepared and divided into three groups (n = 16) according to the thickness (group A was 0.6 mm; group B was 1.0 mm; group C was 1.5 mm). Each group was further divided into two subgroups (n = 8) according to the resin cement employed, NX3 (Kerr) or Choice 2 (Bisco). A standardized quantity of cement was placed on the sample, and DC was evaluated with an attenuated total reflectance Fourier transformed infrared spectrophotometer (Nicolet IS10, Thermo Scientific). Twenty-four hours after DC was established, Vickers test was performed on the cement with a microindentometer (Leica Microsystems). Results were statistically analyzed with analysis of variance test and significance set at P < .05.
Statistical analysis showed cement type had a significant influence (P = .005) on DC. MH results were influenced by thicknesses only between 0.6 and 1.5 mm when light-cured cement was employed.
The light-curing and the dual-curing cements reached comparable DCs between 0.6 and 1.5 mm. However, the light-curing resin showed a higher DC and MH.
The aim of this study was to investigate, by the means of microtensile bond strength (μTBS) test, gelatin and in situ zymography, the influence of 0.2% CHX contained within a commercially available ...adhesive on long-term bond strength and endogenous enzymatic activity.
Non-carious teeth were subjected to μTBS test (N = 15 for each group) and stressed until failure. μTBS was evaluated immediately and after 12-month storage in artificial saliva at 37 °C. Dentin powder was obtained from additional teeth (N = 7) for gelatin zymography, while for in situ zymography, 3 teeth for each group were selected. Gelatin and in situ zymography were performed in dentin powder and slices of dentin, respectively, to assess the ability of 0.2% CHX blended within the adhesive to inhibit endogenous enzymatic activity.
μTBS bond strength was higher in the CHX-containing groups, immediately as well as after aging. The bond strength significantly decreased after 12-month aging. The activation of endogenous MMPs was found to be related to the presence of CHX within the adhesive system and the bonding strategy employed.
Under this perspective 0.2% CHX blended within Peak Universal adhesive monomer seems to increase immediate bond strength, to preserve bond strength over time and to efficiently inhibit endogenous enzymatic activity in dentin. Hence, blending the CHX in low concentrations within the adhesive could be recommended as a feasible technique in every-day clinical practice.
Using CHX-containing adhesives could be recommended due to several benefits: it seems to increase the longevity of the hybrid layer; the inhibitor appears to be efficiently delivered to the dentinal substrate and to inhibit endogenous enzymatic activity, without prolonging chair time.
This study aimed at evaluating the effects of different surface conditionings on the microshear bond strength (µSBS) of a self-adhesive resin cement to VITA Suprinity (ZLS) and IPS e.max CAD (LD). ...Three surface conditioning protocols were performed on ZLS and LD before luting with a self-adhesive resin cement (RelyX Unicem 2, RXU): hydrofluoric acid (HF), HF + silane (HF + S), or Monobond Etch & Prime (EP). In each group, 15 cylindrical buildups of RXU were prepared on five milled bars and submitted to a µSBS test. Data were statistically analyzed with two-way ANOVA and Tukey’s post hoc test (p < 0.05). Failure modes were recorded and classified as adhesive, mixed, cohesive in resin, or ceramic, and statistically analyzed with Fisher’s exact test (p = 0.05). One additional bar per group was used for the morphological characterization of the conditioned surface by means of SEM. The material per se did not significantly influence adhesion (p = 0.744). Conditioning protocol was a significant factor: EP yielded significantly higher μSBS than HF (p = 0.005), while no significant differences emerged between EP and HF + S (p = 0.107), or HF + S and HF (p = 0.387). The material-conditioning protocol interaction was not statistically significant (p = 0.109). Significant intergroup differences were found in distribution of failure modes: mixed failures were predominant in the ZLS/EP group, while the other groups showed a prevalence of adhesive failures. The self-etching primer showed promising results in terms of immediate bond strength of a self-adhesive resin cement to lithium-silica-based glass ceramics, suggesting its alternative use to hydrofluoric acid and silane conditioning protocols.
The aim of this in vitro study was to assess conversion degree (DC), micro-hardness (MH) and bond strength of two dual-curing resin cements employed under translucent monolithic zirconia irradiated ...with different time protocols.
84 square shaped samples of 1mm thickness were prepared from high translucency zirconia blocks and divided into two groups (n=24) according to the cement employed: (1) Rely-X Ultimate; (2) Panavia SA. Each group was further divided into 3 subgroups (n=8) according to the irradiation time: (a) no light; (b) 20s; (c) 120s. Light curing was performed 60s after the sample was placed on the diamond support of a FT-IR spectrophotometer with a high power multiLED lamp. Final DC% were calculated after 10min. After 24h, Vickers Test on the cement layer was performed. The same protocol was used to lute composite cylinders in order to evaluate microshear bond-strength test. ANOVA and Bonferroni tests were performed to find differences between MH and bond-strength to zirconia, while for DC% the Scheirer–Ray–Hare two-way test was used.
The two cements reached higher DC% in subgroup (b) and (c). As concern MH, statistics showed an increase in curing time was able to improve MH significantly. Bond-strength was not affected by irradiation time only for Panavia SA.
The first null hypothesis has to be rejected since DC% and MH of the dual-cements tested were influenced by the curing time. The second null hypothesis is partially rejected since the bond strength was influenced by the curing time only for Rely-X Ultimate.
The aim of this in vitro study was to evaluate the hardness and shrinkage stress (SS) of six bulk-fill resin composites. To evaluate microhardness (MH), ten 6 mm specimens were prepared using a metal ...mold for each selected bulk-fill resin composite and irradiated from the top side for 40 s using an LED light. After 24 h of storage, Vickers MH was evaluated on the upper, lower and lateral sides of the specimens. SS evaluation was then performed with a universal machine, which evaluated the contraction force generated by a bulk-fill composite specimen placed between two metal cylinders during and after light curing. The results were evaluated with a one-way ANOVA test with a post-hoc Bonferroni test and linear regression analysis (p < 0.05). All materials showed a significant MH decrease between the top and bottom surfaces. However, the bulk-fill materials tested performed differently when considering lateral depth progression. ANOVA tests for SS evaluation showed that both SDR and Venus Bulk Fill had significantly lower stress during irradiation than other tested materials. Further, MH decrease became significantly lower from the top surface at different depths in each tested group. Among the different resins, Venus Bulk Fill and SDR showed not only inferior hardness, but also a significant reduction in SS.
The aim of the present study was to evaluate the effect of 0.1% chitosan (Ch) solution as an additional primer on the mechanical durability and enzymatic activity on dentine using an etch-and-rinse ...(E&R) adhesive and a universal self-etch (SE) adhesive. Microtensile bond strength and interfacial nanoleakage expression of the bonded interfaces for all adhesives (with or without pretreatment with 0.1% Ch solution for 1 min and air-dried for 5 seconds) were analyzed immediately and after 10,000 thermocycles. Zymograms of protein extracts from human dentine powder incubated with Optibond FL and Scotchbond Universal on untreated or Ch-treated dentine were obtained to examine dentine matrix metalloproteinase (MMP) activities. The use of 0.1% Ch solution as an additional primer in conjunction with the E&R or SE adhesive did not appear to have influenced the immediate bond strength (T0) or bond strength after thermocycling (T1). Zymography showed a reduction in MMP activities only for mineralized and demineralized dentine powder after the application of Ch. Application of 0.1% Ch solution does not increase the longevity of resin-dentine bonds. Nonetheless, the procedure appears to be proficient in reducing dentine MMP activities within groups without adhesive treatments. Further studies are required to comprehend the cross-linking of Ch with dentine collagen.
Objective: This in vitro study evaluated at baseline (T0) and over time (T12 months), the effect of a multi-mode universal adhesive compared with two experimental formulations blended with different ...concentrations of benzalkonium chloride (BAC), on bond strength and endogenous enzymatic activity.
Methods and materials: Specimens were assigned to the following groups according to the adhesive protocol: G1) All-Bond Universal (ABU) self-etch (SE); G2) ABU + 0.5% BAC SE; G3) ABU + 1% methacrylate BAC SE; G4) ABU etch-and-rinse (E&R); G5) ABU + 0.5% BAC E&R; G6) ABU + 1% methacrylate BAC E&R. Gelatin zymography was performed on dentin powder obtained from eight human third molars. Endogenous enzymatic activity within the hybrid layer was examined using in situ zymography after 24 h (T0) or 1-year storage in artificial saliva (T12). Forty intact molars were prepared for microtensile bond strength test at T0 and T12. Results were statistically analyzed with three-way ANOVA (α = 0.05).
Results: Gelatin zymography assay and in situ zymography quantification analyses indicated that all the BAC-containing formulations decreased matrix metalloproteinase expression. However, in situ zymography showed a general trend of enzymatic activity increase after aging. Microtensile bond-strength testing showed decrease in bond strength over time in all the tested groups; performances of the 1% methacrylate BAC experimental groups were worse than the control.
Conclusions: BAC-containing adhesives reduce endogenous enzymatic activity both immediately and over time. However, independently from the adhesive employed, increase in the gelatinolytic activity over time and decrease in bond strength was found (especially in the BAC + 1% methacrylate groups), probably due to impaired polymerization properties.
Clinical significance: Adhesives containing protease inhibitors are practical and efficient tools in clinical practice for enhancement of the longevity of dental restorations. However, extensive investigation of the mechanical and adhesive properties of the material is necessary prior to their clinical use.
Purpose Under thin, partial coverage restoration the proper cement thickness to be clinically employed still remains an issue. The aim of this study was to determine the failure and success rates of ...simplified lithium disilicate occlusal veneers as a function of cement thickness. The null hypothesis was that cement thickness has no effect on the fatigue resistance.Methods Sound human molars were severed in a plane parallel to the occlusal surface to create a flat dentin surface surrounded by enamel edges. Forty-five occlusal veneers 1.0 mm thick (IPS e.max CAD LT) were luted to the teeth with Multilink Automix resin cement, creating 3 experimental groups (n=15) with cement thicknesses of 50, 100, and 200 µm. The restorations were fatigue-cycled using a ball mill machine containing zirconia and stainless steel spheres. Twelve 60 min cycles were performed. Survival statistics were applied to "failure" and "success" events, comparing the three groups using a log-rank Mantel–Cox test and a log-rank test for trends (alpha = 0.05).Results The failure and success rates were not significantly influenced by cement thickness (P = 0.137 and P = 0.872, respectively); thus, the null hypothesis was accepted. However, when log-rank test for trends was applied to failure events, the tendency to have less failures with increasing thicknesses was found statistically significant (P = 0.047).Conclusions The cement thickness within the range adopted here did not have a significant effect on the failure or success rate of lithium disilicate occlusal veneers when exposed to randomized impact stresses generating fatigue phenomena.
Abstract Objective Dentinal MMPs have been claimed to contribute to the auto-degradation of collagen fibrils within incompletely resin-infiltrated hybrid layers and their inhibition may, therefore, ...slow the degradation of hybrid layer. This study aimed to determine the contribution of a synthetic MMPs inhibitor (galardin) to the proteolytic activity of dentinal MMPs and to the morphological and mechanical features of hybrid layers after aging. Methods Dentin powder obtained from human molars was treated with galardin or chlorhexidine digluconate and zymographically analyzed. Microtensile bond strength was also evaluated in extracted human teeth. Exposed dentin was etched with 35% phosphoric acid and specimens were assigned to (1) pre-treatment with galardin as additional primer for 30 s and (2) no pre-treatment. A two-step etch-and-rinse adhesive (Adper Scotchbond 1XT, 3M ESPE) was then applied in accordance with manufacturer's instructions and resin composite build-ups were created. Specimens were immediately tested for their microtensile bond strength or stored in artificial saliva for 12 months prior to being tested. Data were evaluated by two-way ANOVA and Tukey's tests ( α = 0.05). Additional specimens were prepared for interfacial nanoleakage analysis under light microscopy and TEM, quantified by two independent observers and statistically analyzed ( χ2 test, α = 0.05). Results The inhibitory effect of galardin on dentinal MMPs was confirmed by zymographic analysis, as complete inhibition of both MMP-2 and -9 was observed. The use of galardin had no effect on immediate bond strength, while it significantly decreased bond degradation after 1 year ( p < 0.05). Interfacial nanoleakage expression after aging revealed reduced silver deposits in galardin-treated specimens compared to controls ( p < 0.05). Conclusions This study confirmed that the proteolytic activity of dentinal MMPs was inhibited by the use of galardin in a therapeutic primer. Galardin also partially preserved the mechanical integrity of the hybrid layer created by a two-step etch-and-rinse adhesive after artificial aging.