CERN has been building a transportable RFQ for use in the examination of art masterpieces based mainly on the PIXE (Proton Induced X-ray Emission) technique with an extracted beam. This new PIXE-RFQ ...accelerator is very compact, only one meter in length with a power consumption of less than 6 kVA for a beam energy of 2 MeV and an average current of 5 nA. The PIXE-RFQ will be used for the MACHINA (Movable Accelerator for Cultural Heritage In-situ Non-destructive Analysis) project developed jointly by CERN and INFN. This paper will present the detailed design and performances of the PIXE-RFQ as well as the fabrication technologies used and the current status of the project. The beam size and the peak current/duty cycle of the RFQ have been optimised for the Ion Beam Analysis (IBA) of artwork objects.
The New IRAM KID Arrays 2 (NIKA2) consortium has just finished installing and commissioning a millimetre camera on the IRAM 30-m telescope. It is a dual-band camera operating with three ...frequency-multiplexed kilo-pixels arrays of lumped element kinetic inductance detectors (LEKID) cooled at 150 mK, designed to observe the intensity and polarisation of the sky at 260 and 150 GHz (1.15 and 2 mm). NIKA2 is today an IRAM resident instrument for millimetre astronomy, such as intracluster medium from intermediate to distant clusters and so for the follow-up of Planck satellite detected clusters, high redshift sources and quasars, early stages of star formation and nearby galaxies emission. We present an overview of the instrument performance as it has been evaluated at the end of the commissioning phase.
Oestrus induction in various canine breeds was attempted in 32 bitches. A group of 8 bitches were treated 80–160 d following their previous oestrus (G1) whereas a second group of 24 bitches (G2) were ...implanted 200–590 d following their previous oestrus. The treatment for each bitch consisted in one Deslorelin implant (Suprelorin®4,7mg, Virbac, France), inserted subcutaneously in the post-umbilical region. Ovulation, pregnancy rate and litter size were recorded. All bitches came in heat 4.3 ± 1.4 d after implantation (2–7 d). Ovulation was reported in 62.5% in G1 and 87.5% in G2. One bitch refused mating and since no AI was performed, she was not considered for further analysis. Pregnancy was obtained in 25% in G1 versus 78.3% in G2. Mean litter size was 6.7 ± 3.5 puppies (1–14). Luteal failure was suspected in 3 bitches, two that remained non-pregnant and one which aborted 58 d post-ovulation since the owner refused progesterone supplementation. Deslorelin implants can therefore be considered as a valuable alternative to induce fertile oestrus in bitches in anoestrus. Follow-up of the luteal phase is recommended, since some bitches might encounter luteal failure.
Mechanical testing of materials at low temperatures is one of the cornerstones of the Mechanical and Materials Engineering (MME) group at CERN. A long tradition of more than 20 years and a unique ...know - how of such tests has been developed with an 18 kN double-walled cryostat. Large campaigns of material qualification have been carried out and the mechanical behaviour of materials at 4 K has been vastly studied in sub - size samples for projects like LEP, LHC and its experiments. With the aim of assessing the mechanical properties of materials of higher strength and or issued from heavy gauge products for which testing standardized specimens of larger cross section might be more adapted, a new 100 kN cryostat capable of hosting different shapes of normalized samples has been carefully designed and fabricated inhouse together with the associated tooling and measurement instrumentation. It has been conceived to be able to adapt to different test frames both dynamic and static, which will be of paramount importance for future studies of fracture mechanics at low temperatures. The cryostat features a double-walled vessel consisting of a central cylindrical section with a convex lower end and a flat top end closure. The transmission of the load is guaranteed by a 4 column system and its precise monitoring is assured by an internal load cell positioned next to the sample in the load train. This innovative approach will be discussed together with other nonconventional instrumentation solutions. A validation of the whole system has been carried out, where bending efforts on instrumented samples have been measured. Additionally, dedicated tooling has been fabricated for the device's optimization. The preliminary results obtained confirm an excellent performance of the system and enhance the analysis of materials under extreme conditions with state of the art instrumentation.
We study quantum reflection of antihydrogen atoms from matter slabs due to the van der Waals/Casimir-Polder (vdW/CP) potential. By taking into account the specificities of antihydrogen and the ...optical properties and width of the slabs we calculate realistic estimates for the potential and quantum reflection amplitudes. Next we discuss the paradoxical result of larger reflection coefficients estimated for weaker potentials in terms of the Schwarzian derivative. We analyze the limiting case of reflections at small energies, which are characterized by a scattering length and have interesting applications for trapping and guiding antihydrogen using material walls.
The degradation mechanisms of state-of-the-art Nb-Ti/Cu superconductors are described, based on in-situ synchrotron X-ray diffraction measurements during heat treatment. A quantitative description of ...the Nb-Ti/Cu degradation in terms of critical current density, Cu stabiliser resistivity and mechanical composite strength is presented. In an applied magnetic field a significant critical current degradation is already observed after a 5-minute 400 °C heat treatment, due to variations of –Ti precipitate size and distribution within the Nb-Ti alloy filaments. A strong degradation of the strand mechanical properties is observed after several minutes heating above 550 °C, which is also the temperature at which the formation of Cu-Ti intermetallic phases is detected. Several minutes heating at 250 °C are sufficient to increase the RRR of the strongly cold work strands inside a Rutherford type cable from about 80 to about 240. Heating for several minutes at 400 °C does not cause a significant conductor degradation in self-field and, thus, leaves enough temperature margin for the electrical interconnection of Nb-Ti/Cu conductors with common low temperature solders.