Purpose NRG Oncology/RTOG 1203 was designed to compare patient-reported acute toxicity and health-related quality of life during treatment with standard pelvic radiation or intensity-modulated ...radiation therapy (IMRT) in women with cervical and endometrial cancer. Methods Patients were randomly assigned to standard four-field radiation therapy (RT) or IMRT radiation treatment. The primary end point was change in patient-reported acute GI toxicity from baseline to the end of RT, measured with the bowel domain of the Expanded Prostate Cancer Index Composite (EPIC). Secondary end points included change in patient-reported urinary toxicity, change in GI toxicity measured with the Patient-Reported Outcome Common Terminology Criteria for Adverse Events, and quality of life measured with the Trial Outcome Index. Results From 2012 to 2015, 289 patients were enrolled, of whom 278 were eligible. Between baseline and end of RT, the mean EPIC bowel score declined 23.6 points in the standard RT group and 18.6 points in the IMRT group ( P = .048), the mean EPIC urinary score declined 10.4 points in the standard RT group and 5.6 points in the IMRT group ( P = .03), and the mean Trial Outcome Index score declined 12.8 points in the standard RT group and 8.8 points in the IMRT group ( P = .06). At the end of RT, 51.9% of women who received standard RT and 33.7% who received IMRT reported frequent or almost constant diarrhea ( P = .01), and more patients who received standard RT were taking antidiarrheal medications four or more times daily (20.4% v 7.8%; P = .04). Conclusion Pelvic IMRT was associated with significantly less GI and urinary toxicity than standard RT from the patient's perspective.
In oncology trials, the National Cancer Institute Common Terminology Criteria for Adverse Events (CTCAE) is the standard tool for reporting adverse events (AEs), but it may underreport symptoms ...experienced by patients. This analysis of the NRG Oncology RTOG 1203 compared symptom reporting by patients and clinicians during radiotherapy (RT).
Patients with cervical or endometrial cancer requiring postoperative RT were randomly assigned to standard 4-field RT or intensity-modulated RT (IMRT). Patients completed the 6-item patient-reported outcomes version of the CTCAE (PRO-CTCAE) for GI toxicity assessing abdominal pain, diarrhea, and fecal incontinence at various time points. Patients reported symptoms on a 5-point scale. Clinicians recorded these AEs as CTCAE grades 1 to 5. Clinician- and patient-reported AEs were compared using McNemar's test for rates > 0%.
Of 278 eligible patients, 234 consented and completed the PRO-CTCAE. Patients reported high-grade abdominal pain 19.1% (
< .0001), high-grade diarrhea 38.5% (
< .0001), and fecal incontinence 6.8% more frequently than clinicians. Similar effects were seen between grade ≥ 1 CTCAE toxicity and any-grade patient-reported toxicity. Between-arm comparison of patient-reported high-grade AEs revealed that at 5 weeks of RT, patients who received IMRT experienced fewer GI AEs than patients who received 4-field pelvic RT with regard to frequency of diarrhea (18.2% difference;
= .01), frequency of fecal incontinence (8.2% difference;
= .01), and interference of fecal incontinence (8.5% difference;
= .04).
Patient-reported AEs showed a reduction in symptoms with IMRT compared with standard RT, whereas clinician-reported AEs revealed no difference. Clinicians also underreported symptomatic GI AEs compared with patients. This suggests that patient-reported symptomatic AEs are important to assess in this disease setting.
JCO
The purpose of this update was to determine differences in patient-reported chronic toxicity and disease outcomes with intensity-modulated radiation therapy (IMRT) compared with conventional ...pelvic radiation. Patients with cervical and endometrial cancers who received postoperative pelvic radiation were randomly assigned to conventional radiation therapy (CRT) or IMRT. Toxicity and quality of life were assessed using Patient-Reported Outcomes version of the Common Terminology Criteria for Adverse Events, Expanded Prostate Cancer Index Composite (EPIC) bowel and urinary domains, and Functional Assessment of Cancer Therapy-General. Between 2012 and 2015, 279 eligible patients were enrolled to the study with a median follow-up of 37.8 months. There were no differences in overall survival (
= .53), disease-free survival (
= .21), or locoregional failure (
= .81). One year after RT, patients in the CRT arm experienced more high-level diarrhea frequency (5.8% IMRT
15.1% CRT,
= .042) and a greater number had to take antidiarrheal medication two or more times a day (1.2% IMRT
8.6% CRT,
= .036). At 3 years, women in the CRT arm reported a decline in urinary function, whereas the IMRT arm continued to improve (mean change in EPIC urinary score = 0.5, standard deviation = 13.0, IMRT
-6.0, standard deviation = 14.3, CRT,
= .005). In conclusion, IMRT reduces patient-reported chronic GI and urinary toxicity with no difference in treatment efficacy at 3 years.
NRG/RTOG 1203 compared 3-D conformal radiotherapy (3D CRT) to intensity-modulated radiotherapy (IMRT) in patients with endometrial or cervical cancer requiring post-operative radiotherapy after ...hysterectomy. The purpose of this study was to report the first quality-adjusted survival analysis comparing the two treatments.
NRG/RTOG 1203 randomized patients having undergone hysterectomy to either 3DCRT or IMRT. Stratification factors included RT dose, chemotherapy, and disease site. The EQ-5D, both index and visual analog scale (VAS), were obtained at baseline, 5 weeks after the start of RT, 4–6 weeks post RT and 1 and 3-years post RT. EQ-5D index and VAS scores along with quality-adjusted survival (QAS) were compared between treatment arms using the t-test at a two-sided significance level of 0.05.
NRG/RTOG 1203 enrolled 289 patients of which 236 consented to participate in the patient reported outcome (PRO) assessments. QAS was higher in women treated with IMRT, 1374 vs 1333 days (p = 0.5) compared to patients treated with 3DCRT, but this difference was not statistically different. Patients treated with IMRT had less of a decline in VAS score 5 weeks post RT, −5.04, compared to patients treated with 3DCRT, −7.48, although not statistically significant (p = 0.38).
This is the first report of the use of the EQ-5D comparing two radiotherapy techniques in the treatment of gynecologic malignancies after surgery. While there were no significant differences in QAS and VAS scores between patients who received IMRT vs. 3DCRT, RTOG 1203 was not powered to show statistical differences in these secondary endpoints.
•The first randomized clinical trial comparing two types of radiotherapy in gynecologic malignancies.•Utilities were measured a priori to calculate quality-adjusted survival between the two treatment arms.•Although not powered for these endpoints, non-statistically significant improvements were seen with the use of IMRT.
Women with endometrial or cervical cancer at risk for recurrence receive postoperative radiation therapy (RT). A patient reported outcomes (PRO) instrument to assess bowel and urinary toxicities is ...the Expanded Prostate Cancer Index Composite (EPIC), which has been validated in men with prostate cancer. As this instrument specifically measures bowel toxicity and the degree to which this is a problem, it was used in NRG Oncology/RTOG 1203 to compare intensity modulated RT (IMRT) to standard RT. This paper reports on the expanded validation of EPIC for use in women receiving pelvic RT.
In addition to the EPIC bowel domain, urinary toxicity (EPIC urinary domain), patient reported bowel toxicities (PRO-CTCAE) and quality of life (Functional Assessment of Cancer Therapy (FACT)) were completed before, during and after treatment. Sensitivity, reliability and concurrent validity were assessed.
Mean bowel and urinary scores among 278 women enrolled were significantly worse during treatment and differed between groups. Acceptable to good reliability for bowel and urinary domain scores were obtained at all time points with the exception of one at baseline. Correlations between function and bother scores within the bowel and urinary domains were consistently stronger than those across domains. Correlations between bowel domain scores and PRO-CTCAE during treatment were stronger than those with the FACT.
Correlations within and among the instruments indicate EPIC bowel and urinary domains are measuring conceptually discrete components of health. These EPIC domains are valid, reliable and sensitive instruments to measure PRO among women undergoing pelvic radiation.
•Cronbach's alpha for bowel and urinary domains at five weeks were very similar to those in the validity study with men.•Correlations suggested the bowel and urinary domains are measuring conceptually discrete components of health.•EPIC bowel and urinary domains provided valid assessment of toxicity in women undergoing postoperative radiation therapy.
Most currently available chemotherapeutic agents target rampant cell division in cancer cells, thereby affecting rapidly dividing normal cells resulting in toxic side-effects. This nonspecificity ...necessitates identification of novel cellular pathways that are reprogrammed selectively in cancer cells and can be exploited to develop pharmacologically superior and less toxic therapeutics. Despite growing awareness on dysregulation of lipid metabolism in cancer cells, targeting lipid biosynthesis is still largely uncharted territory. Herein, we report development of a novel nontoxic orally deliverable anticancer formulation of monoethanolamine (Etn) for prostate cancer by targeting the Kennedy pathway of phosphatidylethanolamine (PE) lipid biosynthesis.
We first evaluated gastrointestinal tract stability, drug-drug interaction liability, pharmacokinetic, and toxicokinetic properties of Etn to evaluate its suitability as a nontoxic orally deliverable agent. We next performed
and
experiments to investigate efficacy and mechanism of action.
Our data demonstrate that Etn exhibits excellent bioavailability, gastrointestinal tract stability, and no drug-drug interaction liability. Remarkably, orally fed Etn inhibited tumor growth in four weeks by approximately 67% in mice bearing human prostate cancer PC-3 xenografts without any apparent toxicity. Mechanistically, Etn exploits selective overexpression of choline kinase in cancer cells, resulting in accumulation of phosphoethanolamine (PhosE), accompanied by downregulation of HIF-1α that induces metabolic stress culminating into cell death.
Our study provides first evidence for the superior anticancer activity of Etn, a simple lipid precursor formulation, whose nontoxicity conforms to FDA-approved standards, compelling its clinical development for prostate cancer management.
.
To correlate the preoperative bimanual examination with ultrasound examination with regard to estimating the size of enlarged nongravid leiomyomatous uteri.
We performed a retrospective review of 161 ...patients who underwent hysterectomy for uterine leiomyoma between January 1994 and December 1994 and between July 1995 and April 1996. Uterine size was estimated clinically by bimanual examination. Ultrasound reports were reviewed. Uterine weights and dimensions in pathology reports were compared with findings on bimanual examination and ultrasonography. Body mass index (BMI) was calculated and patients were divided into two groups, one with BMIs of more than 30 and another with BMIs of less than or equal to 30.
Ultrasound examination was ordered in 111 patients (68.9%) preoperatively. There was a strong correlation between the bimanual examination findings and the ultrasound dimensions. The equation for this relationship is ultrasound length (cm)=3.68 + 0.68 x number of weeks (r=.78, P < .001). Ultrasound length also was related strongly to size given in the pathologic reports; the equation for this relationship is ultrasound length (cm)=2.94 + 0.75 x pathology length (cm) (r=.73, P < .001). The correlation between bimanual examination and ultrasound findings was similar in obese and in nonobese patients, when uterine size could be estimated.
There is a strong correlation between bimanual and ultrasound examinations with regard to determining the size of leiomyomatous uteri. Routine ultrasound is not indicated when an experienced examiner can assess uterine size. Ultrasonography may be appropriate when physical assessment is difficult, as in the case of obesity.