The tumor microenvironment (TME) consists of a heterogenous cellular milieu that can influence cancer cell behavior. Its characteristics have an impact on treatments such as immunotherapy. These ...features can be revealed with single-cell RNA sequencing (scRNA-seq). We hypothesized that scRNA-seq analysis of gastric cancer together with paired normal tissue and peripheral blood mononuclear cells (PBMC) would identify critical elements of cellular deregulation not apparent with other approaches.
scRNA-seq was conducted on seven patients with gastric cancer and one patient with intestinal metaplasia. We sequenced 56,167 cells comprising gastric cancer (32,407 cells), paired normal tissue (18,657 cells), and PBMCs (5,103 cells). Protein expression was validated by multiplex immunofluorescence.
Tumor epithelium had copy number alterations, a distinct gene expression program from normal, with intratumor heterogeneity. Gastric cancer TME was significantly enriched for stromal cells, macrophages, dendritic cells (DC), and Tregs. TME-exclusive stromal cells expressed distinct extracellular matrix components than normal. Macrophages were transcriptionally heterogenous and did not conform to a binary M1/M2 paradigm. Tumor DCs had a unique gene expression program compared to PBMC DCs. TME-specific cytotoxic T cells were exhausted with two heterogenous subsets. Helper, cytotoxic T, Treg, and NK cells expressed multiple immune checkpoint or co-stimulatory molecules. Receptor-ligand analysis revealed TME-exclusive intercellular communication.
Single-cell gene expression studies revealed widespread reprogramming across multiple cellular elements in the gastric cancer TME. Cellular remodeling was delineated by changes in cell numbers, transcriptional states, and intercellular interactions. This characterization facilitates understanding of tumor biology and enables identification of novel targets including for immunotherapy.
Potassium‐ion batteries (PIBs) are promising alternatives to lithium‐ion batteries because of the advantage of abundant, low‐cost potassium resources. However, PIBs are facing a pivotal challenge to ...develop suitable electrode materials for efficient insertion/extraction of large‐radius potassium ions (K+). Here, a viable anode material composed of uniform, hollow porous bowl‐like hard carbon dual doped with nitrogen (N) and phosphorus (P) (denoted as N/P‐HPCB) is developed for high‐performance PIBs. With prominent merits in structure, the as‐fabricated N/P‐HPCB electrode manifests extraordinary potassium storage performance in terms of high reversible capacity (458.3 mAh g−1 after 100 cycles at 0.1 A g−1), superior rate performance (213.6 mAh g−1 at 4 A g−1), and long‐term cyclability (205.2 mAh g−1 after 1000 cycles at 2 A g−1). Density‐functional theory calculations reveal the merits of N/P dual doping in favor of facilitating the adsorption/diffusion of K+ and enhancing the electronic conductivity, guaranteeing improved capacity, and rate capability. Moreover, in situ transmission electron microscopy in conjunction with ex situ microscopy and Raman spectroscopy confirms the exceptional cycling stability originating from the excellent phase reversibility and robust structure integrity of N/P‐HPCB electrode during cycling. Overall, the findings shed light on the development of high‐performance, durable carbon anodes for advanced PIBs.
A viable anode material composed of nitrogen/phosphorus co‐doped hollow porous bowl‐like hard carbon is developed for potassium ion batteries. The resulting anode manifests prominent merits in structure, endowing it with extraordinary K+ storage capability. The K+ storage mechanisms are revealed through in‐depth studies by combining in situ TEM studies, ex situ microscopic, and Raman spectroscopy in conjunction with DFT calculations.
Ferromagnetic pipes are widely used in the oil and gas industry. They are subject to cracks due to corrosion, pressure, and fatigue. It is significant to detect cracks for the safety of pipes. A ...residual magnetic field testing (RMFT) system is developed for crack detection in ferromagnetic pipes. Based on this background, a detection probe based on an array of tunneling magneto-resistive (TMR) sensors and permanent magnets is exploited. The probe is able to partially magnetize the pipe wall and collect magnetic signals simultaneously. First, a theoretical analysis of RMFT is presented. The physics principle of RMFT is introduced, and a finite element model is built. In the finite element simulations, the effects of the crack length and depth on the RMFT signal are analyzed, and the signal characteristics are selected to represent the crack size. Next, the validated experiments are conducted to demonstrate the feasibility of the proposed RMFT method in this paper.
We aimed to evaluate the clinical efficacy of the single-stage posterior surgical treatment for patients of lumbar brucella spondylitis combined with spondylolisthesis. In this study, we performed a ...retrospective analysis of 16 patients with lumbar brucellosis spondylitis combined with spondylolisthesis from January 2015 to January 2019. All patients underwent single-stage posterior lumbar debridement, reduction, interbody fusion, and instrumentation. Preoperative and postoperative of the visual analog scale (VAS), the Oswestry disability index (ODI), erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) were compared. In addition, the spondylolisthesis reduction rate, reduction loss rate, interbody fusion rate, and complication rate were recorded. VAS, ODI, ESR, and CRP were conducted with repeated analysis of variance data at different follow-ups. The postoperative follow-up was 12-36 months, with an average of (25.0 ± 8.1) months. VAS, ODI, ESR, and CRP were significantly better at 2-week and 1-year follow-up than preoperative results (P = 0.000, respectively). In addition, 1 year after the operation, VAS, ODI, ESR, and CRP showed a significant improvement (P = 0.000, respectively). The average spondylolisthesis reduction in 2 weeks after operation was (91.2 ± 6.7)%, and the median reduction loss rate in 1 year after operation was 8.0 (5.0, 9.8)%. At the last follow-up, all patients achieved interbody fusion, no loosening and fracture of instrumentation were found, and no recurrence happened. Single-stage posterior operation for lumbar debridement, reduction, interbody fusion, and instrumentation is beneficial for treating lumbar brucellosis spondylitis combined with spondylolisthesis. Furthermore, the reconstruction of spinal stability may relieve pain, heal lesions, and improve patients' living.
The piezoelectric cantilever resonator is used widely in many fields because of its perfect design, easy-to-control process, easy integration with the integrated circuit. The tip displacement and ...resonance frequency are two important characters of the piezoelectric cantilever resonator and many models are used to characterize them. However, these models are only suitable for the piezoelectric cantilever with the same width layers. To accurately characterize the piezoelectric cantilever resonators with different width layers, a novel model is proposed for predicting the tip displacement and resonance frequency. The results show that the model is in good agreement with the finite element method (FEM) simulation and experiment measurements, the tip displacement error is no more than 6%, the errors of the first, second, and third-order resonance frequency between theoretical values and measured results are 1.63%, 1.18%, and 0.51%, respectively. Finally, a discussion of the tip displacement of the piezoelectric cantilever resonator when the second layer is null, electrode, or silicon oxide (SiO
) is presented, and the utility of the model as a design tool for specifying the tip displacement and resonance frequency is demonstrated. Furthermore, this model can also be extended to characterize the piezoelectric cantilever with n-layer film or piezoelectric doubly clamped beam.
At present, traditional magnetic field sensors have shortcomings such as large size, complex structure, poor anti-interference ability, and low sensitivity, which are limited in large-scale ...applications. The magneto-optical sensor has the characteristics of small size, high-integration, stable and reliable in extreme working environment and high sensitivity, which can effectively overcome the above defects and easier to convert it into application products. In this paper, we summarize the magneto-optical sensor based on different used materials, include magnetostrictive materials and magneto-optical materials. We analyzed the sensing mechanisms of these two magneto-optical sensors in detail. The characteristics, structure and performance of magneto-optical sensors are analyzed, the current research progress is summarized, the future development direction of magneto-optical sensors is proposed, and the challenges and development prospects of magneto-optical sensors are analyzed.
•The development of optical fiber sensor in recent years is summarized.•The magneto-optic sensor devices based on magnetostrictive materials and artificial micro-nano structures are summarized and prospected.•The working principles of different types of magneto-optic sensing devices are analyzed.•The current applications and shortcomings of magneto-optic sensing devices are summarized.
Display omitted
In the past two decades, biomimetic tactile sensing technology has been a hot spot in academia. It has prospective applications in many fields such as medical treatment, health monitoring, robot ...tactile feedback, and human–machine interaction. With the rapid development of magnetic sensors, biomimetic tactile sensing technology based on magnetic sensors (which are called magnetic tactile sensors below) has been widely studied in recent years. In order to clarify the development status and application characteristics of magnetic tactile sensors, this paper firstly reviews the magnetic tactile sensors from three aspects: the types of magnetic sensors, the sources of magnetic field, and the structures of sensitive bodies used in magnetic tactile sensors. Secondly, the development of magnetic tactile sensors in four applications of robot precision grasping, texture characterization, flow velocity measurement, and medical treatment is introduced in detail. Finally, this paper analyzes technical difficulties and proposes prospective research directions for magnetic tactile sensors.
Objective
It remains unclear whether primary tumor resection improves survival in patients with metastatic Siewert type II adenocarcinoma of the esophagogastric junction (AEG). Therefore, our study ...attempted to investigate the prognostic value of primary tumor resection on metastatic AEG.
Methods
In total, 4200 patients diagnosed with metastatic AEG were retrieved from the Surveillance, Epidemiology, and End Results (SEER) database from 2004 to 2015. Patients were categorized into two groups according to the performance of primary tumor resection. Pearson’s chi-square test, Kaplan–Meier survival curve, and Cox regression analysis were conducted in this study. In addition, propensity-score matching was conducted to match 323 patients who received primary tumor resection and another 323 patients without.
Results
Multivariate Cox regression analysis demonstrated that primary tumor resection was a significant prognostic factor in patients with metastatic AEG before matching. Moreover, in the matched cohort, metastatic AEG patients receiving primary tumor resection had significantly longer overall survival (hazard ratio HR: .54, 95% confidence interval CI: .46–.64, P < .001) and cancer-specific survival (HR: .53, 95% CI: .45–.63, P < .001). Subgroup analysis similarly revealed that primary tumor resection was significantly associated with better survival in most subgroups.
Conclusion
The present population-based study identified that primary tumor resection led to significantly superior survival in patients with metastatic AEG. These findings are likely to contribute to the development of individualized therapy in metastatic AEG.
Flexible wearable sweat sensors allow continuous, real-time, noninvasive detection of sweat analytes, provide insight into human physiology at the molecular level, and have received significant ...attention for their promising applications in personalized health monitoring. Electrochemical sensors are the best choice for wearable sweat sensors due to their high performance, low cost, miniaturization, and wide applicability. Recent developments in soft microfluidics, multiplexed biosensing, energy harvesting devices, and materials have advanced the compatibility of wearable electrochemical sweat-sensing platforms. In this review, we summarize the potential of sweat for medical detection and methods for sweat stimulation and collection. This paper provides an overview of the components of wearable sweat sensors and recent developments in materials and power supply technologies and highlights some typical sensing platforms for different types of analytes. Finally, the paper ends with a discussion of the challenges and a view of the prospective development of this exciting field.