Workshop summary: Kaons@CERN 2023 Anzivino, G.; Cuendis, Sergio Arguedas; Bernard, V. ...
European physical journal. C, Particles and fields,
04/2024, Letnik:
84, Številka:
4
Journal Article
Recenzirano
Odprti dostop
Kaon physics is at a turning point – while the rare-kaon experiments NA62 and KOTO are in full swing, the end of their lifetime is approaching and the future experimental landscape needs to be ...defined. With HIKE, KOTO-II and LHCb-Phase-II on the table and under scrutiny, it is a very good moment in time to take stock and contemplate about the opportunities these experiments and theoretical developments provide for particle physics in the coming decade and beyond. This paper provides a compact summary of talks and discussions from the Kaons@CERN 2023 workshop, held in September 2023 at CERN.
NA62 RICH performance: measurement and optimization Anzivino, G.; Barbanera, M.; Bizzeti, A. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
02/2020, Letnik:
952
Journal Article
Recenzirano
Odprti dostop
The Ring Imaging Cherenkov detector of the NA62 experiment at CERN SPS was commissioned in 2014, but the optimal performance was achieved in 2016 after the precise mirror alignment with reconstructed ...tracks. The measurement and monitoring of basic performance parameters is discussed: ring radius resolution, ring centre resolution, single hit resolution and mean number of hits per ring. The performance is measured with 2016 data on the positron sample. Different contributions to the resolutions are calculated.
The role of the NA62 RICH in the BR(K+→π+νν̄) measurement Volpe, R.; Anzivino, G.; Aisa, D. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
02/2020, Letnik:
952
Journal Article
Recenzirano
The NA62 experiment aims to measure the BR(K+→π+νν̄) with a 10% precision. One of the main backgrounds comes from the decay K+→μ+ν, therefore a highly powerful pion/muon separation is needed. The ...NA62 RICH, together with the calorimeter system, provides an accurate particle identification which has been essential to obtain the first results of the NA62 K+→π+νν̄ analysis, based on 2016 data. Two different algorithms have been exploited which, used in combination, allowed to get a pion reconstruction and identification efficiency of 75%, with a muon suppression factor of about 500, in the momentum range 15–35 GeV/c.
Status of the NA62 ring imaging Cherenkov detector Cenci, P.; Anzivino, G.; Aisa, D. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
02/2020, Letnik:
952
Journal Article
Recenzirano
The Ring Imaging Cherenkov detector of the NA62 experiment at the CERN SPS is a key element of particle identification in the NA62 experimental strategy. The detector fulfills different conditions: ...to distinguish pions from muons with a muon rejection factor of O(102) in the NA62 momentum range of operation, between 15 and 35 GeV/c; to measure particle arrival time in the decay region with a precision better than 100 ps; to provide fast signals and reference time to the NA62 trigger system. The main design aspects and functional characteristics, as well as the performance of the detector measured with the data taken in the first NA62 physics runs, will be summarized in this paper.
•The NA62 experiment aims to measure the branching ratio of the K+→π+νν¯ decay.•The NA62 RICH performance fulfills the experiment requirements.•Pion–muon identification is performed with a muon rejection factor of O(102).•Time resolution with precision better than 100 ps is achieved.•The RICH is a key element to select charged particles in the trigger system.
Particle identification with the NA62 RICH detector Duk, V.; Anzivino, G.; Bizzeti, A. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
December 2023, 2023-12-00, Letnik:
1057
Journal Article
Recenzirano
NA62 is a new generation kaon experiment at the CERN SPS aiming at studying rare and forbidden decays. One of main challenges of the experiment is the suppression of background decay channels with ...branching ratios up to 10 orders of magnitude higher than the signal and with similar experimental signatures. To provide such suppression, a powerful particle identification (PID) is needed.
A key element of PID in NA62 is the Ring Imaging Cherenkov (RICH) detector. The RICH has successfully operated during the 2016–2018 data taking periods, being essential in the measurement of the branching ratio of the K+→π+νν̄ decay. The detector was also used for searches for lepton number violation in 3-track kaon decays. The results on the π/μ and π/e separation directly measured with the data for the aforementioned decays are presented.
Ronchi test for flat mirrors Estrada, N.; Engelfried, J.; Morelos, A.
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
11/2005, Letnik:
553, Številka:
1
Journal Article
Recenzirano
One of the RICHes in the velocity spectrometers of the proposed CKM experiment requires a flat mirror, situated in the high intensity kaon beam. To reduce the interaction background for the ...experiment, this mirror has to be as thin as possible. First glass prototypes were produced in Mexico. To test the surface quality of these prototypes, we extended the Ronchi method so flat mirrors can also be tested. We present the methods and report on results of our measurements.
A precision measurement of the ratio RK of the rates of kaon leptonic decays K±→e±ν and K±→μ±ν with the full data sample collected by the NA62 experiment at CERN in 2007–2008 is reported. The result, ...obtained by analysing ∼150000 reconstructed K±→e±ν candidates with 11% background contamination, is RK=(2.488±0.010)×10−5, in agreement with the Standard Model expectation.
Search of the Exotic State U(3100) in SELEX Blanco-Covarrubias, A; Engelfried, J; collaboration, the SELEX
Journal of physics. Conference series,
05/2006, Letnik:
37, Številka:
1
Journal Article
Recenzirano
Odprti dostop
Using data from the SELEX Experiment (Fermilab E781)1 we searched for a previously reported exotic state at 3.100GeV/c2 decaying into Λ0 + nπ±, (n 1, 2, 3). No signal in any of the different charge ...modes is observed.