A novel technique for testing the timing properties of scintillators is presented. The technique is based on transient absorption (TA) induced in a scintillating material by a selective excitation of ...the activator ion. A figure of merit to assess the timing properties of scintillators is suggested. This parameter was estimated for a set of cerium doped lutetium–yttrium oxyorthosilicate (LYSO:Ce) bars, which have been fabricated for Barrel Timing Layer sensor of Compact Muon Solenoid detector (CMS BTL) and exhibited different timing properties, and compared with the results obtained by conventional coincidence time resolution (CTR) measurements. The figure of merit applied for the tested bars shows a strong correlation (Pearson's correlation coefficient R = 0.95) with the CTR. These results suggest that the TA technique could be used as an experimental method to expand in a complementary way the extensive qualification procedure of LYSO:Ce crystals that will be performed for the production of the CMS BTL detector.
•Coincidence time resolution correlates with activator population rise time.•Population rise time can be probed by transient absorption in femtosecond domain.•Transient absorption can be exploited for testing of scintillator timing properties.
The CUPID-0 experiment searches for double beta decay using cryogenic calorimeters with double (heat and light) read-out. The detector, consisting of 24 ZnSe crystals 95 Formula omitted enriched in ...Formula omittedSe and two natural ZnSe crystals, started data-taking in 2017 at Laboratori Nazionali del Gran Sasso. We present the search for the neutrino-less double beta decay of Formula omittedSe into the 0 Formula omitted, 2 Formula omitted and 2 Formula omitted excited states of Formula omittedKr with an exposure of 5.74 kg Formula omittedyr (2.24 Formula omitted10 Formula omitted emitters Formula omittedyr). We found no evidence of the decays and set the most stringent limits on the widths of these processes: Formula omitted( Formula omittedSe Formula omittedKr Formula omitted)8.55 Formula omitted10 Formula omitted yr Formula omitted, Formula omitted ( Formula omitted Se Formula omitted Kr Formula omitted) Formula omitted yr Formula omitted, Formula omitted( Formula omittedSe Formula omittedKr Formula omitted)8.25 Formula omitted10 Formula omitted yr Formula omitted (90 Formula omitted credible interval).
CUORE, an array of 988 TeO
2
bolometers, is about to be one of the most sensitive experiments searching for neutrinoless double-beta decay. Its sensitivity could be further improved by removing the ...background from
α
radioactivity. A few years ago it was pointed out that the signal from
β
s can be tagged by detecting the emitted Cherenkov light, which is not produced by
α
s. In this paper we confirm this possibility. For the first time we measured the Cherenkov light emitted by a CUORE crystal, and found it to be 100 eV at the
Q
-value of the decay. To completely reject the
α
background, we compute that one needs light detectors with baseline noise below 20 eV RMS, a value which is 3–4 times smaller than the average noise of the bolometric light detectors we are using. We point out that an improved light detector technology must be developed to obtain TeO
2
bolometric experiments able to probe the inverted hierarchy of neutrino masses.
The LUCIFER project aims at deploying the first array of enriched scintillating bolometers for the investigation of neutrinoless double-beta decay of Formula: see textSe. The matrix which embeds the ...source is an array of ZnSe crystals, where enriched Formula: see textSe is used as decay isotope. The radiopurity of the initial components employed for manufacturing crystals, that can be operated as bolometers, is crucial for achieving a null background level in the region of interest for double-beta decay investigations. In this work, we evaluated the radioactive content in 2.5 kg of 96.3 % enriched Formula: see textSe metal, measured with a high-purity germanium detector at the Gran Sasso deep underground laboratory. The limits on internal contaminations of primordial decay chain elements of Formula: see textTh, Formula: see textU and Formula: see textU are respectively: Formula: see text61, Formula: see text110 and Formula: see text74 Formula: see textBq/kg at 90 % C.L. The extremely low-background conditions in which the measurement was carried out and the high radiopurity of the Formula: see textSe allowed us to establish the most stringent lower limits on the half-lives of the double-beta decay of Formula: see textSe to 0Formula: see text, 2Formula: see text and 2Formula: see text excited states of Formula: see textKr of 3.4Formula: see text10Formula: see text, 1.3Formula: see text10Formula: see text and 1.0Formula: see text10Formula: see text y, respectively, with a 90 % C.L.
The LUCIFER project aims at deploying the first array of enriched scintillating bolometers for the investigation of neutrinoless double-beta decay of Se-82. The matrix which embeds the source is an ...array of ZnSe crystals, where enriched Se-82 is used as decay isotope. The radiopurity of the initial components employed for manufacturing crystals, that can be operated as bolometers, is crucial for achieving a null background level in the region of interest for double-beta decay investigations. In this work, we evaluated the radioactive content in 2.5 kg of 96.3 % enriched Se-82 metal, measured with a high-purity germanium detector at the Gran Sasso deep underground laboratory. The limits on internal contaminations of primordial decay chain elements of Th-232, U-238 and U-235 are respectively: <61,<110 and <74 mu Bq/kg at 90 % C.L. The extremely low-background conditions in which the measurement was carried out and the high radiopurity of the Se-82 allowed us to establish the most stringent lower limits on the half-lives of the double-beta decay of Se-82 to 0(+)(1), 2(2)(+) and 2(1)(+) excited states of Kr-82 of 3.4.10(22), 1.3.10(22) and 1.0.10(22) y, respectively, with a 90 % C.L.