A detailed study of hadronic interactions is presented using data recorded with the highly granular CALICE silicon–tungsten electromagnetic calorimeter. Approximately 350,000 selected π− events at ...energies between 2 and 10GeV have been studied. The predictions of several physics models available within the GEANT4 simulation tool kit are compared to this data. A reasonable overall description of the data is observed; the Monte Carlo predictions are within 20% of the data, and for many observables much closer. The largest quantitative discrepancies are found in the longitudinal and transverse distributions of reconstructed energy.
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45×10×3mm3 plastic scintillator ...strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6GeV/c. The prototype׳s performance is presented in terms of the linearity and resolution of the energy measurement. These results represent an important milestone in the development of highly granular calorimeters using scintillator strip technology. A number of possible design improvements were identified, which should be implemented in a future detector of this type. This technology is being developed for a future linear collider experiment, aiming at the precise measurement of jet energies using particle flow techniques.
A prototype silicon–tungsten electromagnetic calorimeter (ECAL) for an international linear collider (ILC) detector was installed and tested during summer and autumn 2006 at CERN. The detector had ...6480 silicon pads of dimension
1
×
1
cm
2
. Data were collected with electron beams in the energy range 6–45
GeV. The analysis described in this paper focuses on electromagnetic shower reconstruction and characterises the ECAL response to electrons in terms of energy resolution and linearity. The detector is linear to within approximately the 1% level and has a relative energy resolution of
(
16.53
±
0.14
(
stat
)
±
0.4
(
syst
)
)
/
E
(
GeV
)
⊕
(
1.07
±
0.07
(
stat
)
±
0.1
(
syst
)
)
(
%
)
. The spatial uniformity and the time stability of the ECAL are also addressed.