We present the achievements of the last years of the experimental and theoretical groups working on hadronic cross section measurements at the low-energy
e
+
e
−
colliders in Beijing, Frascati, ...Ithaca, Novosibirsk, Stanford and Tsukuba and on
τ
decays. We sketch the prospects in these fields for the years to come. We emphasise the status and the precision of the Monte Carlo generators used to analyse the hadronic cross section measurements obtained as well with energy scans as with radiative return, to determine luminosities and
τ
decays. The radiative corrections fully or approximately implemented in the various codes and the contribution of the vacuum polarisation are discussed.
The anomalous magnetic moment of the negative muon has been measured to a precision of 0.7 ppm (ppm) at the Brookhaven Alternating Gradient Synchrotron. This result is based on data collected in ...2001, and is over an order of magnitude more precise than the previous measurement for the negative muon. The result a(mu(-))=11 659 214(8)(3) x 10(-10) (0.7 ppm), where the first uncertainty is statistical and the second is systematic, is consistent with previous measurements of the anomaly for the positive and the negative muon. The average of the measurements of the muon anomaly is a(mu)(exp)=11 659 208(6) x 10(-10) (0.5 ppm).
The cross section of the process e + e − → π + π − has been measured in the center-of-mass energy range from 0.32 to 1.2 GeV with the CMD-3 detector at the electron-positron collider VEPP-2000. The ...measurement is based on an integrated luminosity of about 88 pb − 1 , of which 62 pb − 1 represent a complete dataset collected by CMD-3 at center-of-mass energies below 1 GeV. In the dominant region near the ρ resonance a systematic uncertainty of 0.7% was achieved. The implications of the presented results for the evaluation of the hadronic contribution to the anomalous magnetic moment of the muon are discussed. Published by the American Physical Society 2024
A preliminary result of an analysis of the process
whose cross section was measured in the range of center-of-mass collision energies between 1.2 and 2 GeV is presented. The analysis is based on the ...data sample corresponding to an integrated luminosity of about 120 pb
accumulated with the CMD-3 detector at the VEPP-2000 electron–positron collider. A procedure for separating signal events is developed, and the dominance of the
neutral mode is confirmed. The cross section for the process
is measured to a precision higher than that in earlier experiments. This permits improving the accuracy in measuring the mass and width of the
(1680) meson, testing the accuracy of the isotopic relations, and more accurately calculating the hadronic contribution to the muon anomalous magnetic moment (
).
A higher precision measurement of the anomalous g value, a(mu)=(g-2)/2, for the positive muon has been made at the Brookhaven Alternating Gradient Synchrotron, based on data collected in the year ...2000. The result a(mu(+))=11 659 204(7)(5)x10(-10) (0.7 ppm) is in good agreement with previous measurements and has an error about one-half that of the combined previous data. The present world average experimental value is a(mu)(expt)=11 659 203(8)x10(-10) (0.7 ppm).
A precise measurement of the anomalous g value, a(mu) = (g-2)/2, for the positive muon has been made at the Brookhaven Alternating Gradient Synchrotron. The result a(mu+) = 11 659 202(14) (6) x ...10(-10) (1.3 ppm) is in good agreement with previous measurements and has an error one third that of the combined previous data. The current theoretical value from the standard model is a(mu)(SM) = 11 659 159.6(6.7) x 10(-10) (0.57 ppm) and a(mu)(exp) - a(mu)(SM) = 43(16) x 10(-10) in which a(mu)(exp) is the world average experimental value.
Overview of the CMD-3 recent results Ryzhenenkov, A E; Akhmetshin, R R; Amirkhanov, A N ...
Journal of physics. Conference series,
04/2020, Letnik:
1526, Številka:
1
Journal Article
Recenzirano
Odprti dostop
The CMD-3 detector started data taking at the electron-positron collider VEPP-2000 in December 2010 with a goal to collect about 1 fb−1. The collected data sample corresponds to an integrated ...luminosity of 200 pb−1 in the center-of-mass energy range from 0.32 up to 2 GeV. This paper reports recent results on the hadronic cross sections measurements with the CMD-3 detector.
COMET Phase-I technical design report Abramishvili, R; Adamov, G; Allin, A ...
Progress of theoretical and experimental physics,
03/2020, Letnik:
2020, Številka:
3
Journal Article
Recenzirano
Odprti dostop
Abstract
The Technical Design for the COMET Phase-I experiment is presented in this paper. COMET is an experiment at J-PARC, Japan, which will search for neutrinoless conversion of muons into ...electrons in the field of an aluminum nucleus ($\mu$–$e$ conversion, $\mu^{-}N \rightarrow e^{-}N$); a lepton flavor-violating process. The experimental sensitivity goal for this process in the Phase-I experiment is $3.1\times10^{-15}$, or 90% upper limit of a branching ratio of $7\times 10^{-15}$, which is a factor of 100 improvement over the existing limit. The expected number of background events is 0.032. To achieve the target sensitivity and background level, the 3.2 kW 8 GeV proton beam from J-PARC will be used. Two types of detectors, CyDet and StrECAL, will be used for detecting the $\mu$–$e$ conversion events, and for measuring the beam-related background events in view of the Phase-II experiment, respectively. Results from simulation on signal and background estimations are also described.
Recent results from CMD-3 Ignatov, F. V.; Akhmetshin, R. R.; Amirkhanov, A. N. ...
EPJ Web of Conferences,
2019, Letnik:
212
Journal Article, Conference Proceeding
Recenzirano
Odprti dostop
Regular data taking with the CMD-3 at the electron-positron collider VEPP-2000 is under way since 2010. The collected data sample corresponds to about 200 inverse picobarns of integrated luminosity ...per detector in the energy range from 0.32 up to 2 GeV, with a goal to collect about 1
fb
−1
during next five years. Some of the recent results from the CMD-3 detector are discussed.