Given the good performances in terms of geometrical acceptance and energy resolution, calorimeters are the best suited detectors to measure high energy cosmic rays directly in space. However, in ...order to exploit this potential, the design of calorimeters must be carefully optimized to take into account all limitations related to space missions, due mainly to the mass of the experimental apparatus. CaloCube is a three years R&D project, approved and financed by INFN in 2014, aiming to optimize the design of a space-borne calorimeter by the use of a cubic, homogeneous and isotropic geometry. In order to maximize detector performances with respect to the total mass of the apparatus, comparative studies on different scintillating materials, different sizes of crystals and different spacings among them have been performed making use of Monte Carlo simulations. In parallel to this activity, several prototypes instrumented with CsI:Tl cubic crystals have been constructed and tested with particle beams (muons, electrons, protons and ions). Both simulations and prototypes showed that the CaloCube design leads to a good particle energy resolution (< 2% for electromagnetic showers, < 40% for hadronic showers) and a good effective geometric factor (> 3:5 m2 sr for electromagnetic showers, > 2:5 m2 sr for hadronic showers). Thanks to these performances, in 5 years of operation it would be possible to measure the ux of electrons+positrons up to some tens of TeV and the uxes of protons and nuclei up to some units of PeV/nucleon, hence extending these measurements by at least one order of magnitude in energy compared to the experiments currently operating in space.
The CALorimetric Electron Telescope CALET is collecting science data on the International Space Station since October 2015 with excellent and continuous performance. Energy is measured with a deep ...homogeneous calorimeter (1.2 nuclear interaction lengths, 27 radiation lengths) preceded by an imaging pre-shower (3 radiation lengths, 1mm granularity) providing tracking and
electron/proton discrimination. Two independent sub-systems identify the charge
of the incident particle from proton to iron and above (
40). CALET measures the cosmic-ray electron + positron flux up to 20 TeV, gamma rays up to 10 TeV, and nuclei up to the PeV scale. In this paper, we report the on-orbit performance of the instrument and summarize the main results obtained during the first 5 years of operation, including the electron + positron energy spectrum and the individual spectra of protons, heavier nuclei and iron. Solar modulation and gamma-ray observations are also concisely reported, as well as transient phenomena and the search for gravitational wave counterparts.
The direct measurement of the cosmic-ray spectrum, up to the knee region, is one of the instrumental challenges for next generation space experiments. The main issue for these measurements is a ...steeply falling spectrum with increasing energy, so the physics performance of the space calorimeters are primarily determined by their geometrical acceptance and energy resolution. CaloCube is a three-year R&D project, approved and financed by INFN in 2014, aiming to optimize the design of a space-born calorimeter. The peculiarity of the design of CaloCube is its capability of detecting particles coming from any direction, and not only those on its upper surface. To ensure that the quality of the measurement does not depend on the arrival direction of the particles, the calorimeter will be designed as homogeneous and isotropic as possible. In addition, to achieve a high discrimination power for hadrons and nuclei with respect to electrons, the sensitive elements of the calorimeter need to have a fine 3-D sampling capability. In order to optimize the detector performances with respect to the total mass of the apparatus, which is the most important constraint for a space launch, a comparative study of different scintillating materials has been performed using detailed Monte Carlo simulation based on the FLUKA package. In parallel to simulation studies, a prototype consisting in 14 layers of 3 x 3 CsI(Tl) crystals per layer has been assembled and tested with particle beams. An overview of the obtained results during the first two years of the project will be presented and the future of the detector will be discussed too.
The CALorimetric Electron Telescope (CALET) is an astroparticle physics experiment installed on the International Space Station since August 2015. The CALET mission was conceived to address several ...outstanding questions of high-energy astroparticle physics, like indirect detection of dark matter, the origin of cosmic rays (CRs), their mechanisms of acceleration and galactic propagation, the presence of possible nearby astrophysical CR sources. That can be achieved by precise measurements of the fluxes of CR electrons and gamma-rays up to the unexplored region above 1 TeV, and the energy spectra and composition of CR nuclei from a few tens of GeV to hundreds of TeV. In order to perform these observations, the instrument combines a thick total absorption PWO crystal calorimeter for energy measurement, a scintillator hodoscope for charge identi cation and thin imaging tungsten-scintillating fiber calorimeter providing accurate particle tracking and complementary charge measurement.
In this paper, we will present an overview of the main CALET results based on the data collected in the first three years of the mission.
Homogeneous and isotropic calorimetry for space experiments Mori, N.; Adriani, O.; Basti, A. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2013, Letnik:
732
Journal Article
Recenzirano
Calorimetry plays an essential role in experiments observing high energy gamma and cosmic rays in space. The observational capabilities are mainly limited by the geometrical dimensions and the mass ...of the calorimeter. Since deployable mass depends on the design of the detector and the total mass of the payload, it is important to optimize the geometrical acceptance of the calorimeter for rare events, its granularity for particle identification, and its absorption depth for the measurement of the particle energy. A design of a calorimeter that could simultaneously optimize these characteristics assuming a mass limit of about 1.6t has been studied. As a result, a homogeneous calorimeter instrumented with cesium iodide (CsI) crystals was chosen as the best compromise given the total mass constraint. The most suitable geometry found is cubic and isotropic, so as to detect particles arriving from every direction in space, thus maximizing the acceptance; granularity is obtained by filling the cubic volume with small cubic CsI crystals. The total radiation length in any direction is very large, and allows for optimal electromagnetic particle identification and energy measurement, while the interaction length is at least sufficient to allow a precise reconstruction of hadronic showers. Optimal values for the size of the crystals and spacing among them have been studied. Two prototypes have been constructed and preliminary tests with high energy ion and muon beams are reported.
Future space experiments dedicated to the observation of high-energy gamma and cosmic rays will increasingly rely on a highly performing calorimetry apparatus, and their physics performance will be ...primarily determined by the geometrical dimensions and the energy resolution of the calorimeter deployed. Thus it is extremely important to optimize its geometrical acceptance, the granularity, and its absorption depth for the measurement of the particle energy with respect to the total mass of the apparatus which is the most important constraint for a space launch. The proposed design tries to satisfy these criteria while staying within a total mass budget of about 1.6 tons. Calocube is a homogeneous calorimeter instrumented with Cesium iodide (CsI) crystals, whose geometry is cubic and isotropic, so as to detect particles arriving from every direction in space, thus maximizing the acceptance; granularity is obtained by filling the cubic volume with small cubic CsI crystals. The total radiation length in any direction is more than adequate for optimal electromagnetic particle identification and energy measurement, whilst the interaction length is at least suficient to allow a precise reconstruction of hadronic showers. Optimal values for the size of the crystals and spacing among them have been studied. The design forms the basis of a three-year R&D activity which has been approved and financed by INFN. An overall description of the system, as well as results from preliminary tests on particle beams will be described.
This paper presents the results from the crosstalk and dark count rate (DCR) characterization of a 24 × 72 single photon avalanche diode (SPAD) array, fabricated in a 150 nm CMOS technology. The chip ...under test consists of a dual layer detection system developed in view of applications to charged particle tracking. A three step procedure, used for the crosstalk characterization, is presented. The crosstalk probability, taking place in 5 × 5 sub arrays built around noisy pixels, has been computed. Eventually, random telegraph signal (RTS) fluctuations in DCR, at different bias conditions, are briefly discussed.
In this paper, we present the measurement of the energy spectra of carbon and oxygen in cosmic rays based on observations with the Calorimetric Electron Telescope on the International Space Station ...from October 2015 to October 2019. Analysis, including the detailed assessment of systematic uncertainties, and results are reported. The energy spectra are measured in kinetic energy per nucleon from 10 GeV/n to 2.2 TeV/n with an all-calorimetric instrument with a total thickness corresponding to 1.3 nuclear interaction length. The observed carbon and oxygen fluxes show a spectral index change of ∼0.15 around 200 GeV/n established with a significance > 3σ. They have the same energy dependence with a constant C/O flux ratio 0.911 ± 0.006 above 25 GeV/n. The spectral hardening is consistent with that measured by AMS-02, but the absolute normalization of the flux is about 27% lower, though in agreement with observations from previous experiments including the PAMELA spectrometer and the calorimetric balloon-borne experiment CREAM.