Closed-loop systems that automate insulin delivery may improve glycemic outcomes in patients with type 1 diabetes.
In this 6-month randomized, multicenter trial, patients with type 1 diabetes were ...assigned in a 2:1 ratio to receive treatment with a closed-loop system (closed-loop group) or a sensor-augmented pump (control group). The primary outcome was the percentage of time that the blood glucose level was within the target range of 70 to 180 mg per deciliter (3.9 to 10.0 mmol per liter), as measured by continuous glucose monitoring.
A total of 168 patients underwent randomization; 112 were assigned to the closed-loop group, and 56 were assigned to the control group. The age range of the patients was 14 to 71 years, and the glycated hemoglobin level ranged from 5.4 to 10.6%. All 168 patients completed the trial. The mean (±SD) percentage of time that the glucose level was within the target range increased in the closed-loop group from 61±17% at baseline to 71±12% during the 6 months and remained unchanged at 59±14% in the control group (mean adjusted difference, 11 percentage points; 95% confidence interval CI, 9 to 14; P<0.001). The results with regard to the main secondary outcomes (percentage of time that the glucose level was >180 mg per deciliter, mean glucose level, glycated hemoglobin level, and percentage of time that the glucose level was <70 mg per deciliter or <54 mg per deciliter 3.0 mmol per liter) all met the prespecified hierarchical criterion for significance, favoring the closed-loop system. The mean difference (closed loop minus control) in the percentage of time that the blood glucose level was lower than 70 mg per deciliter was -0.88 percentage points (95% CI, -1.19 to -0.57; P<0.001). The mean adjusted difference in glycated hemoglobin level after 6 months was -0.33 percentage points (95% CI, -0.53 to -0.13; P = 0.001). In the closed-loop group, the median percentage of time that the system was in closed-loop mode was 90% over 6 months. No serious hypoglycemic events occurred in either group; one episode of diabetic ketoacidosis occurred in the closed-loop group.
In this 6-month trial involving patients with type 1 diabetes, the use of a closed-loop system was associated with a greater percentage of time spent in a target glycemic range than the use of a sensor-augmented insulin pump. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases; iDCL ClinicalTrials.gov number, NCT03563313.).
A closed-loop system of insulin delivery (also called an artificial pancreas) may improve glycemic outcomes in children with type 1 diabetes.
In a 16-week, multicenter, randomized, open-label, ...parallel-group trial, we assigned, in a 3:1 ratio, children 6 to 13 years of age who had type 1 diabetes to receive treatment with the use of either a closed-loop system of insulin delivery (closed-loop group) or a sensor-augmented insulin pump (control group). The primary outcome was the percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter, as measured by continuous glucose monitoring.
A total of 101 children underwent randomization (78 to the closed-loop group and 23 to the control group); the glycated hemoglobin levels at baseline ranged from 5.7 to 10.1%. The mean (±SD) percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter increased from 53±17% at baseline to 67±10% (the mean over 16 weeks of treatment) in the closed-loop group and from 51±16% to 55±13% in the control group (mean adjusted difference, 11 percentage points equivalent to 2.6 hours per day; 95% confidence interval, 7 to 14; P<0.001). In both groups, the median percentage of time that the glucose level was below 70 mg per deciliter was low (1.6% in the closed-loop group and 1.8% in the control group). In the closed-loop group, the median percentage of time that the system was in the closed-loop mode was 93% (interquartile range, 91 to 95). No episodes of diabetic ketoacidosis or severe hypoglycemia occurred in either group.
In this 16-week trial involving children with type 1 diabetes, the glucose level was in the target range for a greater percentage of time with the use of a closed-loop system than with the use of a sensor-augmented insulin pump. (Funded by Tandem Diabetes Care and the National Institute of Diabetes and Digestive and Kidney Diseases; ClinicalTrials.gov number, NCT03844789.).
The current COVID-19 pandemic provides an incentive to expand considerably the use of telemedicine for high-risk patients with diabetes, and especially for the management of type 1 diabetes (T1D). ...Telemedicine and digital medicine also offer critically important approaches to improve access, efficacy, efficiency, and cost-effectiveness of medical care for people with diabetes.
Two case reports are presented where telemedicine was used effectively and safely after day 1 in person patient education. These aspects of the management of new-onset T1D patients (adult and pediatric) included ongoing diabetes education of the patient and family digitally. The patients used continuous glucose monitoring with commercially available analysis software (Dexcom Clarity and Glooko) to generate ambulatory glucose profiles and interpretive summary reports. The adult subject used multiple daily insulin injections; the pediatric patient used an insulin pump. The subjects were managed using a combination of e-mail, Internet via Zoom, and telephone calls.
These two cases show the feasibility and effectiveness of use of telemedicine in applications in which we had not used it previously: new-onset diabetes education and insulin dosage management.
The present case reports illustrate how telemedicine can be used safely and effectively for new-onset T1D training and education for both pediatric and adult patients and their families. The COVID-19 pandemic has acutely stimulated the expansion of the use of telemedicine and digital medicine. We conclude that telemedicine is an effective approach for the management of patients with new-onset T1D.
Combining technologies including rapid insulin analogs, insulin pumps, continuous glucose monitors, and control algorithms has allowed for the creation of automated insulin delivery (AID) systems. ...These systems have proven to be the most effective technology for optimizing metabolic control and could hold the key to broadly achieving goal-level glycemic control for people with type 1 diabetes. The use of AID has exploded in the past several years with several options available in the United States and even more in Europe. In this article, we review the largest studies involving these AID systems, and then examine future directions for AID with an emphasis on usability.
The MiniMed 670G System is the first commercial hybrid closed-loop (HCL) system for management of type 1 diabetes. Using data from adolescent and young adult participants, we compared insulin ...delivery patterns and time-in-range metrics in HCL (Auto Mode) and open loop (OL). System alerts, usage profiles, and operational parameters were examined to provide suggestions for optimal clinical use of the system.
Data from 31 adolescent and young adult participants (14-26 years old) at three clinical sites in the 670G pivotal trial were analyzed. Participants had a 2-week run-in period in OL, followed by a 3-month in-home study phase with HCL functionality enabled. Data were compared between baseline OL and HCL use after 1 week, 1 month, 2 months, and 3 months.
Carbohydrate-to-insulin (C-to-I) ratios were more aggressive for all meals with HCL compared with baseline OL. Total daily insulin dose and basal-to-bolus ratio did not change during the trial. Time in range increased 14% with use of Auto Mode after 3 months (
< 0.001), and HbA
decreased 0.75%. Auto Mode exits were primarily due to sensor/insulin delivery alerts and hyperglycemia. The percentage of time in Auto Mode gradually declined from 87%, with a final use rate of 72% (-15%).
In transitioning young patients to the 670G system, providers should anticipate immediate C-to-I ratio adjustments while also assessing active insulin time. Users should anticipate occasional Auto Mode exits, which can be reduced by following system instructions and reliably bolusing for meals. Unique 670G system functionality requires ongoing clinical guidance and education from providers.
Technology for patients with type 1 diabetes (T1D), including continuous glucose monitoring (CGM), insulin pumps, and hybrid closed-loop (HCL) systems, is improving, being used more commonly in the ...pediatric population, and impacts glycemic control.
We evaluated the use of these technologies and their impact on glycemic control among patients with T1D who were seen at the Barbara Davis Center (
= 4003) between January 2018 and December 2020, <22 years old, with diabetes duration >3 months. Data were analyzed by age group and technology-use group defined as multiple daily injection with blood glucose meter (MDI/BGM), pump with BGM (pump/BGM), MDI with CGM (MDI/CGM), and pump with CGM (pump/CGM). Glycemic control was compared using analysis of covariance (ANCOVA) and controlling for diabetes duration, race, and insurance.
Among 4003 patients, 20% used MDI/BGM (mean hemoglobin A1c HbA1c = 10.0%); 14.4% used pump/BGM (mean HbA1c = 10.0%); 15.4% used MDI/CGM (mean HbA1c = 8.6%); and 49.8% used pump/CGM (mean HbA1c = 8.1%). Compared with MDI/BGM patients, MDI/CGM and pump/CGM users had a lower HbA1c and were more likely to reach an HbA1c <7.0% (all
< 0.0001). Among pump/CGM users, 35% used HCL technology (mean HbA1c = 7.6%) and had a lower HbA1c and were more likely to reach an HbA1c <7% than non-HCL users (
< 0.001).
CGM use was associated with a lower HbA1c in both MDI and pump users. Pump use was only associated with a lower HbA1c if used with CGM. HCL was associated with the lowest HbA1c. Spanish language and minority race/ethnicity were associated with lower rates of pump and CGM use, highlighting the need to reduce disparities.
To describe predictors of hybrid closed loop (HCL) discontinuation and perceived barriers to use in youth with type 1 diabetes.
Youth with type 1 diabetes (eligible age 2-25 y; recruited age 8-25 y) ...who initiated the Minimed 670G HCL system were followed prospectively for 6 mo in an observational study.
Demographic, glycemic (time-in-range, HbA1c), and psychosocial variables Hypoglycemia Fear Survey (HFS); Problem Areas in Diabetes (PAID) were collected for all participants. Participants who discontinued HCL (<10% HCL use at clinical visit) completed a questionnaire on perceived barriers to HCL use.
Ninety-two youth (15.7 ± 3.6 y, HbA1c 8.8 ± 1.3%, 50% female) initiated HCL, and 28 (30%) discontinued HCL, with the majority (64%) discontinuing between 3 and 6 mo after HCL start. Baseline HbA1c predicted discontinuation (P = .026) with the odds of discontinuing 2.7 times higher (95% CI: 1.123, 6.283) for each 1% increase in baseline HbA1c. Youth who discontinued HCL rated difficulty with calibrations, number of alarms, and too much time needed to make the system work as the most problematic aspects of HCL. Qualitatively derived themes included technological difficulties (error alerts, not working correctly), too much work (calibrations, fingersticks), alarms, disappointment in glycemic control, and expense (cited by parents).
Youth with higher HbA1c are at greater risk for discontinuing HCL than youth with lower HbA1c, and should be the target of new interventions to support device use. The primary reasons for discontinuing HCL relate to the workload required to use HCL.
Hybrid closed-loop (HCL) artificial pancreas (AP) systems are now moving from research settings to widespread clinical use. In this study, the inControl algorithm developed by TypeZero Technologies ...was embedded to a commercial Tandem t:slim X2 insulin pump, now called Control-IQ, paired with a Dexcom G6 continuous glucose monitor and tested for superiority against sensor augmented pump (SAP) therapy. Both groups were physician-monitored throughout the clinical trial.
In a randomized controlled trial, 24 school-aged children (6-12 years) with type 1 diabetes (T1D) participated in a 3-day home-use trial at two sites: Stanford University and the Barbara Davis Center (50% girls, 9.6 ± 1.9 years of age, 4.5 ± 1.9 years of T1D, baseline hemoglobin A1c 7.35% ± 0.68%). Study subjects were randomized 1:1 at each site to either HCL AP therapy with the Control-IQ system or SAP therapy with remote monitoring.
The primary outcome, time in target range 70-180 mg/dL, using Control-IQ significantly improved (71.0% ± 6.6% vs. 52.8% ± 13.5%; P = 0.001) and mean sensor glucose (153.6 ± 13.5 vs. 180.2 ± 23.1 mg/dL; P = 0.003) without increasing hypoglycemia time <70 mg/dL (1.7% 1.3%-2.1% vs. 0.9% 0.3%-2.7%; not significant). The HCL system was active for 94.4% of the study period. Subjects reported that use of the system was associated with less time thinking about diabetes, decreased worry about blood sugars, and decreased burden in managing diabetes.
The use of the Tandem t:slim X2 with Control-IQ HCL AP system significantly improved time in range and mean glycemic control without increasing hypoglycemia in school-aged children with T1D during remote monitored home use.
Noninvasive Glucose Sensing In Vivo Leung, Ho Man Colman; Forlenza, Gregory P; Prioleau, Temiloluwa O ...
Sensors (Basel, Switzerland),
08/2023, Letnik:
23, Številka:
16
Journal Article
Recenzirano
Odprti dostop
Blood glucose monitoring is an essential aspect of disease management for individuals with diabetes. Unfortunately, traditional methods require collecting a blood sample and thus are invasive and ...inconvenient. Recent developments in minimally invasive continuous glucose monitors have provided a more convenient alternative for people with diabetes to track their glucose levels 24/7. Despite this progress, many challenges remain to establish a noninvasive monitoring technique that works accurately and reliably in the wild. This review encompasses the current advancements in noninvasive glucose sensing technology in vivo, delves into the common challenges faced by these systems, and offers an insightful outlook on existing and future solutions.