We present the first Ge-based constraints on sub-MeV /c2 dark matter (DM) particles interacting with electrons using a 33.4 g Ge cryogenic detector with a 0.53 electron-hole pair (rms) resolution, ...operated underground at the Laboratoire Souterrain de Modane. Competitive constraints are set on the DM-electron scattering cross section, as well as on the kinetic mixing parameter of dark photons down to 1 eV / c2. In particular, the most stringent limits are set for dark photon DM in the 6 to 9 eV / c2 range. These results demonstrate the high relevance of Ge cryogenic detectors for the search of DM-induced eV-scale electron signals.
We make use of the EDELWEISS-III array of germanium bolometers to search for electron interactions at the keV scale induced by phenomena beyond the Standard Model. A 90% C.L. lower limit is set on ...the electron lifetime decaying to invisibles, ?>1.2×1024 years. We investigate the emission of axions or axionlike particles (ALPs) by the Sun, constraining the coupling parameters gae<1.1×10?11 and gae×gaNeff<3.5×10?17 at 90% C.L. in the massless limit. We also directly search for the absorption of bosonic dark matter particles that would constitute our local galactic halo. Limits are placed on the couplings of ALPs or hidden photon dark matter in the mass range 0.8–500 keV/c2. Prospects for searching for dark matter particles with masses down to 150 eV/c2 using improved detectors are presented.
We report on a dark matter search for a Weakly Interacting Massive Particle (WIMP) in the mass range
m
χ
∈
4
,
30
GeV
/
c
2
with the EDELWEISS-III experiment. A 2D profile likelihood analysis is ...performed on data from eight selected detectors with the lowest energy thresholds leading to a combined fiducial exposure of 496 kg-days. External backgrounds from
γ
- and
β
-radiation, recoils from
206
Pb
and neutrons as well as detector intrinsic backgrounds were modelled from data outside the region of interest and constrained in the analysis. The basic data selection and most of the background models are the same as those used in a previously published analysis based on boosted decision trees (BDT)
1
. For the likelihood approach applied in the analysis presented here, a larger signal efficiency and a subtraction of the expected background lead to a higher sensitivity, especially for the lowest WIMP masses probed. No statistically significant signal was found and upper limits on the spin-independent WIMP-nucleon scattering cross section can be set with a hypothesis test based on the profile likelihood test statistics. The 90 % C.L. exclusion limit set for WIMPs with
m
χ
=
4
GeV
/
c
2
is
1.6
×
10
-
39
cm
2
, which is an improvement of a factor of seven with respect to the BDT-based analysis. For WIMP masses above
15
GeV
/
c
2
the exclusion limits found with both analyses are in good agreement.
The EDELWEISS-II Collaboration has completed a direct search for WIMP dark matter with an array of ten 400-g cryogenic germanium detectors in operation at the Laboratoire Souterrain de Modane. The ...combined use of thermal phonon sensors and charge collection electrodes with an interleaved geometry enables the efficient rejection of γ-induced radioactivity as well as near-surface interactions. A total effective exposure of 384 kg d has been achieved, mostly coming from fourteen months of continuous operation. Five nuclear recoil candidates are observed above 20 keV, while the estimated background is 3.0 events. The result is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 4.4×10−8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints are also set on models where the WIMP-nucleon scattering is inelastic.
In the context of direct searches of sub-GeV Dark Matter particles with germanium detectors, the EDELWEISS collaboration has tested a new technique to tag ionizing events using NbSi transition edge ...athermal phonon sensors. The emission of the athermal phonons generated by the Neganov-Trofimov-Luke effect associated with the drift of electrons and holes through the detectors is used to tag ionization events generated in specific parts of the detector localized in front of the NbSi sensor and to reject by more than a factor 5 (at 90% C.L.) the background from heat-only events that dominates the spectrum above 3 keV. This method is able to improve by a factor 2.8 the previous limit on spin-independent interactions of 1 GeV/c2 WIMPs obtained with the same detector and data set but without this tagging technique.
High Impedance TES Bolometers for EDELWEISS Marnieros, S.; Armengaud, E.; Arnaud, Q. ...
Journal of low temperature physics,
06/2023, Letnik:
211, Številka:
5-6
Journal Article
Recenzirano
The EDELWEISS collaboration aims for direct detection of light dark matter using germanium cryogenic detectors with low threshold phonon sensor technologies and efficient charge readout designs. We ...describe here the development of Ge bolometers equipped with high impedance thermistors based on a Nb
x
Si
1−x
TES alloy. High aspect ratio spiral designs allow the TES impedance to match with JFET or HEMT front-end amplifiers. We detail the behavior of the superconducting transition properties of these sensors and the detector optimization in terms of sensitivity to a-thermal phonons. We report preliminary results of a 200 g Ge detector that was calibrated using
71
Ge activation by neutrons at the LSM underground laboratory.
The EDELWEISS-II Collaboration has performed a direct search for WIMP dark matter with an array of ten 400 g heat-and-ionization cryogenic detectors equipped with interleaved electrodes for the ...rejection of near-surface events. Six months of continuous operation at the Laboratoire Souterrain de Modane have been achieved. The observation of one nuclear recoil candidate above 20 keV in an effective exposure of 144 kg d is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 1.0×10−7 pb is excluded at 90% CL for a WIMP mass of 80 GeV/c2. This result demonstrates for the first time the very high background rejection capabilities of these simple and robust detectors in an actual WIMP search experiment.
The EDELWEISS Collaboration has performed a search for dark matter particles with masses below the GeV scale with a 33.4-g germanium cryogenic detector operated in a surface lab. The energy deposits ...were measured using a neutron-transmutation-doped Ge thermal sensor with a 17.7 eV (rms) baseline heat energy resolution leading to a 60 eV analysis energy threshold. Despite a moderate lead shielding and the high-background environment, the first sub-GeV spin-independent dark matter limit based on a germanium target has been achieved. The experiment provides the most stringent, nuclear-recoil-based, above-ground limit on spin-independent interactions above 600 MeV/c2. The experiment also provides the most stringent limits on spin-dependent interactions with protons and neutrons below 1.3 GeV/c2. Furthermore, the dark matter search results were studied in the context of strongly interacting massive particles, taking into account Earth-shielding effects, for which new regions of the available parameter space have been excluded. Finally, the dark matter search has also been extended to interactions via the Migdal effect, resulting for the first time in the exclusion of particles with masses between 45 and 150 MeV/c2 with spin-independent cross sections ranging from 10−29 to 10−26 cm2.
A multi-tiered data structure, analysis toolkit and data processing management system has been constructed using ROOT and CouchDB. This system is well suited for experiments that acquire many ...computer files of raw data over the course of months or years, that are distributed to different computing centers and further reduced in size by several steps of data processing. Data handling for experiments searching for rare events extracted from digitized pulse traces typically fit this description. An implementation of this system has been constructed for the EDELWEISS-III experiment and is described here in some detail. This solution may also serve as a prototype system for the proposed EURECA experiment.