1.
  • TH‐C‐218‐02: Cranial SRS an... TH‐C‐218‐02: Cranial SRS and SRT on a Siemens Artist Using the Brainlab IPlan Treatment Planning System
    Gayou, O Medical Physics, June 2012, Letnik: 39, Številka: 6
    Conference Proceeding, Journal Article
    Recenzirano

    Linear accelerator‐based stereotactic radiosurgery (SRS) or radiotherapy (SRT) is a well accepted technique for the treatment of cranial primary and metastatic lesions and acoustic neuromas. The ...
Celotno besedilo
2.
Celotno besedilo
3.
  • SU‐E‐J‐152: Fluoroscopic Tr... SU‐E‐J‐152: Fluoroscopic Treatment Verification for Gated Stereotactic Body Radiation Therapy of a Tumor Located Near the Dome of the Liver: A
    Study, Case; Gayou, O; Christensen, J ... Medical Physics, June 2013, Letnik: 40, Številka: 6
    Conference Proceeding, Journal Article
    Recenzirano

    Purpose: To describe a method using pretreatment and intrafraction fluoroscopic verification of the gated treatment of a liver lesion located near the diaphragm. Methods: A 74‐year‐old female ...
Celotno besedilo
4.
  • Probing the high momentum c... Probing the high momentum component of the deuteron at high Q2
    Boeglin, W U; Coman, L; Ambrozewicz, P ... Physical review letters, 2011-Dec-23, Letnik: 107, Številka: 26
    Journal Article
    Recenzirano

    The (2)H(e,e'p)n cross section at a momentum transfer of 3.5 (GeV/c)(2) was measured over a kinematical range that made it possible to study this reaction for a set of fixed missing momenta as a ...
Celotno besedilo

PDF
5.
  • SU‐D‐BRA‐02: Penumbra Measu... SU‐D‐BRA‐02: Penumbra Measurement for a Flattening‐Filter‐Free Artiste Linear Accelerator
    Gayou, O; Johnson, M Medical Physics, June 2011, Letnik: 38, Številka: 6
    Conference Proceeding, Journal Article
    Recenzirano

    Purpose: The primary benefit of removing the flattening filter of a linear accelerator is to increase the dose rate by a factor of 3 to 6. Additionally, change in scatter conditions in the head of ...
Celotno besedilo
6.
Celotno besedilo
7.
  • SU‐GG‐T‐582: Comparison of ... SU‐GG‐T‐582: Comparison of Dose Based and Biological Based Treatment Planning Systems for the Siemens Artiste Linear Accelerator
    Day, E; Gayou, O Medical Physics, June 2010, Letnik: 37, Številka: 6
    Conference Proceeding, Journal Article
    Recenzirano

    Purpose: To compare the performance of the biological‐based treatment planning system (TPS) CMS Monaco with the dose‐based TPS CMS XiO, for treatment of head and neck patients on the Siemens Artiste ...
Celotno besedilo
8.
  • SU‐GG‐J‐33: Localizing a Mo... SU‐GG‐J‐33: Localizing a Moving Tumor Using MV‐CBCT
    Gayou, O; Colonias, A Medical Physics, June 2010, Letnik: 37, Številka: 6
    Conference Proceeding, Journal Article
    Recenzirano

    Purpose: To evaluate mega‐voltage cone‐beam computed tomography (MV‐CBCT) imaging of moving tumors. Method and Materials: Five patients treated for early stage non‐small cell lung cancer using ...
Celotno besedilo
9.
  • SU‐GG‐T‐522: Investigation ... SU‐GG‐T‐522: Investigation of Intracranial Localization for SRS and SRT Using MV‐CBCT
    Johnson, M; Gayou, O Medical Physics, June 2010, Letnik: 37, Številka: 6
    Conference Proceeding, Journal Article
    Recenzirano

    Purpose: To investigate the accuracy and precision of Mega‐Voltage Cone Beam Computed Tomography (MV‐CBCT) localization for intracranial stereotactic treatment deliveries. Method and Materials: A ...
Celotno besedilo
10.
  • SU‐FF‐I‐19: Mega‐Voltage Co... SU‐FF‐I‐19: Mega‐Voltage Cone‐Beam Computed Tomography Image Quality: Effects of Scan Length and Monitor Units Per Projection
    Gayou, O; Akpati, H Medical Physics, June 2009, Letnik: 36, Številka: 6
    Conference Proceeding, Journal Article
    Recenzirano

    Purpose: To present a quantitative evaluation of the impact of scan length, monitor unit (MU)/projection, and total MU on the image quality in mega‐voltage cone‐beam computed tomography (MV‐CBCT). We ...
Celotno besedilo