Background
Leaks are considered one of the major complications of laparoscopic sleeve gastrectomy (LSG) with a reported rate up to 7 %. Drainage of the collection coupled with SEMS deployment is the ...most frequent treatment. Its success is variable and burdened by high morbidity and not irrelevant mortality. The aim of this paper is to suggest and establish a new approach by endoscopic internal drainage (EID) for the management of leaks.
Methods
Since March 2013, 67 patients presenting leak following LSG were treated with deployment of double pigtail plastic stents across orifice leak, positioning one end inside the collection and the other end in remnant stomach. The aim of EID is to internally drain the collection and at the same time promote leak healing.
Results
Double pigtails stent were successfully delivered in 66 out of 67 patients (98.5 %). Fifty patients were cured by EID after a mean time of 57.5 days and an average of 3.14 endoscopic sessions. Two died for event not related to EID. Nine are still under treatment; five failure had been registered. Six patients developed late stenosis treated endoscopically.
Conclusions
EID proved to be a valid, curative, and safe mini-invasive approach for treatment of leaks following SG. EID achieves complete drainage of perigastric collections and stimulates mucosal growth over the stent. EID is well tolerated, allows early re-alimentation, and it is burdened by fewer complications than others technique. Long-term follow-up confirms good outcomes with no motility or feeding alterations.
Standard neuroimaging fails in defining the anatomy of the substantia nigra and has a marginal role in the diagnosis of Parkinson disease. Recently 7T MR target imaging of the substantia nigra has ...been useful in diagnosing Parkinson disease. We performed a comparative study to evaluate whether susceptibility-weighted angiography can diagnose Parkinson disease with a 3T scanner.
Fourteen patients with Parkinson disease and 13 healthy subjects underwent MR imaging examination at 3T and 7T by using susceptibility-weighted angiography. Two expert blinded observers and 1 neuroradiology fellow evaluated the 3T and 7T images of the sample to identify substantia nigra abnormalities indicative of Parkinson disease. Diagnostic accuracy and intra- and interobserver agreement were calculated separately for 3T and 7T acquisitions.
Susceptibility-weighted angiography 7T MR imaging can diagnose Parkinson disease with a mean sensitivity of 93%, specificity of 100%, and diagnostic accuracy of 96%. 3T MR imaging diagnosed Parkinson disease with a mean sensitivity of 79%, specificity of 94%, and diagnostic accuracy of 86%. Intraobserver and interobserver agreement was excellent at 7T. At 3T, intraobserver agreement was excellent for experts, and interobserver agreement ranged between good and excellent. The less expert reader obtained a diagnostic accuracy of 89% at 3T.
Susceptibility-weighted angiography images obtained at 3T and 7T differentiate controls from patients with Parkinson disease with a higher diagnostic accuracy at 7T. The capability of 3T in diagnosing Parkinson disease might encourage its use in clinical practice. The use of the more accurate 7T should be supported by a dedicated cost-effectiveness study.
Amyotrophic lateral sclerosis is a progressive motor neuron disorder that involves degeneration of both upper and lower motor neurons. In patients with amyotrophic lateral sclerosis, pathologic ...studies and ex vivo high-resolution MR imaging at ultra-high field strength revealed the co-localization of iron and activated microglia distributed in the deep layers of the primary motor cortex. The aims of the study were to measure the cortical thickness and evaluate the distribution of iron-related signal changes in the primary motor cortex of patients with amyotrophic lateral sclerosis as possible in vivo biomarkers of upper motor neuron impairment.
Twenty-two patients with definite amyotrophic lateral sclerosis and 14 healthy subjects underwent a high-resolution 2D multiecho gradient-recalled sequence targeted on the primary motor cortex by using a 7T scanner. Image analysis consisted of the visual evaluation and quantitative measurement of signal intensity and cortical thickness of the primary motor cortex in patients and controls. Qualitative and quantitative MR imaging parameters were correlated with electrophysiologic and laboratory data and with clinical scores.
Ultra-high field MR imaging revealed atrophy and signal hypointensity in the deep layers of the primary motor cortex of patients with amyotrophic lateral sclerosis with a diagnostic accuracy of 71%. Signal hypointensity of the deep layers of the primary motor cortex correlated with upper motor neuron impairment (r = -0.47; P < .001) and with disease progression rate (r = -0.60; P = .009).
The combined high spatial resolution and sensitivity to paramagnetic substances of 7T MR imaging demonstrate in vivo signal changes of the cerebral motor cortex that resemble the distribution of activated microglia within the cortex of patients with amyotrophic lateral sclerosis. Cortical thinning and signal hypointensity of the deep layers of the primary motor cortex could constitute a marker of upper motor neuron impairment in patients with amyotrophic lateral sclerosis.
Amyotrophic Lateral Sclerosis (ALS) is a progressive neurological disorder that entails degeneration of both upper and lower motor neurons. The primary motor cortex (M1) in patients with upper motor ...neuron (UMN) impairment is pronouncedly hypointense in Magnetic Resonance (MR) T2* contrast. In the present study, 3D gradient-recalled multi-echo sequences were used on a 7 Tesla MR system to acquire T2*-weighted images targeting M1 at high spatial resolution. MR raw data were used for Quantitative Susceptibility Mapping (QSM). Measures of magnetic susceptibility correlated with the expected concentration of non-heme iron in different regions of the cerebral cortex in healthy subjects. In ALS patients, significant increases in magnetic susceptibility co-localized with the T2* hypointensity observed in the middle and deep layers of M1. The magnetic susceptibility, hence iron concentration, of the deep cortical layers of patients' M1 subregions corresponding to Penfield's areas of the hand and foot in both hemispheres significantly correlated with the clinical scores of UMN impairment of the corresponding limbs. QSM therefore reflects the presence of iron deposits related to neuroinflammatory reaction and cortical microgliosis, and might prove useful in estimating M1 iron concentration, as a possible radiological sign of severe UMN burden in ALS patients.
Background and Aims
The originality of this retrospective study relies on the evaluation of the effectiveness of the endoscopic internal drainage (EID) according to the type of fistula.
Methods
The ...type of fistula was classified initially according to a CT scan with oral opacification: fistula without a communicating abscess (type I), fistula with a communicating abscess (type II), and fistula with an abscessed sub- and sus-diaphragmatic communicating collection (type III). Treatment algorithm consisted of the insertion of a nasojejunal feeding tube (NJFT) for type I fistulas and the placement of a NJFT with EID with or without surgical drainage for types II and III.
Results
Forty-nine patients were included. The clinical success rate with fistula healing was 100% in group I, 96% in group II, and 12% for group III (
p
= 0.001). Mean time for diagnosis of the fistula was significantly higher in type III (
p
= 0.04). The mean estimated size of the defect was higher in type II, 11.2 mm and III, 10 mm versus type I, 2.8 mm (
p
= 0.001). The average number of scheduled endoscopic sessions were 2, 2.7, and 5.2 for types I, II, and III, respectively (
p
= 0.001). The number of unscheduled reinterventions was also significantly higher in type III (
p
= 0.03). The NJFT was left in place for a significantly longer duration in type III (136 days) compared to types I (3, 13) and II (49)
p
= 0.001.
Conclusion
This study shows that proper characterization of the type of fistula before the endoscopic treatment of post-sleeve fistulas improves the efficacy of the endoscopic treatment.
BACKGROUND AND PURPOSE:Amyotrophic lateral sclerosis is a neurodegenerative disease involving the upper and lower motor neurons. In amyotrophic lateral sclerosis, pathologic changes in the primary ...motor cortex include Betz cell depletion and the presence of reactive iron-loaded microglia, detectable on 7T MR images as atrophy and T2*-hypointensity. Our purposes were the following: 1) to investigate the signal hypointensity-to-thickness ratio of the primary motor cortex as a radiologic marker of upper motor neuron involvement in amyotrophic lateral sclerosis with a semiautomated method at 3T, 2) to compare 3T and 7T results, and 3) to evaluate whether semiautomated measurement outperforms visual image assessment.MATERIALS AND METHODS:We investigated 27 patients and 13 healthy subjects at 3T, and 19 patients and 18 healthy subjects at 7T, performing a high-resolution 3D multiecho T2*-weighted sequence targeting the primary motor cortex. The signal hypointensity-to-thickness ratio of the primary motor cortex was calculated with a semiautomated method depicting signal intensity profiles of the cortex. Images were also visually classified as “pathologic” or “nonpathologic” based on the primary motor cortex signal intensity and thickness.RESULTS:The signal hypointensity-to-thickness ratio of the primary motor cortex was greater in patients than in controls (P < .001), and it correlated with upper motor neuron impairment in patients (ρ = 0.57, P < .001). The diagnostic accuracy of the signal hypointensity-to-thickness ratio was high at 3T (area under the curve = 0.89) and even higher at 7T (area under the curve = 0.94). The sensitivity of the semiautomated method (0.81) outperformed the sensitivity of the visual assessment (0.56–0.63) at 3T.CONCLUSIONS:The signal hypointensity-to-thickness ratio of the primary motor cortex calculated with a semiautomated method is suggested as a radiologic marker of upper motor neuron burden in patients with amyotrophic lateral sclerosis. This semiautomated method may be useful for improving the subjective radiologic evaluation of upper motor neuron pathology in patients suspected of having amyotrophic lateral sclerosis.
Endoscopic therapy of brisk upper gastrointestinal bleeding remains challenging. A proprietary nanopowder (TC-325) has been proven to be effective in high pressure bleeding from external wounds. The ...efficacy and safety of TC-325 were assessed in a survival gastrointestinal bleeding animal model.
10 animals were randomized to treatment or sham. All animals received intravenous antibiotics, H2-blockers and heparin (activated clotting time 2 × normal). In a sterile laparotomy the gastroepiploic vessels were dissected, inserted through a 1-cm gastrotomy, and freely exposed in the gastric lumen, and the exposed vessel lacerated by needle knife. The treatment group received TC-325 by a modified delivery catheter while the sham group received no endoscopic treatment. Time to hemostasis, and mortality at 60 minutes, 24 hours, 48 hours, and 7 days were noted. Necropsy was performed in all animals.
Spurting arterial bleeding was achieved in all animals. No control animal showed hemostasis within the first hour compared with 100 % (5 / 5) in the treatment arm (mean 13.8 minutes, P < 0.0079). Durable hemostasis was achieved with no evidence of rebleeding after 1 and 24 hours in 80 % (4 / 5) of the treated animals compared with none in the control group ( P < 0.0098). None of the control animals survived more than 6 hours. Necropsy at 1 week in treated animals revealed healed gastrotomy without foreign body granuloma or embolization to the lung or brain.
TC-325 is safe and highly effective in achieving hemostasis in an anticoagulated severe arterial gastrointestinal bleeding animal model.
Computed tomography for dimensional metrology has been introduced in quality control loop for about a decade. Due to the complex measurement-error cause system, generally no consistent measurement ...uncertainty reporting has been made. The ISO 15530-3 experimental approach, which makes use of calibrated parts, has been tested for estimating the uncertainty of CT-based measurements of features of size of a test object made of POM. Particular attention is given to the design of experiment and to the measurement uncertainty components. The most significant experimental findings are outlined and discussed in this paper.
In recent years, computed tomography (CT) has been applied as an industrial metrology tool for the dimensional evaluation of visible and even hidden features of production parts in a non-destructive ...manner. Considering the experimental findings of a recent work of the authors, this paper deals with the effect of voxel size on measuring distances between feature-of-size centers, which would be less sensitive to edge offset errors. Particular attention is given to the design of experiment and to the measurement uncertainty sources. The most significant experimental findings are outlined and discussed in this paper.