Untangling glycaemia and mortality in critical care Uyttendaele, Vincent; Dickson, Jennifer L; Shaw, Geoffrey M ...
Critical care (London, England),
06/2017, Letnik:
21, Številka:
1
Journal Article, Web Resource
Recenzirano
Odprti dostop
Hyperglycaemia is associated with adverse outcomes in the intensive care unit, and initial studies suggested outcome benefits of glycaemic control (GC). However, subsequent studies often failed to ...replicate these results, and they were often unable to achieve consistent, safe control, raising questions about the benefit or harm of GC as well as the nature of the association of glycaemia with mortality and clinical outcomes. In this study, we evaluated if non-survivors are harder to control than survivors and determined if glycaemic outcome is a function of patient condition and eventual outcome or of the glycaemic control provided.
Clinically validated, model-based, hour-to-hour insulin sensitivity (SI) and its hour-to-hour variability (%ΔSI) were identified over the first 72 h of therapy in 145 patients (119 survivors, 26 non-survivors). In hypothesis testing, we compared distributions of SI and %ΔSI in 6-hourly blocks for survivors and non-survivors. In equivalence testing, we assessed if differences in these distributions, based on blood glucose measurement error, were clinically significant.
SI level was never equivalent between survivors and non-survivors (95% CI of percentage difference in medians outside ±12%). Non-survivors had higher SI, ranging from 9% to 47% higher overall in 6-h blocks, and this difference became statistically significant as glycaemic control progressed. %ΔSI was equivalent between survivors and non-survivors for all 6-hourly blocks (95% CI of difference in medians within ±12%) and decreased in general over time as glycaemic control progressed.
Whereas non-survivors had higher SI levels, variability was equivalent to that of survivors over the first 72 h. These results indicate survivors and non-survivors are equally controllable, given an effective glycaemic control protocol, suggesting that glycaemia level and variability, and thus the association between glycaemia and outcome, are essentially determined by the control provided rather than by underlying patient or metabolic condition.
Critical care, like many healthcare areas, is under a dual assault from significantly increasing demographic and economic pressures. Intensive care unit (ICU) patients are highly variable in response ...to treatment, and increasingly aging populations mean ICUs are under increasing demand and their cohorts are increasingly ill. Equally, patient expectations are growing, while the economic ability to deliver care to all is declining. Better, more productive care is thus the big challenge. One means to that end is personalised care designed to manage the significant inter- and intra-patient variability that makes the ICU patient difficult. Thus, moving from current "one size fits all" protocolised care to adaptive, model-based "one method fits all" personalised care could deliver the required step change in the quality, and simultaneously the productivity and cost, of care. Computer models of human physiology are a unique tool to personalise care, as they can couple clinical data with mathematical methods to create subject-specific models and virtual patients to design new, personalised and more optimal protocols, as well as to guide care in real-time. They rely on identifying time varying patient-specific parameters in the model that capture inter- and intra-patient variability, the difference between patients and the evolution of patient condition. Properly validated, virtual patients represent the real patients, and can be used in silico to test different protocols or interventions, or in real-time to guide care. Hence, the underlying models and methods create the foundation for next generation care, as well as a tool for safely and rapidly developing personalised treatment protocols over large virtual cohorts using virtual trials. This review examines the models and methods used to create virtual patients. Specifically, it presents the models types and structures used and the data required. It then covers how to validate the resulting virtual patients and trials, and how these virtual trials can help design and optimise clinical trial. Links between these models and higher order, more complex physiome models are also discussed. In each section, it explores the progress reported up to date, especially on core ICU therapies in glycemic, circulatory and mechanical ventilation management, where high cost and frequency of occurrence provide a significant opportunity for model-based methods to have measurable clinical and economic impact. The outcomes are readily generalised to other areas of medical care.
Glucose management in intensive care unit (ICU) patients has been a matter of debate for almost two decades. Compared to intermittent monitoring systems, continuous glucose monitoring (CGM) can offer ...benefit in the prevention of severe hyperglycemia and hypoglycemia by enabling insulin infusions to be adjusted more rapidly and potentially more accurately because trends in glucose concentrations can be more readily identified. Increasingly, it is apparent that a single glucose target/range may not be optimal for all patients at all times and, as with many other aspects of critical care patient management, a personalized approach to glucose control may be more appropriate. Here we consider some of the evidence supporting different glucose targets in various groups of patients, focusing on those with and without diabetes and neurological ICU patients. We also discuss some of the reasons why, despite evidence of benefit, CGM devices are still not widely employed in the ICU and propose areas of research needed to help move CGM from the research arena to routine clinical use.
There is considerable physiological and clinical evidence of harm and increased risk of death associated with dysglycemia in critical care. However, glycemic control (GC) currently leads to increased ...hypoglycemia, independently associated with a greater risk of death. Indeed, recent evidence suggests GC is difficult to safely and effectively achieve for all patients. In this review, leading experts in the field discuss this evidence and relevant data in diabetology, including the artificial pancreas, and suggest how safe, effective GC can be achieved in critically ill patients in ways seeking to mimic normal islet cell function. The review is structured around the specific clinical hurdles of: understanding the patient's metabolic state; designing GC to fit clinical practice, safety, efficacy, and workload; and the need for standardized metrics. These aspects are addressed by reviewing relevant recent advances in science and technology. Finally, we provide a set of concise recommendations to advance the safety, quality, consistency, and clinical uptake of GC in critical care. This review thus presents a roadmap toward better, more personalized metabolic care and improved patient outcomes.
Respiratory mechanics models can aid in optimising patient-specific mechanical ventilation (MV), but the applications are limited to fully sedated MV patients who have little or no spontaneously ...breathing efforts. This research presents a time-varying elastance (E(drs)) model that can be used in spontaneously breathing patients to determine their respiratory mechanics.
A time-varying respiratory elastance model is developed with a negative elastic component (E(demand)), to describe the driving pressure generated during a patient initiated breathing cycle. Data from 22 patients who are partially mechanically ventilated using Pressure Support (PS) and Neurally Adjusted Ventilatory Assist (NAVA) are used to investigate the physiology relevance of the time-varying elastance model and its clinical potential. E(drs) of every breathing cycle for each patient at different ventilation modes are presented for comparison.
At the start of every breathing cycle initiated by patient, E(drs) is < 0. This negativity is attributed from the E(demand) due to a positive lung volume intake at through negative pressure in the lung compartment. The mapping of E(drs) trajectories was able to give unique information to patients' breathing variability under different ventilation modes. The area under the curve of E(drs) (AUCE(drs)) for most patients is > 25 cmH2Os/l and thus can be used as an acute respiratory distress syndrome (ARDS) severity indicator.
The E(drs) model captures unique dynamic respiratory mechanics for spontaneously breathing patients with respiratory failure. The model is fully general and is applicable to both fully controlled and partially assisted MV modes.
The Authors In light of the COVID-19 pandemic, this common-sense approach was recently clarified in a SCCM-ASA-AARC-AACN-ASPF-CHEST consensus statement on the Society of Critical Care Medicine (SCCM) ...website 1: ‘We recommend that clinicians do not attempt to ventilate more than one patient with a single ventilator while any clinically proven, safe, and reliable therapy remains available (ie, in a dire, temporary emergency)’ 1. In-parallel is a critical point, as inspiration and expiration all take place at the same time, so there is thus no change to respiratory rate (RR) and tidal volume or driving pressure are adjusted for the number of patients. ...one-way expiratory valves and filters prevent rebreathing and cross-contamination.
Surges of COVID-19 infections have led to insufficient supply of mechanical ventilators (MV), resulting in rationing of MV care. In-parallel, co-mechanical ventilation (Co-MV) of multiple patients is ...a potential solution. However, due to lack of testing, there is currently no means to match ventilation requirements or patients, with no guidelines to date. In this research, we have developed a model-based method for patient matching for pressure control mode MV.
The model-based method uses a single-compartment lung model (SCM) to simulate the resultant tidal volume of patient pairs at a set ventilation setting. If both patients meet specified safe ventilation criteria under similar ventilation settings, the actual mechanical ventilator settings for Co-MV are determined via simulation using a double-compartment lung model (DCM). This method allows clinicians to analyse Co-MV in silico, before clinical implementation.
The proposed method demonstrates successful patient matching and MV setting in a model-based simulation as well as good discrimination to avoid mismatched patient pairs. The pairing process is based on model-based, patient-specific respiratory mechanics identified from measured data to provide useful information for guiding care. Specifically, the matching is performed via estimation of MV delivered tidal volume (mL/kg) based on patient-specific respiratory mechanics. This information can provide insights for the clinicians to evaluate the subsequent effects of Co-MV. In addition, it was also found that Co-MV patients with highly restrictive respiratory mechanics and obese patients must be performed with extra care.
This approach allows clinicians to analyse patient matching in a virtual environment without patient risk. The approach is tested in simulation, but the results justify the necessary clinical validation in human trials.
Patient-specific lung mechanics during mechanical ventilation (MV) can be identified from measured waveforms of fully ventilated, sedated patients. However, asynchrony due to spontaneous breathing ...(SB) effort can be common, altering these waveforms and reducing the accuracy of identified, model-based, and patient-specific lung mechanics.
Changes in patient-specific lung elastance over a pressure-volume (PV) loop, identified using hysteresis loop analysis (HLA), are used to detect the occurrence of asynchrony and identify its type and pattern. The identified HLA parameters are then combined with a nonlinear mechanics hysteresis loop model (HLM) to extract and reconstruct ventilated waveforms unaffected by asynchronous breaths. Asynchrony magnitude can then be quantified using an energy-dissipation metric, E
, comparing PV loop area between model-reconstructed and original, altered asynchronous breathing cycles. Performance is evaluated using both test-lung experimental data with a known ground truth and clinical data from four patients with varying levels of asynchrony.
Root mean square errors for reconstructed PV loops are within 5% for test-lung experimental data, and 10% for over 90% of clinical data. E
clearly matches known asynchrony magnitude for experimental data with RMS errors < 4.1%. Clinical data performance shows 57% breaths having E
> 50% for Patient 1 and 13% for Patient 2. Patient 3 only presents 20% breaths with E
> 10%. Patient 4 has E
= 0 for 96% breaths showing accuracy in a case without asynchrony.
Experimental test-lung validation demonstrates the method's reconstruction accuracy and generality in controlled scenarios. Clinical validation matches direct observations of asynchrony in incidence and quantifies magnitude, including cases without asynchrony, validating its robustness and potential efficacy as a clinical real-time asynchrony monitoring tool.
Derivative based a-priori structural identifiability analyses of mathematical models can offer valuable insight into the identifiability of model parameters. However, these analyses are only capable ...of a binary confirmation of the mathematical distinction of parameters and a positive outcome can begin to lose relevance when measurement error is introduced. This article presents an integral based method that allows the observation of the identifiability of models with two-parameters in the presence of assay error.
The method measures the distinction of the integral formulations of the parameter coefficients at the proposed sampling times. It can thus predict the susceptibility of the parameters to the effects of measurement error. The method is tested in-silico with Monte Carlo analyses of a number of insulin sensitivity test applications.
The method successfully captured the analogous nature of identifiability observed in Monte Carlo analyses of a number of cases including protocol alterations, parameter changes and differences in participant behaviour. However, due to the numerical nature of the analyses, prediction was not perfect in all cases.
Thus although the current method has valuable and significant capabilities in terms of study or test protocol design, additional developments would further strengthen the predictive capability of the method. Finally, the method captures the experimental reality that sampling error and timing can negate assumed parameter identifiability and that identifiability is a continuous rather than discrete phenomenon.
Background:
Continuous glucose monitoring (CGM) devices, with their 1-5 min measurement interval, allow blood glucose (BG) concentration dynamics to be captured more frequently and less invasively ...than traditional BG measures. One cohort CGM could provide insight is athletes. This study investigates what impact their heightened energy expenditure and dietary intake may have on their ability to achieve optimal BG.
Methods:
Ten subelite athletes (resting HR<60 bpm, training>6 hrs per week) were recruited. Two Ipro2 CGM devices (Medtronic Minimed, Northridge, CA) were inserted into the abdomen and remained in place for ~6 days. Time in band was calculated as the percentage of CGM BG measurements with in the 4.0-6.0 mmol/L. Fasting glucose was calculated using CGM calibration BG measurements and postprandial glucose response was also calculated using the CGM values.
Results:
4/10 athletes studied spent more than 70% of the total monitoring time above 6.0 mmol/L even with the 2-hour period after meals is excluded. Fasting BG was also in the ADA defined prediabetes range for 3/10 athletes. Only 1 participant spent substantial time below 4.0 mmol/L which was largely due to significantly lower energy intake compared to recommendations.
Conclusions:
Contrary to expectations high BG appears to be more of a concern for athletes then low BG even in those with the highest energy expenditure and consuming below the recommended carbohydrate intake. This study warrants further investigation on the recommended diets and the BG of athletes to better determine the causes and impact of this hyperglycemia on overall athlete health.