Assessment and Significance of Left Ventricular Mass by Cardiovascular Magnetic Resonance in Hypertrophic Cardiomyopathy Iacopo Olivotto, Martin S. Maron, Camillo Autore, John R. Lesser, Luigi Rega, ...Giancarlo Casolo, Marcello De Santis, Giovanni Quarta, Stefano Nistri, Franco Cecchi, Carol J. Salton, James E. Udelson, Warren J. Manning, Barry J. Maron, Left ventricular (LV) mass was assessed by cardiovascular magnetic resonance in 264 patients with hypertrophic cardiomyopathy (HCM), and compared with LV mass in 606 healthy control subjects. The LV mass index in HCM patients significantly exceeded that of control subjects, but was within normal range in 56 patients (21%), and only mildly increased in 18 (16%). Left ventricular mass was weakly related to maximal LV thickness (r2 = 0.38; p < 0.001). During follow-up, markedly increased LV mass index proved a more sensitive predictor of outcome than extreme maximal wall thickness. In distinction to prior perceptions, increased LV mass is not required to establish the clinical diagnosis of HCM.
Abstract
Radiomics is emerging as a promising and useful tool in cardiac magnetic resonance (CMR) imaging applications. Accordingly, the purpose of this study was to investigate, for the first time, ...the effect of image resampling/discretization and filtering on radiomic features estimation from quantitative CMR T1 and T2 mapping. Specifically, T1 and T2 maps of 26 patients with hypertrophic cardiomyopathy (HCM) were used to estimate 98 radiomic features for 7 different resampling voxel sizes (at fixed bin width), 9 different bin widths (at fixed resampling voxel size), and 7 different spatial filters (at fixed resampling voxel size/bin width). While we found a remarkable dependence of myocardial radiomic features from T1 and T2 mapping on image filters, many radiomic features showed a limited sensitivity to resampling voxel size/bin width, in terms of intraclass correlation coefficient (> 0.75) and coefficient of variation (< 30%). The estimate of most textural radiomic features showed a linear significant (p < 0.05) correlation with resampling voxel size/bin width. Overall, radiomic features from T2 maps have proven to be less sensitive to image preprocessing than those from T1 maps, especially when varying bin width. Our results might corroborate the potential of radiomics from T1/T2 mapping in HCM and hopefully in other myocardial diseases.
Radiomics and artificial intelligence have the potential to become a valuable tool in clinical applications. Frequently, radiomic analyses through machine learning methods present issues caused by ...high dimensionality and multicollinearity, and redundant radiomic features are usually removed based on correlation analysis. We assessed the effect of preprocessing-in terms of voxel size resampling, discretization, and filtering-on correlation-based dimensionality reduction in radiomic features from cardiac T1 and T2 maps of patients with hypertrophic cardiomyopathy. For different combinations of preprocessing parameters, we performed a dimensionality reduction of radiomic features based on either Pearson's or Spearman's correlation coefficient, followed by the computation of the stability index. With varying resampling voxel size and discretization bin width, for both T1 and T2 maps, Pearson's and Spearman's dimensionality reduction produced a slightly different percentage of remaining radiomic features, with a relatively high stability index. For different filters, the remaining features' stability was instead relatively low. Overall, the percentage of eliminated radiomic features through correlation-based dimensionality reduction was more dependent on resampling voxel size and discretization bin width for textural features than for shape or first-order features. Notably, correlation-based dimensionality reduction was less sensitive to preprocessing when considering radiomic features from T2 compared with T1 maps.
Novel high-sensitivity assay can detect very low levels of circulating cardiac troponin (hs-cTnT) in apparently healthy subjects. Within normal range, higher levels are associated with coronary ...artery disease (CAD) and cardiac abnormalities commonly associated to traditional risk factors (RFs) for CAD. Therefore, we investigated the relation between circulating hs-cTnT and CAD in patients with a spectrum of RF burden aiming to assess the added value of hs-cTnT to identify “outlier” patients with CAD despite a low RF burden. Hs-cTnT was measured in 525 stable patients without previous diagnosis of ischemic heart disease with 0 to 1 RF, excluded diabetes, (low-RF group, n = 263) or ≥2 RFs (multiple-RF group, n = 262) and without CAD (segment involvement score = 0) or diffuse CAD (segment involvement score >5) at coronary computed tomography angiography. Outlier patients with diffuse CAD despite low-RF burden had similar extent, severity, and plaque composition than patients with multiple RFs. Overall, hs-cTnT was measurable in 81% of patients with median value of 6.0 ng/L. In both groups, hs-cTnT concentration was higher in patients with CAD than in patients with normal coronary arteries (p <0.0001). Hs-cTnT was more accurate to detect patients with CAD in the low-RF group than in the multiple-RF group (p = 0.04). In multivariate analysis, higher level of hs-cTnT (>6 ng/L) was independently associated with CAD in low-RF group only. Despite very low circulating concentrations, hs-cTnT may identify with a good accuracy the outlier patients with diffuse CAD despite low-RF burden.
Abstract Objectives The authors performed a meta-analysis to evaluate the predictive value of late gadolinium enhancement (LGE) cardiac magnetic resonance for ventricular tachyarrhythmia in ischemic ...cardiomyopathy (ICM) and nonischemic cardiomyopathy (NICM) patients with ventricular dysfunction. Background The use of LGE to detect myocardial fibrosis and its related arrhythmic substrate is well established. Several recent studies have described the predictive value of LGE for ventricular tachyarrhythmias; however, their validity is limited by small sample size and low number of events. Methods MEDLINE and the Cochrane Library electronic databases were systematically searched to identify studies that applied LGE in ICM and NICM patients with ventricular dysfunction and reported arrhythmic clinical outcomes (sudden death, aborted sudden death, ventricular tachycardia, ventricular fibrillation, and appropriate implantable cardioverter-defibrillator ICD therapy, including antitachycardia pacing). A meta-analysis was performed to determine pooled odds ratios (ORs) for these arrhythmic events. Results Nineteen studies that evaluated 2,850 patients with 423 arrhythmic events over a mean/median follow-up of 2.8 years were identified. The composite arrhythmic endpoint was reached in 23.9% of patients with a positive LGE test (annualized event rate of 8.6%) versus 4.9% of patients with a negative LGE test (annualized event rate of 1.7%; p < 0.0001). LGE correlated with arrhythmic events in the different patient groups. In the overall population, the pooled OR was 5.62 (95% confidence interval CI: 4.20 to 7.51), with no significant differences between ICM and NICM patients. In a subgroup of 11 studies (1,178 patients) with mean ejection fraction (EF) ≤30%, the pooled OR for the arrhythmic events increased to 9.56 (95% CI: 5.63 to 16.23), with a negative likelihood ratio of 0.13 (95% CI: 0.06 to 0.30). Conclusions LGE is a powerful predictor of ventricular arrhythmic risk in patients with ventricular dysfunction, irrespective of ICM and NICM etiology. The prognostic power of LGE is particularly strong in patients with severely depressed EF, which suggests its potential to improve patient selection for ICD implantation.
Although it is generally accepted that cardiac ischemic events develop when coronary atherosclerosis (coronary artery disease CAD) has reached a critical threshold, this is true only to a first ...approximation. Indeed, there are patients with severe CAD who do not develop ischemic events; conversely, at the other extreme, individuals with minimal CAD may do. Similar exceptions to this paradigm include patients with diffuse CAD with a low risk factor (RF) profile and others with multiple RFs who develop only mild or no CAD. Therefore, the CAPIRE project was designed to investigate whether the specific study of these extreme outlier populations could provide clues for identification of yet unknown risk or protective factors for CAD and ischemic events. In the CAPIRE study, 481 subjects without previous symptoms or history of ischemic heart disease and normal left ventricular systolic function undergoing coronary computed tomography angiography have been selected based on coronary computed tomography angiography findings and cardiovascular RF profile. Therefore, in the whole population, 2 extreme outlier populations have been identified: (1) subjects with no CAD despite multiple RFs, and (2) at the opposite extreme, subjects with diffuse CAD despite a low-risk profile. Each subject has been characterized by clinical, anatomical imaging variables of CAD and baseline circulating biomarkers. Blood samples were collected and stored in a biological bank for further advanced investigations. The project is designed as a prospective, observational, international multicenter study with an initial cross-sectional analysis of clinical, imaging, and biomolecular variables in the selected groups and a longitudinal 5-year follow-up.
Effective anticancer treatments have dramatically improved the outcome of patients with cancer, but cardiac toxicity reduces their clinical efficacy in a non-negligible percentage of patients. ...Sacubitril/valsartan is a new paradigm in the treatment of chronic heart failure, with a reduced ejection fraction due to the enhancement of natriuretic peptides' properties when coupled with a blocking effect on the angiotensin II type 1 (AT1) receptors. As with other clinical conditions of heart failure with potentially reversible declines in cardiac function, a wearable cardioverter defibrillator (WCD) is a valid tool for protection against sudden death until recovery occurs. We report a case series of four patients with chemotherapy-related acute cardiac failure with severely reduced cardiac function. They were successfully treated with sacubitril/valsartan while being protected from malignant arrhythmias using a wearable cardioverter defibrillator until the recovery of cardiac function. Sacubitril/valsartan was confirmed to be effective in anthracycline-related cardiac toxicity and the wearable cardioverter defibrillator should be considered as a support tool even in the oncology patient.
Cardio-oncology has achieved a pivotal role in science, but real world data on its clinical impact are still limited.
A questionnaire was sent out to all cardio-oncology services across Italy (
= ...120). The questionnaire was made up of 28 questions divided into four blocks: (A) general information on hospitals and service, (B) the inner organization of cardio-oncology and its relationships with out-of-hospital cardiologists and general practitioners, (C) educational needs and referral guidelines, and (D) activities/specific workload.
Ninety-six out of 120 (80%) completed the questionnaire; 9.4% were cancer centers while 90.6% were general hospitals. A cardio-oncology team was present in 56% of the cancer centers and in 20% only of general hospitals, and a cardio-oncology pathway was active in 55% of cancer centers and in just 14% of the general hospitals. Relationships with out-of-hospital cardiologists and general practitioners were lacking. The guidelines of reference were ESC and ANMCO/AIOM. Patients receiving anthracycline chemotherapy underwent scheduled monitoring by means of echocardiography in 58% of cases. Routine use of cardiac damage biomarkers was overall low, ranging from 22 to 33% while the use of global longitudinal strain reached 44%.
Italian cardio-oncology showed a growing influence on clinical practice but still has room for improvement. Cardio-oncology teams are still scarce, and the application of dedicated paths is poor. The need for specific training has been highlighted.