In the years 2009–2013 the Large Hadron Collider (LHC) has been operated with the top beam energies of 3.5 and 4 TeV per proton (from 2012) instead of the nominal 7 TeV. The currents in the ...superconducting magnets were reduced accordingly. To date only seventeen beam-induced quenches have occurred; eight of them during specially designed quench tests, the others during injection. There has not been a single beam-induced quench during normal collider operation with stored beam. The conditions, however, are expected to become much more challenging after the long LHC shutdown. The magnets will be operating at near nominal currents, and in the presence of high energy and high intensity beams with a stored energy of up to 362 MJ per beam. In this paper we summarize our efforts to understand the quench levels of LHC superconducting magnets. We describe beam-loss events and dedicated experiments with beam, as well as the simulation methods used to reproduce the observable signals. The simulated energy deposition in the coils is compared to the quench levels predicted by electrothermal models, thus allowing one to validate and improve the models which are used to set beam-dump thresholds on beam-loss monitors for run 2.
As a result of the foreseen increase in the luminosity of the Large Hadron Collider, the discrimination between the collision products and possible magnet quench-provoking beam losses of the primary ...proton beams is becoming more critical for safe accelerator operation. We report the results of ongoing research efforts targeting the upgrading of the monitoring system by exploiting Beam Loss Monitor detectors based on semiconductors located as close as possible to the superconducting coils of the triplet magnets. In practice, this means that the detectors will have to be immersed in superfluid helium inside the cold mass and operate at 1.9K. Additionally, the monitoring system is expected to survive 20 years of LHC operation, resulting in an estimated radiation fluence of 1×1016 proton/cm2, which corresponds to a dose of about 2MGy. In this study, we monitored the signal degradation during the in situ irradiation when silicon and single-crystal diamond detectors were situated in the liquid/superfluid helium and the dependences of the collected charge on fluence and bias voltage were obtained. It is shown that diamond and silicon detectors can operate at 1.9K after 1×1016p/cm2 irradiation required for application as BLMs, while the rate of the signal degradation was larger in silicon detectors than in the diamond ones. For Si detectors this rate was controlled mainly by the operational mode, being larger at forward bias voltage.
•Silicon and diamond detectors are proposed for beam loss monitoring at LHC.•The first in situ radiation test of Si and diamond detectors at 1.9K is described.•Both diamond and silicon detectors survived after 1×1016p/cm2 irradiation at 1.9K.•The rate of Si detectors degradation depends on bias polarity and is larger at Vforw.•Sensitivity of Si detectors irradiated to 1×1016p/cm2 is independent on resistivity.
Diamond devices have now become ubiquitous in the LHC experiments, finding applications in beam background monitoring and luminosity measuring systems. This sensor material is now maturing to the ...point that the large pads in existing diamond detectors are being replaced by highly granular tracking devices, in both pixel and strip configurations, for detector systems that will be used in Run II at the LHC and beyond. The RD42 collaboration has continued to seek out additional diamond manufacturers and quantify the limits of the radiation tolerance of this material. The ATLAS experiment has recently installed, and is now commissioning a fully-fledged pixel tracking detector system based on diamond sensors. Finally, RD42 has recently demonstrated the viability of 3D biased diamond sensors that can be operated at very low voltages with full charge collection. These proceedings describe all of these advances.
A 3D diamond detector for particle tracking Artuso, M.; Bachmair, F.; Bartosik, M. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
07/2016, Letnik:
824
Journal Article
Recenzirano
Odprti dostop
In the present study, results towards the development of a 3D diamond sensor are presented. Conductive channels are produced inside the sensor bulk using a femtosecond laser. This electrode geometry ...allows full charge collection even for low quality diamond sensors. Results from testbeam show that charge is collected by these electrodes. In order to understand the channel growth parameters, with the goal of producing low resistivity channels, the conductive channels produced with a different laser setup are evaluated by Raman spectroscopy.
A quench, the transition of a conductor from the superconducting to the normal conducting state, occurs irreversibly in the accelerator magnets if one of the three parameters: temperature, magnetic ...field or current density exceeds a critical value. Energy deposited in the superconductor by the particle beams provokes quenches detrimental for the accelerator operation. In particular if particles impacting on the vacuum chamber and their secondary showers depose energy in the magnet coils. The large hadron collider (LHC) nominal beam intensity is 3.2 ldr 10 14 protons. A quench occurs if a fraction of the order of 10 7 protons per second is lost locally. A network model is used to simulate the thermodynamic behavior of the magnets. The heat flow in the network model was validated with measurements performed in the CERN magnet test facility. A steady state heat flow was introduced in the coil by using the quench heaters implemented in the LHC magnets. The value of the heat source current is determined by the network model and the magnet coil current which is required to quench the coil is predicted accordantly. The measured and predicted value comparison is regarded as a sensitive test of the method.