Abstract
Aims
Severe tricuspid regurgitation (TR) has adverse effects on outcomes, with limited therapeutic options. We report the outcomes of patients undergoing percutaneous annuloplasty as a ...treatment of ≥severe functional TR in a single centre.
Methods and results
Prospective, single-arm, single-centre study that enrolled 24 consecutive patients with at least severe functional TR undergoing percutaneous annuloplasty with Cardioband system between 2019 and 2021. Clinical and echocardiographic data were prospectively collected, with a mean follow-up of 279 ± 246 days. At baseline, 66.6% were in New York Heart Association (NYHA) Classes III and IV and 100% had significant oedema. Technical success was 91.6%. At the end of follow-up, there was one death. Echocardiography showed a significant reduction in septolateral annular diameter of 10.4 mm (P < 0.001) that remained stable at the end of follow-up. The severity of the TR was also reduced. About 81.8% of patients were in NYHA Classes I and II. The number of patients with significant oedema decreased to 46% (P = 0.01). Six-minute walk distance improved by 68.8 m (P = 0.12).
Conclusion
Percutaneous annuloplasty with Cardioband system is an effective and safe treatment for patients with symptomatic, ≥severe functional TR. Annular reduction and TR severity reduction remained significant and sustained for 1 year. Patients experienced improvements in quality of life and exercise capacity.
Graphical Abstract
Graphical Abstract
Effects of Cardioband implantation for the treatment of tricuspid regurgitation. TR, tricuspid regurgitation; NYHA, New York Heart Association; SVC, superior vein cava; IVC, inferior vein cava; IAS, interatrial septum.
Pseudoaneurysm after TAVR: how to close the hole? Salido Tahoces, Luisa; Fernández-Golfín, Covadonga; Pardo Sanz, Ana ...
European heart journal cardiovascular imaging,
05/2023, Letnik:
24, Številka:
6
Journal Article
The optimal duration of anticoagulation in patients with left-ventricular thrombus (LVT) is unclear. In the present study, we aimed to analyze the effect of treatment duration (≤12 months short-term ...anticoagulation, (STA) versus >12 months long-term anticoagulation, (LTA)) in the incidence of stroke and other secondary outcomes (acute myocardial infarction, bleeding, and mortality). Multivariate Cox regression was used to determine the association between treatment duration and stroke, adjusted for baseline embolic risk. A total of 98 cases of LVT (age 64.3 ± 12.8 years, female 18 18%) were identified. Sixty-one patients (62%) received LTA. Patients receiving LTA were older than those receiving STA (66.5 ± 11.6 vs 60.7 ± 13.9 years, p = 0.029), more often had atrial fibrillation (31% vs 0%, p <0.001), and had a higher CHA2DS2-VASc score (4.3 ± 1.6 vs 3.6 ± 1.6, p = 0.046). Stroke occurred in 2 and 10 patients (3% vs 27%, p <0.001), acute myocardial infarction in 2 and 3 patients (3% vs 8%, p = 0.292), bleeding in 4 and 3 patients (7% vs 8%, p = 0.773), and mortality in 12 and 7 patients (20% vs 19%, p = 0.927) in the LTA and STA groups, respectively. In multivariate analysis, after adjusting for embolic risk, LTA was associated with decreased risk of stroke at 5 years (adjusted hazard ratio 0.16; 95% confidence interval 0.03 to 0.72, p = 0.017). In conclusion, our data suggest that prolonged anticoagulation in patients with LVT may be associated with significantly lower risk of stroke.
Left ventricular systolic function evaluation is an essential part of all transthoracic echocardiographic (TTE) studies. 3D echocardiography (3DE) is superior to 2D and is recommended as the method ...of choice. However, since it is time consuming and requires training, it is rarely performed. Different automatic analysis software tries to overcome these limitations but they need to be accurate and reproducible before they can be used clinically. The aim of this study was to test the accuracy and reproducibility of new 3D automatic quantitative software in everyday clinical practice. 69 patients referred to our Echo Lab for a clinically indicated echocardiographic examination were included. All patients underwent a full TTE with 3D image acquisition. Left ventricular volumes and ejection fraction (LVEF) were obtained using Heart Model software, and compared with conventional 3D volumetric data. Automated analysis was performed using three different sliders setting, with or without regional editing if necessary. 20 patients underwent a cardiac magnetic resonance (CMR) study the same day of the echo and automated measurements were also compared with a CMR reference. Intra- and inter-technique comparisons including linear regression with Pearson correlation coefficients and Bland–Altman analyses were calculated. Mean age of the patients was 59 years, with 49.3% male. The automated 3DE model demonstrated excellent correlation with the conventional 3DE measurements of LVEF, using three different sliders settings (r = 0.906; r = 0.898 and r = 0.940). Correlations with CMR values were very good as well (r = 0.888; r = 0.869; r = 0.913). Similarly, no significant differences were noted between the values of EDV and ESV, measured with the automated model or CMR, with excellent correlation (EDV: r = 0.892, r = 0.842, 0.910; ESV: r = 0.925, r = 0.860, r = 0.907). Finally, volumes calculated with the automated software were significantly greater than those obtained manually, but they showed a very good correlation (EDV: r = 0.875, r = 0.856, r = 0.891; ESV: r = 0.929, r = 0.879, r = 949). 3D automatic software for LV quantification is feasible and shows excellent correlations with both CMR and 3D echocardiography, considered the gold standard. No clinically relevant differences were noted when applying different border settings. This technique holds promise to facilitate the integration of 3D TTE into clinical practice.
The optimal duration of anticoagulation in patients with left ventricular thrombus (LVT) is unknown. The data package herein presented contains the information used to assess the effect of duration ...of anticoagulation in the incidence of stroke in patients with left ventricular thrombus (LVT) in a tertiary hospital. In order to collect the required data, all transthoracic echocardiography studies at our institution from January 1st 2014 to December 31st 2021 with LVT were retrieved using dedicated software (Phillips Intellispace Cardiovascular; Koninklijke Phillips N.V., 2004-2020). Second, a dataset was designed ad hoc for this study in which the recruited data for the predefined objectives were obtained from electronic medical records. These data included clinical and demographic information including treatment choices (vitamin K antagonists VKA versus direct oral anticoagulants DOAC), duration of treatment, reason for interruption of treatment, occurrence of stroke, acute myocardial infarction, bleeding events, thrombus resolution, recurrence, and death. Retrieved data were stored in an excel sheet for analysis using the statistical package STATA (StataCorp v. 15.0, College station, TX). This methodology allows the reuse of these data for further analysis, in the context of the present study and also for future recruitment of additional patients from other institutions to increase statistical power.