Aerosol-generating procedures are medical interventions considered high risk for transmission of airborne pathogens. Tracheal intubation of anaesthetised patients is not high risk for aerosol ...generation; however, patients often perform respiratory manoeuvres during awake tracheal intubation which may generate aerosol. To assess the risk, we undertook aerosol monitoring during a series of awake tracheal intubations and nasendoscopies in healthy participants. Sampling was undertaken within an ultraclean operating theatre. Procedures were performed and received by 12 anaesthetic trainees. The upper airway was topically anaesthetised with lidocaine and participants were not sedated. An optical particle sizer continuously sampled aerosol. Passage of the bronchoscope through the vocal cords generated similar peak median (IQR range) aerosol concentrations to coughing, 1020 (645-1245 120-48,948) vs. 1460 (390-2506 40-12,280) particles.l
respectively, p = 0.266. Coughs evoked when lidocaine was sprayed on the vocal cords generated 91,700 (41,907-166,774 390-557,817) particles.l
which was significantly greater than volitional coughs (p < 0.001). For 38 nasendoscopies in 12 participants, the aerosol concentrations were relatively low, 180 (120-525 0-9552) particles.l
, however, five nasendoscopies generated peak aerosol concentrations greater than a volitional cough. Awake tracheal intubation and nasendoscopy can generate high concentrations of respiratory aerosol. Specific risks are associated with lidocaine spray of the larynx, instrumentation of the vocal cords, procedural coughing and deep breaths. Given the proximity of practitioners to patient-generated aerosol, airborne infection control precautions are appropriate when undertaking awake upper airway endoscopy (including awake tracheal intubation, nasendoscopy and bronchoscopy) if respirable pathogens cannot be confidently excluded.
Emergency abdominal surgery is associated with a high risk of postoperative pulmonary complications (PPCs). The primary aim of this study was to determine whether patients undergoing emergency ...laparotomy are ventilated using a lung-protective ventilation strategy employing tidal volume ≤8 ml kg−1 ideal body weight−1, PEEP >5 cm H2O, and recruitment manoeuvres. The secondary aim was to investigate the association between ventilation factors (lung-protective ventilation strategy, intraoperative FiO2, and peak inspiratory pressure) and the occurrence of PPCs.
Data were collected prospectively in 28 hospitals across London as part of routine National Emergency Laparotomy Audit (NELA). Patients were followed for 7 days. Complications were defined according to the European Perioperative Clinical Outcome definition.
Data were collected from 568 patients. The median inter-quartile range (IQR) tidal volume observed was 500 ml (450–540 ml), corresponding to a median tidal volume of 8 ml kg−1 ideal body weight−1 (IQR: 7.2–9.1 ml). A lung-protective ventilation strategy was employed in 4.9% (28/568) of patients, and was not protective against the occurrence of PPCs in the multivariable analysis (hazard ratio=1.06; P=0.69). Peak inspiratory pressure of <30 cm H2O was protective against development of PPCs (hazard ratio=0.46; confidence interval: 0.30–0.72; P=0.001). Median FiO2 was 0.5 (IQR: 0.44–0.53), and an increase in FiO2 by 5% increased the risk of developing a PPC by 8% (2.6–14.1%; P=0.008).
Both intraoperative peak inspiratory pressure and FiO2 are independent factors significantly associated with development of a postoperative pulmonary complication in emergency laparotomy patients. Further studies are required to identify causality and to demonstrate if their manipulation could lead to better clinical outcomes.