The aim of our study was to investigate the safety and efficacy of the LDV Z8 femtosecond laser in cataract surgery compared to the conventional procedure.
This prospective study was performed at the ...Swiss Eye Research Foundation, Eye Clinic ORASIS, Reinach, Switzerland. The study included 130 eyes from 130 patients: 68 treated with femtosecond laser-assisted cataract surgery (FLACS) using the FEMTO LDV Z8 and 62 treated with conventional phacoemulsification. Capsulotomy and lens fragmentation in the laser group were performed with the FEMTO LDV Z8 femtosecond laser system, which employs a new, low-energy, high repetition rate laser process for cataract surgery. In the conventional group, the capsulotomy was performed by a cystotome, and lens fragmentation was achieved by the stop-and-chop.
Ease of phacoemulsification (on a 4-point scale), the completeness of capsulotomy (on a 10-point scale), effective phacoemulsification time (seconds), uncorrected distance visual acuity (UCVA), best spectacle-corrected distance visual acuity (BSCVA), spherical equivalent (SE), and safety of the procedure were evaluated. The total follow-up time was three months.
FLACS with the FEMTO LDV Z8 system was characterized by complete and reproducible capsulotomy and highly effective lens fragmentation. Postoperative visual outcomes were excellent, and the safety of the procedure was optimal.
Femtosecond laser-assisted cataract surgery has the potential to make critical steps of cataract surgery easier and safer, and reduce endothelial cell loss, thus, improving postoperative outcomes. ...This study compared FLACS with the conventional method in terms of endothelial cells behavior, clinical outcomes, and capsulotomy precision.
In a single-center, randomized controlled study, 130 patients with cataracta senilis received FLACS or conventional cataract surgery.
A significant endothelial cell loss was observed postoperatively, compared to the preoperative values in both groups. The endothelial cell counts was significantly better in the FLACS group in cataract grade 2 (
= 0.048) patients, compared to conventionally at 4 weeks. The effective phaco time was notably shorter in grade 2 of the FLACS group (
= 0.007) compared to the conventional. However, no statistically significant differences were found for the whole sample, including all cataract grades, due to the overall cataract density in the FLACS group being significantly higher (2.60 ± 0.58,
< 0.001) as compared to conventional methods (2.23 ± 0.42).
Low energy FLACS provides a better result compared to endothelial cell loss, size, and shape variations, as well as in effective phaco time within certain cataract grade subgroups. A complete comparison between two groups was not possible because of the higher cataract grade in the FLACS. FLACS displayed a positive effect on endothelial cell preservation and was proven to be much more precise.
The recent advances in optical sources and detectors have opened up new opportunities for sensing and imaging techniques which can be successfully used in biomedical and healthcare applications. This ...book, entitled ‘Optical Methods in Sensing and Imaging for Medical and Biological Applications’, focuses on various aspects of the research and development related to these areas. The book will be a valuable source of information presenting the recent advances in optical methods and novel techniques, as well as their applications in the fields of biomedicine and healthcare, to anyone interested in this subject.
Phacoemulsification is a widely used surgical method in cataract surgery with a high energy ultrasound source. The viscoelastic is considered to be tissue protective. The aim of this study is to ...investigate during surgery the impact of using viscoelastic versus no viscoelastic on clinical outcomes, potential complications and effect on endothelial cell density. The study group included 64 patients, who were subjected to phacoemulsification using balanced salt solution (BSS). Control group consisted of 62 patients, who underwent phacoemulsification using Hyaloronic acid 1% Healon 1%. Student's
-test was applied for statistical analysis. The simulations of temperature changes during phacoemulsification were performed by COMSOL Multiphysics software. In the BSS group, a mean endothelial cell loss (ECL) of 4.5% was measured one month postoperatively, while in the Healon group ECL was 5.3%. Data analysis showed no significant difference in ECL between the groups (Student's
-test,
= 0.8). No significant difference was observed in endothelial cell morphology and IOP between the two groups pre- and postoperatively (all
> 0.05). The modeling of thermo fluid dynamics showed that the heating of the cornea is slightly less when Healon was used as irrigation fluid. The phacoemulsification technique can be performed by an experienced surgeon with viscoelastics or continuous anterior chamber (AC) irrigation on the same level of safety regarding endothelial cell damage, providing equally satisfying clinical outcomes.
It is known that pterygia above a certain size cause astigmatism and other aberrations of the human cornea and thus impair the quality of vision. Exclusive Sr-/Ytt-90 beta irradiation is a highly ...effective treatment for primary pterygia. The aim of this retrospective study is to determine the extent to which higher order corneal aberrations are affected by this treatment.
Evaluation of corneal topographies and wavefront aberration data of 20 primary pterygia patients generated before and at different points in time in the first year after irradiation. Additionally, the size of the pterygium was measured.
The study showed a significant increase in coma and triple leaf aberrations in pterygia with a horizontal length of 2 mm and more. It was also found that a pterygium size greater than 2 mm significantly induces astigmatism. Both phenomena reduce visual quality. In none of the patients could a pterygium recurrence be detected after irradiation.
If the pterygium size is less than 2 mm, early exclusive Sr/Ytt-90 beta irradiation can be recommended. If the size is more than 2 mm, a pterygium excision 6 months after beta irradiation can be discussed.
Planning astigmatic correction is a complex task. Biomechanical simulation models are useful for predicting the effects of the physical procedure on the cornea. Algorithms based on these models allow ...preoperative planning and simulate the outcome of patient-specific treatment. The objective of this study was to develop a customised optimisation algorithm and determine the predictability of astigmatism correction by femtosecond laser arcuate incisions. In this study, biomechanical models and Gaussian approximation curve calculations were used for surgical planning. Thirty-four eyes with mild astigmatism were included, and corneal topographies were evaluated before and after femtosecond laser-assisted cataract surgery with arcuate incisions. The follow-up time was up to 6 weeks. Retrospective data showed a significant reduction in postoperative astigmatism. A total of 79.4% showed a postoperative astigmatic value less than 1 D. Clinical refraction was significantly reduced from -1.39 ± 0.79 D preoperatively to -0.86 ± 0.67 D postoperatively (
0.02). A positive reduction in topographic astigmatism was also observed (
< 0.00). The best-corrected visual acuity increased postoperatively (
< 0.001). We can conclude that customised simulations based on corneal biomechanics are a valuable tool for correcting mild astigmatism with corneal incisions in cataract surgery to improve postoperative visual outcomes.
A prospective comparative study assessing the importance of the intra-operative dynamic rotational tracking-especially in the treatment of astigmatisms in corneal refractive Excimer laser ...correction-concerning clinical outcomes is presented. The cyclotorsion from upright to supine position was measured using iris image comparison. The Group 1 of patients was additionally treated with cyclorotational control and Group 2 only with X-Y control. Significant differences were observed between the groups regarding the mean postoperative cylinder refraction (
< 0.05). The mean cyclotorsion can be calculated to 3.75° with a standard deviation of 3.1°. The total range of torsion was from -14.9° to +12.6°. Re-treatment rate was 2.2% in Group 1 and 8.2% in Group 2, which is highly significant (
< 0.01). The investigation confirms that the dynamic rotational tracking system used for LASIK results in highly predictable refraction quality with significantly less postoperative re-treatments.
This paper presents the analysis of electrical and dielectric properties of the yttrium-doped nickel ferrite nano-powders synthesized using the co-precipitation method. Impedance and dielectric ...measurements have been carried out as a function of frequency at different temperatures from 200 to 25 °C in the range of 0.1 kHz–1 MHz. In order to investigate the conduction mechanism and highlight the role of yttrium doping in different concentrations, impedance spectroscopy was employed. The obtained data were analyzed in terms of equivalent circuits made of resistor and capacitor components describing the contributions from different electrical active regions in a material. Further, this study highlights the importance of a single constant phase element (CPE) in the description of dispersion behavior of the impedance response of the investigated samples in the given frequency range. The use of this technique enabled the characterization of grain and grain boundaries contribution in overall conductivity mechanism. The dielectric dispersion nature of all investigated materials is reflected in this study. Very high values of the real part of permittivity at low frequencies are assigned to space-charge polarization. The dependence of the real part of dielectric permittivity values of the yttrium content was also discussed. Doping with yttrium in different concentrations that reflects in different electric and dielectric responses is concluded in this study. The greatest change is noticed for the sample with the minimum dopant content for a x = 0.05 atomic percent share of yttrium. To reveal the potential role of more than one ion contribution to the overall relaxation process in investigated compounds, a modified Debye’s equation was utilized.
The power density of femtosecond lasers and exposure time to the tissue are crucial for a successful procedure in terms of safety and precision. The reduction of the pulse duration allows reducing ...the quantity of the energy to be delivered to the tissue for disruption with strongly diminished mechanical and thermal collateral damage. The cutting effect of ultra-short pulses is very precise, minimally traumatic, safe, and predictable. Future developments will lead to further energy reductions to achieve optical breakdowns. However, the pulse length cannot be shortened arbitrarily because below 100 fs nonlinear effects can change the process in an unfavorable way. Compared to manual-conventional cataract surgery, femtosecond laser-assisted cataract surgery (FLACS) shows many advantages in clinical application, especially with regard to precision and tissue protection. The femtosecond laser has become particularly important and has made the overall procedure safer when we deal with complex cataract cases such as subluxated lenses. We provide an overview of the evolution of femtosecond laser technology for use in refractive and cataract surgeries. This article describes the advantages of available laser platforms with ultrashort pulses and mainly focuses on the technical and physical backgrounds of ophthalmic surgery technologies.
Laser Assisted in Situ Keratomileusis (LASIK) is a proven treatment method for corneal refractive surgery. Surgically induced higher order optical aberrations were a major reason why the method was ...only rarely used to treat presbyopia, an age-related near-vision loss. In this study, a novel customization algorithm for designing multifocal ablation patterns, thereby minimizing induced optical aberrations, was used to treat 36 presbyopic subjects. Results showed that most candidates went from poor visual acuity to uncorrected 20/20 vision or better for near (78%), intermediate (92%), and for distance (86%) vision, six months after surgery. All subjects were at 20/25 or better for distance and intermediate vision, and a majority (94%) were also better for near vision. Even though further studies are necessary, our results suggest that the employed methodology is a safe, reliable, and predictable refractive surgical treatment for presbyopia.