This Letter reports the first measurement of the 235U $\bar{ν}$e energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9 m from the 85 MWth highly ...enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678±304(stat) $\bar{ν}$e-induced inverse beta decays, the largest sample from HEU fission to date, 99% of which are attributed to 235U. Despite broad agreement, comparison of the Huber 235U model to the measured spectrum produces a χ2/ndf=51.4/31, driven primarily by deviations in two localized energy regions. The measured 235U spectrum shape is consistent with a deviation relative to prediction equal in size to that observed at low-enriched uranium power reactors in the $\bar{ν}$e energy region of 5–7 MeV.
We report the measurement of muons and muon-induced phosphorescence in DM-Ice17, a NaI(Tl) direct detection dark matter experiment at the South Pole. Muon interactions in the crystal are identified ...by their observed pulse shape and large energy depositions. The measured muon rate in DM-Ice17 is 2.93+ or -0.04 mu /crystal/day with a modulation amplitude of 12.3+ or -1.7%, consistent with expectation. Following muon interactions, we observe long-lived phosphorescence in the NaI(Tl) crystals with a decay time of 5.5+ or -0.5s. The prompt energy deposited by a muon is correlated to the amount of delayed phosphorescence, the brightest of which consist of tens of millions of photons. These photons are distributed over tens of seconds with a rate and arrival timing that do not mimic a scintillation signal above 2keV sub(ee). While the properties of phosphorescence vary among individual crystals, the annually modulating signal observed by DAMA cannot be accounted for by phosphorescence with the characteristics observed in DM-Ice17.
► We describe a dark matter experiment using NaI crystals deployed in South Pole ice. ► We explore the sensitivity of a 250kg NaI dark matter experiment. ► A 250kg NaI experiment will investigate the ...annual modulation reported by DAMA/LIBRA.
Astrophysical observations and cosmological data have led to the conclusion that nearly one quarter of the Universe consists of dark matter. Should dark matter interact with nucleons, it has been postulated that an observable signature of dark matter is an annual modulation in the rate of dark matter-nucleon interactions taking place in an Earth-bound experiment. To search for this effect, we introduce the concept for a new dark matter experiment using NaI scintillation detectors deployed deep in the South Pole ice. This experiment complements dark matter search efforts in the Northern Hemisphere and will investigate the observed annual modulation in the DAMA/LIBRA and DAMA/NaI experiments. The unique location will permit the study of background effects correlated with seasonal variations and the surrounding environment. This paper describes the experimental concept and explores the sensitivity of a 250kg NaI experiment at the South Pole.
Abstract
IceCube, a cubic-kilometer neutrino detector, was built at the South Pole using a hot-water drill system. Deep holes were drilled into the Antarctic ice sheet and filled with highly ...sensitive optical instrumentation. For the hot-water drilling, a computer model was developed to predict the hole sizes and hole lifetimes during construction. The goal was to predict ultimate size and freezeback rates based on water flow rate and temperature, drill speed, ice temperature and ream parameters (for a secondary operation where hot water continues to flow as the drill is withdrawn). This model proved to be very successful. It increased confidence that the holes would remain open long enough after drilling to allow the deployment of the necessary instrumentation. It also allowed for a decrease, over the course of the project, in the amount of overdrilling that was used as a margin against a too-rapid freeze-in. This resulted in significant fuel savings.
LUX-ZEPLIN (LZ) is a next-generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. ...Using a two-phase xenon detector with an active mass of 7 tonnes, LZ will search primarily for low-energy interactions with weakly interacting massive particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo. In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector. For a 1000 live day run using a 5.6-tonne fiducial mass, LZ is projected to exclude at 90% confidence level spin-independent WIMP-nucleon cross sections above 1.4 × 10−48 cm2 for a 40 GeV/c2 mass WIMP. Additionally, a 5 σ discovery potential is projected, reaching cross sections below the exclusion limits of recent experiments. For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of 2.3 × 10−43 cm2 (7.1 × 10−42 cm2) for a 40 GeV/c2 mass WIMP is expected. With underground installation well underway, LZ is on track for commissioning at SURF in 2020.
The PROSPECT reactor antineutrino experiment Ashenfelter, J.; Balantekin, A.B.; Baldenegro, C. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
04/2019, Letnik:
922
Journal Article
Recenzirano
Odprti dostop
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is designed to make both a precise measurement of the antineutrino spectrum from a highly-enriched uranium reactor and to probe ...eV-scale sterile neutrinos by searching for neutrino oscillations over meter-long baselines. PROSPECT utilizes a segmented6Li-doped liquid scintillator detector for both efficient detection of reactor antineutrinos through the inverse beta decay reaction and excellent background discrimination. PROSPECT is a movable 4-ton antineutrino detector covering distances of 7m to 13m from the High Flux Isotope Reactor core. It will probe the best-fit point of the ν̄e disappearance experiments at 4σ in 1 year and the favored regions of the sterile neutrino parameter space at more than 3σ in 3 years. PROSPECT will test the origin of spectral deviations observed in recent θ13 experiments, search for sterile neutrinos, and address the hypothesis of sterile neutrinos as an explanation of the reactor anomaly. This paper describes the design, construction, and commissioning of PROSPECT and reports first data characterizing the performance of the PROSPECT antineutrino detector.
This Letter reports the first scientific results from the observation of antineutrinos emitted by fission products of ^{235}U at the High Flux Isotope Reactor. PROSPECT, the Precision Reactor ...Oscillation and Spectrum Experiment, consists of a segmented 4 ton ^{6}Li-doped liquid scintillator detector covering a baseline range of 7-9 m from the reactor and operating under less than 1 m water equivalent overburden. Data collected during 33 live days of reactor operation at a nominal power of 85 MW yield a detection of 25 461±283 (stat) inverse beta decays. Observation of reactor antineutrinos can be achieved in PROSPECT at 5σ statistical significance within 2 h of on-surface reactor-on data taking. A reactor model independent analysis of the inverse beta decay prompt energy spectrum as a function of baseline constrains significant portions of the previously allowed sterile neutrino oscillation parameter space at 95% confidence level and disfavors the best fit of the reactor antineutrino anomaly at 2.2σ confidence level.
A high precision calibration of the nonlinearity in the energy response of the Daya Bay Reactor Neutrino Experiment’s antineutrino detectors is presented in detail. The energy nonlinearity originates ...from the particle-dependent light yield of the scintillator and charge-dependent electronics response. The nonlinearity model is constrained by γ calibration points from deployed and naturally occurring radioactive sources, the β spectrum from 12B decays, and a direct measurement of the electronics nonlinearity with a new flash analog-to-digital converter readout system. Less than 0.5% uncertainty in the energy nonlinearity calibration is achieved for positrons of kinetic energies greater than 1 MeV.