We report results from a reanalysis of data from the Cryogenic Dark Matter Search (CDMS II) experiment at the Soudan Underground Laboratory. Data taken between October 2006 and September 2008 using ...eight germanium detectors are reanalyzed with a lowered, 2 keV recoil-energy threshold, to give increased sensitivity to interactions from weakly interacting massive particles (WIMPs) with masses below ∼10 GeV/c(2). This analysis provides stronger constraints than previous CDMS II results for WIMP masses below 9 GeV/c(2) and excludes parameter space associated with possible low-mass WIMP signals from the DAMA/LIBRA and CoGeNT experiments.
Objective: To investigate the contribution of red blood cell (RBC) methotrexate polyglutamates (MTX PGs), RBC folate polyglutamates (folate PGs), and a pharmacogenetic index to the clinical status of ...patients with rheumatoid arthritis treated with MTX. Methods: 226 adult patients treated with weekly MTX for more than 3 months were enrolled at three sites in a multicentred cross sectional observational study. Clinical status was assessed by the number of joint counts, physician’s global assessment of disease activity, and a modified Health Assessment Questionnaire (mHAQ). RBC MTX PG and folate PG metabolite levels were measured by high performance liquid chromatography fluorometry and radioassay, respectively. A composite pharmacogenetic index comprising low penetrance genetic polymorphisms in reduced folate carrier (RFC-1 G80A), AICAR transformylase (ATIC C347G), and thymidylate synthase (TSER*2/*3) was calculated. Statistical analyses were by multivariate linear regression with clinical measures as dependent variables and metabolite levels and the pharmacogenetic index as independent variables after adjustment for other covariates. Results: Multivariate analysis showed that lower RBC MTX PG levels (median 40 nmol/l) and a lower pharmacogenetic index (median 2) were associated with a higher number of joint counts, higher disease activity, and higher mHAQ (p<0.09). Multivariate analysis also established that higher RBC folate PG levels (median 1062 nmol/l) were associated with a higher number of tender and swollen joints after adjustment for RBC MTX PG levels and the pharmacogenetic index (p<0.05). Conclusion: Pharmacogenetic and metabolite measurements may be useful in optimising MTX treatment. Prospective studies are warranted to investigate the predictive value of these markers for MTX efficacy.
To evaluate the relative pain with 3 U.S. Food and Drug Administration-approved bandage soft contact lenses (SCLs) applied after photorefractive keratectomy (PRK).
Joint Warfighter Refractive Surgery ...Center, Lackland Air Force Base, Texas, USA.
Prospective comparative case series.
Patients having PRK were randomized to a senofilcon A (Acuvue Oasys), balafilcon A (Purevision), or lotrafilcon A (Air Optix) bandage SCL in each eye postoperatively. Patients were evaluated 1 and 4 days postoperatively and completed a survey rating absolute pain in each eye on a visual analog scale.
The study enrolled 54 patients. At 1 and 4 days, eyes with the senofilcon A lens had the lowest pain scores followed by eyes with the lotrafilcon A lens and then eyes with the balafilcon A lens. Averaging qualitative results from 1 and 4 days showed that eyes with the senofilcon A lens were reported as having more pain by 4% of patients, eyes with the lotrafilcon A lens by 27%, and eyes with the balafilcon A lens by 53%; 16% reported no difference (P<.001). Quantitatively, the senofilcon A lens was 40% more comfortable than the lotrafilcon A lens and 65% more comfortable than the balafilcon A lens on average. The lotrafilcon A lens was 38% more comfortable than the balafilcon A lens on average (P<.01).
There was a statistically and clinically significant difference in post-PRK pain between the 3 bandage SCLs. The senofilcon A lens caused the least pain.
Dr. Reilly is a consultant to Alcon Laboratories, Inc. and Abbott Medical Optics, Inc. but was not at the time of the study. No other author has a financial or proprietary interest in any material or method mentioned.
We report the characterization of two planet candidates detected by the Transiting Exoplanet Survey Satellite (TESS), TOI-1199 b and TOI-1273 b, with periods of 3.7 and 4.6 days, respectively. ...Follow-up observations for both targets, which include several ground-based light curves, confirmed the transit events. High-precision radial velocities from the SOPHIE spectrograph revealed signals at the expected frequencies and phases of the transiting candidates and allowed mass determinations with a precision of 8.4% and 6.7% for TOI-1199 b and TOI-1273 b, respectively. The planetary and orbital parameters were derived from a joint analysis of the radial velocities and photometric data. We find that the planets have masses of 0.239 ± 0.020 M J and 0.222 ± 0.015 M J and radii of 0.938 ± 0.025 R J and 0.99 ± 0.22 R J , respectively. The grazing transit of TOI-1273 b translates to a larger uncertainty in its radius, and hence also in its bulk density, compared to TOI-1199 b. The inferred bulk densities of 0.358 ± 0.041 g cm −3 and 0.28 ± 0.11 g cm −3 are among the lowest known for exoplanets in this mass range, which, considering the brightness of the host stars ( V ≈11 mag), render them particularly amenable to atmospheric characterization via the transit spectroscopy technique. The better constraints on the parameters of TOI-1199 b provide a transmission spectroscopy metric of 134 ± 17, making it the better suited of the two planets for atmospheric studies.
The corticosteroid choice for a lumbar transforaminal epidural steroid injection (TFESI) remains controversial. Whether to utilize particulate or nonparticulate steroid preparations for these ...injections remains an unanswered question in the literature.
To determine if a particulate or nonparticulate steroid is more effective in the treatment of electromyography (EMG)-confirmed lumbosacral radiculopathy.
Multicenter retrospective cohort study.
Two tertiary academic spine centers.
Consecutive patients, aged 18 years or older, with EMG-confirmed lumbosacral radiculopathy.
TFESI with a particulate or nonparticulate steroid to treat radicular pain within 6 months of EMG.
The primary outcome was the proportion of patients with ≥50% pain reduction on the numerical rating scale after TFESI. Secondary outcomes included mean numerical rating scale score reduction and number of repeat TFESIs. Short-term (<30 days) and intermediate (≥30 days) outcomes were compared between patients who received a TFESI with a particulate versus nonparticulate steroid.
Seventy-eight patients, with an age ± standard deviation of 56 ± 16 years and a mean symptom duration of 49 ± 71 months, were included. Forty-one patients (52%) received dexamethasone, 23 (30%) received triamcinolone, and 14 (18%) received betamethasone. There was no statistically significant difference in the proportion of patients who reported ≥50% pain reduction between the particulate and nonparticulate groups at short-term follow-up (35%; 95% confidence interval CI, 21-51 versus 28%; 95% CI, 13-43) or at intermediate follow-up (40%; 95% CI, 21-59 versus 39%; 95% CI, 19-59). There was no difference in the mean number of injections administered between groups at intermediate follow-up (P = .26).
This study demonstrates no significant differences in pain reduction or the number of repeat injections with particulate compared with nonparticulate transforaminal epidural steroid injection in patients with EMG-confirmed painful lumbosacral radiculopathy. These findings suggest a new population for whom nonparticulate steroid appears to be an appropriate first-line therapy, although confirmation with a randomized study is needed.
III.
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting ...massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg day, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross section is excluded for WIMP masses between 1.6 and 5.5 GeV/c^{2}.
We report results of a search for weakly interacting massive particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg day of data taken between July ...2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41(-0.08)(+0.20)(stat)(-0.24)(+0.28)(syst). Other known backgrounds from neutrons and 206Pb are limited to <0.13 and <0.08 events at the 90% confidence level, respectively. The exposure of this analysis is equivalent to 23.4 kg day for a recoil energy range of 7-100 keV for a WIMP of mass 10 GeV/c2. The probability that the known backgrounds would produce three or more events in the signal region is 5.4%. A profile likelihood ratio test of the three events that includes the measured recoil energies gives a 0.19% probability for the known-background-only hypothesis when tested against the alternative WIMP+background hypothesis. The highest likelihood occurs for a WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9×10(-41) cm2.
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg days was analyzed for WIMPs with mass <30 ...GeV/c(2), with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2×10(-42) cm(2) at 8 GeV/c(2). This result is in tension with WIMP interpretations of recent experiments and probes new parameter space for WIMP-nucleon scattering for WIMP masses <6 GeV/c(2).
ABSTRACT
We report the discovery of HD 110113 b (TESS object of interest-755.01), a transiting mini-Neptune exoplanet on a 2.5-d orbit around the solar-analogue HD 110113 (Teff = 5730 K). Using TESS ...photometry and High Accuracy Radial velocity Planet Searcher (HARPS) radial velocities gathered by the NCORES program, we find that HD 110113 b has a radius of 2.05 ± 0.12 R⊕ and a mass of 4.55 ± 0.62 M⊕. The resulting density of $2.90^{+0.75}_{-0.59}$ g cm−3 is significantly lower than would be expected from a pure-rock world; therefore HD 110113 b must be a mini-Neptune with a significant volatile atmosphere. The high incident flux places it within the so-called radius valley; however, HD 110113 b was able to hold on to a substantial (0.1–1 per cent) H–He atmosphere over its ∼4 Gyr lifetime. Through a novel simultaneous Gaussian process fit to multiple activity indicators, we were also able to fit for the strong stellar rotation signal with period 20.8 ± 1.2 d from the RVs and confirm an additional non-transiting planet, HD 110113 c, which has a mass of 10.5 ± 1.2 M⊕ and a period of $6.744^{+0.008}_{-0.009}$ d.