Objectives The aim of this study was to compare the reproducibility of 7 late gadolinium enhancement (LGE) quantification techniques across 3 conditions in which LGE is known to be important: acute ...myocardial infarction (AMI), chronic myocardial infarction (CMI), and hypertrophic cardiomyopathy (HCM). Background LGE by cardiac magnetic resonance is the gold-standard technique for assessing myocardial scar. No consensus exists on the best method for its quantification, and research in this area is scant. Techniques include manual quantification, thresholding by 2, 3, 4, 5, or 6 SDs above remote myocardium, and the full width at half maximum (FWHM) technique. To date, LGE has been linked to outcome in 3 conditions: AMI, CMI, and HCM. Methods Sixty patients with 3 LGE etiologies (AMI, n = 20; CMI, n = 20; HCM, n = 20) were scanned for LGE. LGE volume was quantified using the 7 techniques. Mean LGE volume, interobserver and intraobserver reproducibility, and impact on sample size were assessed. Results LGE volume varied significantly with the quantification method used. There was no statistically significant difference between LGE volume by the FWHM, manual, and 6-SD or 5-SD techniques. The 2-SD technique generated LGE volumes up to 2 times higher than the FWHM, 6-SD, and manual techniques. The reproducibility of all techniques was worse in HCM than AMI or CMI. The FWHM technique was the most reproducible in all 3 conditions compared with any other method (p < 0.001). Use of the FWHM technique for LGE quantification in paired analysis would lead to at least a 60% reduction in required sample size compared with any other method. Conclusions Regardless of the disease under study, the FWHM technique for LGE quantification gives LGE volume mean results similar to manual quantification and is statistically the most reproducible, reducing required sample sizes by up to one-half.
Myocardial extracellular volume (ECV) is elevated in fibrosis or infiltration and can be quantified by measuring the haematocrit with pre and post contrast T1 at sufficient contrast equilibrium. ...Equilibrium CMR (EQ-CMR), using a bolus-infusion protocol, has been shown to provide robust measurements of ECV using a multibreath-hold T1 pulse sequence. Newer, faster sequences for T1 mapping promise whole heart coverage and improved clinical utility, but have not been validated.
Multibreathhold T1 quantification with heart rate correction and single breath-hold T1 mapping using Shortened Modified Look-Locker Inversion recovery (ShMOLLI) were used in equilibrium contrast CMR to generate ECV values and compared in 3 ways.Firstly, both techniques were compared in a spectrum of disease with variable ECV expansion (n=100, 50 healthy volunteers, 12 patients with hypertrophic cardiomyopathy, 18 with severe aortic stenosis, 20 with amyloid). Secondly, both techniques were correlated to human histological collagen volume fraction (CVF%, n=18, severe aortic stenosis biopsies). Thirdly, an assessment of test:retest reproducibility of the 2 CMR techniques was performed 1 week apart in individuals with widely different ECVs (n=10 healthy volunteers, n=7 amyloid patients).
More patients were able to perform ShMOLLI than the multibreath-hold technique (6% unable to breath-hold). ECV calculated by multibreath-hold T1 and ShMOLLI showed strong correlation (r(2)=0.892), little bias (bias -2.2%, 95%CI -8.9% to 4.6%) and good agreement (ICC 0.922, range 0.802 to 0.961, p<0.0001). ECV correlated with histological CVF% by multibreath-hold ECV (r(2)= 0.589) but better by ShMOLLI ECV (r(2)= 0.685). Inter-study reproducibility demonstrated that ShMOLLI ECV trended towards greater reproducibility than the multibreath-hold ECV, although this did not reach statistical significance (95%CI -4.9% to 5.4% versus 95%CI -6.4% to 7.3% respectively, p=0.21).
ECV quantification by single breath-hold ShMOLLI T1 mapping can measure ECV by EQ-CMR across the spectrum of interstitial expansion. It is procedurally better tolerated, slightly more reproducible and better correlates with histology compared to the older multibreath-hold FLASH techniques.
To develop and validate equilibrium contrast material-enhanced computed tomography (CT) to measure myocardial extracellular volume (ECV) fraction by using a histologic reference standard and to ...compare equilibrium CT with equilibrium contrast-enhanced magnetic resonance (MR) imaging.
A local ethics committee approved the study, and all subjects gave fully informed written consent. An equilibrium CT protocol was developed using iohexol at 300 mg of iodine per milliliter (bolus of 1 mg per kilogram of body weight administered at a rate of 3 mL/sec, followed immediately by an infusion of 1.88 mL/kg per hour with CT imaging before and at 25 minutes after injection of bolus of contrast agent) and ECV within the myocardial septum measured using both equilibrium CT and equilibrium MR imaging in patients with severe aortic stenosis. Biopsy samples of the myocardial septum collected during valve replacement surgery were used for histologic quantification of extracellular fibrosis with picrosirius red staining. Equilibrium CT- and equilibrium MR imaging-derived ECV measurements were compared with histologically quantified fibrosis by using Pearson correlation. Agreement between equilibrium CT and equilibrium MR imaging was assessed by using Bland-Altman comparison.
Twenty-three patients (16 male, seven female; mean age, 70.8 years; standard deviation, 8.3) were recruited. The mean percentage of histologic fibrosis was 18% (intersubject range, 5%-40%). There was a significant correlation between both equilibrium CT- and equilibrium MR imaging-derived ECV and percentage of histologic fibrosis (r = 0.71 P < .001 and r = 0.84 P < .0001, respectively). Equilibrium CT-derived ECV was significantly correlated to equilibrium MR imaging-derived ECV (r = 0.73).
ECV measured by using equilibrium CT in patients with aortic stenosis correlates with histologic quantification of myocardial fibrosis and with ECV derived by using equilibrium MR imaging.
Anderson-Fabry disease (AFD) is a rare but underdiagnosed intracellular lipid disorder that can cause left ventricular hypertrophy (LVH). Lipid is known to shorten the magnetic resonance imaging ...parameter T1. We hypothesized that noncontrast T1 mapping by cardiovascular magnetic resonance would provide a novel and useful measure in this disease with potential to detect early cardiac involvement and distinguish AFD LVH from other causes.
Two hundred twenty-seven subjects were studied: patients with AFD (n=44; 55% with LVH), healthy volunteers (n=67; 0% with LVH), patients with hypertension (n=41; 24% with LVH), patients with hypertrophic cardiomyopathy (n=34; 100% with LVH), those with severe aortic stenosis (n=21; 81% with LVH), and patients with definite amyloid light-chain (AL) cardiac amyloidosis (n=20; 100% with LVH). T1 mapping was performed using the shortened modified Look-Locker inversion sequence on a 1.5-T magnet before gadolinium administration with primary results derived from the basal and midseptum. Compared with health volunteers, septal T1 was lower in AFD and higher in other diseases (AFD versus healthy volunteers versus other patients, 882±47, 968±32, 1018±74 milliseconds; P<0.0001). In patients with LVH (n=105), T1 discriminated completely between AFD and other diseases with no overlap. In AFD, T1 correlated inversely with wall thickness (r=-0.51; P=0.0004) and was abnormal in 40% of subjects who did not have LVH. Segmentally, AFD showed pseudonormalization or elevation of T1 in the left ventricular inferolateral wall, correlating with the presence or absence of late gadolinium enhancement (1001±82 versus 891±38 milliseconds; P<0.0001).
Noncontrast T1 mapping shows potential as a unique and powerful measurement in the imaging assessment of LVH and AFD.
Extracellular matrix expansion is a key element of ventricular remodeling and a potential therapeutic target. Cardiovascular magnetic resonance (CMR) T1-mapping techniques are increasingly used to ...evaluate myocardial extracellular volume (ECV); however, the most widely applied methods are without histological validation. Our aim was to perform comprehensive validation of (1) dynamic-equilibrium CMR (DynEq-CMR), where ECV is quantified using hematocrit-adjusted myocardial and blood T1 values measured before and after gadolinium bolus; and (2) isolated measurement of myocardial T1, used as an ECV surrogate.
Whole-heart histological validation was performed using 96 tissue samples, analyzed for picrosirius red collagen volume fraction, obtained from each of 16 segments of the explanted hearts of 6 patients undergoing heart transplantation who had prospectively undergone CMR before transplantation (median interval between CMR and transplantation, 29 days). DynEq-CMR-derived ECV was calculated from T1 measurements made using a modified Look-Locker inversion recovery sequence before and 10 and 15 minutes post contrast. In addition, ECV was measured 2 to 20 minutes post contrast in 30 healthy volunteers. There was a strong linear relationship between DynEq-CMR-derived ECV and histological collagen volume fraction (P<0.001; within-subject: r=0.745; P<0.001; r(2)=0.555 and between-subject: r=0.945; P<0.01; r(2)=0.893; for ECV calculated using 15-minute postcontrast T1). Correlation was maintained throughout the entire heart. Isolated postcontrast T1 measurement showed significant within-subject correlation with histological collagen volume fraction (r=-0.741; P<0.001; r(2)=0.550 for 15-minute postcontrast T1), but between-subject correlations were not significant. DynEq-CMR-derived ECV varied significantly according to contrast dose, myocardial region, and sex.
DynEq-CMR-derived ECV shows a good correlation with histological collagen volume fraction throughout the whole heart. Isolated postcontrast T1 measurement is insufficient for ECV assessment.
Abstract Objectives This study aimed to determine whether remote ischemic conditioning (RIC) initiated prior to primary percutaneous coronary intervention (PPCI) could reduce myocardial infarct (MI) ...size in patients presenting with ST-segment elevation myocardial infarction. Background RIC, using transient limb ischemia and reperfusion, can protect the heart against acute ischemia-reperfusion injury. Whether RIC can reduce MI size, assessed by cardiac magnetic resonance (CMR), is unknown. Methods We randomly assigned 197 ST-segment elevation myocardial infarction patients with TIMI (Thrombolysis In Myocardial Infarction) flow grade 0 to receive RIC (four 5-min cycles of upper arm cuff inflation/deflation) or control (uninflated cuff placed on upper arm for 40 min) protocols prior to PPCI. The primary study endpoint was MI size, measured by CMR in 83 subjects on days 3 to 6 after admission. Results RIC reduced MI size by 27%, when compared with the MI size of control subjects (18.0 ± 10% n = 40 vs. 24.5 ± 12.0% n = 43; p = 0.009). At 24 h, high-sensitivity troponin T was lower with RIC (2,296 ± 263 ng/l n = 89 vs. 2,736 ± 325 ng/l n = 84; p = 0.037). RIC also reduced the extent of myocardial edema measured by T2 -mapping CMR (28.5 ± 9.0% vs. 35.1 ± 10.0%; p = 0.003) and lowered mean T2 values (68.7 ± 5.8 ms vs. 73.1 ± 6.1 ms; p = 0.001), precluding the use of CMR edema imaging to correctly estimate the area at risk. Using CMR-independent coronary angiography jeopardy scores to estimate the area at risk, RIC, when compared with the control protocol, was found to significantly improve the myocardial salvage index (0.42 ± 0.29 vs. 0.28 ± 0.29; p = 0.03). Conclusions This randomized study demonstrated that in ST-segment elevation myocardial infarction patients treated by PPCI, RIC, initiated prior to PPCI, reduced MI size, increased myocardial salvage, and reduced myocardial edema.
Diffuse myocardial fibrosis is a final end point in most cardiac diseases. It is missed by the cardiovascular magnetic resonance (CMR) late gadolinium enhancement technique. Currently, quantifying ...diffuse myocardial fibrosis requires invasive biopsy, with inherent risk and sampling error. We have developed a robust and noninvasive technique, equilibrium contrast CMR (EQ-CMR) to quantify diffuse fibrosis and have validated it against the current gold standard of surgical myocardial biopsy.
The 3 principles of EQ-CMR are a bolus of extracellular gadolinium contrast followed by continuous infusion to achieve equilibrium; a blood sample to measure blood volume of distribution (1-hematocrit); and CMR to measure pre- and postequilibrium T1 (with heart rate correction). The myocardial volume of distribution is calculated, reflecting diffuse myocardial fibrosis. Clinical validation occurred in patients undergoing aortic valve replacement for aortic stenosis or myectomy in hypertrophic cardiomyopathy (n=18 and n=8, respectively). Surgical biopsies were analyzed for picrosirius red fibrosis quantification on histology. The mean histological fibrosis was 20.5+/-11% in aortic stenosis and 17.1+/-7.4% in hypertrophic cardiomyopathy. EQ-CMR correlated strongly with biopsy histological fibrosis: aortic stenosis, r(2)=0.86, Kendall Tau coefficient (T)=0.71, P<0.001; hypertrophic cardiomyopathy, r(2)=0.62, T=0.52, P=0.08; combined r(2)=0.80, T=0.67, P<0.001.
We have developed and validated a new technique, EQ-CMR, to measure diffuse myocardial fibrosis as an add-on to a standard CMR scan, which allows for the noninvasive quantification of the diffuse fibrosis burden in myocardial diseases.
Left ventricular noncompaction (LVNC) is a myocardial disorder characterized by excessive left ventricular (LV) trabeculae. Current methods for quantification of LV trabeculae have limitations. The ...aim of this study is to describe a novel technique for quantifying LV trabeculation using cardiovascular magnetic resonance (CMR) and fractal geometry. Observing that trabeculae appear complex and irregular, we hypothesize that measuring the fractal dimension (FD) of the endocardial border provides a quantitative parameter that can be used to distinguish normal from abnormal trabecular patterns.
Fractal analysis is a method of quantifying complex geometric patterns in biological structures. The resulting FD is a unitless measure index of how completely the object fills space. FD increases with increased structural complexity. LV FD was measured using a box-counting method on CMR short-axis cine stacks. Three groups were studied: LVNC (defined by Jenni criteria), n=30(age 41±13; men, 16); healthy whites, n=75(age, 46±16; men, 36); healthy blacks, n=30(age, 40±11; men, 15).
In healthy volunteers FD varied in a characteristic pattern from base to apex along the LV. This pattern was altered in LVNC where apical FD were abnormally elevated. In healthy volunteers, blacks had higher FD than whites in the apical third of the LV (maximal apical FD: 1.253±0.005 vs. 1.235±0.004, p<0.01) (mean±s.e.m.). Comparing LVNC with healthy volunteers, maximal apical FD was higher in LVNC (1.392±0.010, p<0.00001). The fractal method was more accurate and reproducible (ICC, 0.97 and 0.96 for intra and inter-observer readings) than two other CMR criteria for LVNC (Petersen and Jacquier).
FD is higher in LVNC patients compared to healthy volunteers and is higher in healthy blacks than in whites. Fractal analysis provides a quantitative measure of trabeculation and has high reproducibility and accuracy for LVNC diagnosis when compared to current CMR criteria.