A phenomenological renormalization scheme for hadronic diffraction is proposed, which unitarizes the triple-pomeron Regge amplitude while preserving its
M
2 and
t dependence. Predictions for
pp
p
p
...single diffractive, double diffractive and double pomeron exchange cross sections are presented and compared with experimental results. A new interpretation of hard and deep inelastic diffractive data emerges in which the momentum sum rule is obeyed by the constituents of a pomeron described as a mixture of quark and gluon color singlets in a ratio dictated by asymptopia.
Using Regge theory at Born level and with eikonalized amplitudes we obtain for the pomeron intercept the values 1.104 and 1.122, respectively, from global fits to total cross section and ϱ-value data ...for
p
±
p,
π
±
p and
K
±
p.
Shower maximum detector for the CDF plug upgrade calorimeter Apollinari, G.; Goulianos, K.; Melese, P. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
08/1998, Letnik:
412, Številka:
2
Journal Article
Recenzirano
We describe a detector designed to measure the position of electrons and photons in the new CDF Plug Upgrade Calorimeter. The detector comprises 6400 individual scintillator strips placed at the ...shower maximum location of the electromagnetic calorimeter section and coupled to wave-length-shifting fibers read-out by multi-anode photomultipliers. We describe the design criteria, the R&D studies that led to the choice of scintillator and fiber, the mechanical assembly, and the quality control tests during production and assembly of the detector elements.
The CDF MiniPlug calorimeters at the Tevatron Goulianos, K.; Gallinaro, M.; Hatakeyama, K. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
02/2004, Letnik:
518, Številka:
1
Journal Article
Recenzirano
Odprti dostop
Two MiniPlug calorimeters, designed to measure the energy and lateral position of particles in the pseudorapidity region of 3.6<|
η|<5.1 of the CDF detector, have been installed as part of the Run II ...CDF upgrade at the Tevatron collider. Detector performance and first results from p̄p collision data are presented.
The CDF MiniPlug calorimeters Goulianos, K; Gallinaro, M; Hatakeyama, K ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
01/2003, Letnik:
496, Številka:
2
Journal Article
Recenzirano
Odprti dostop
Two MiniPlug calorimeters, designed to measure the energy and lateral position of particles in the (forward) pseudorapidity region of 3.6<|
η|<5.1 of the CDF detector, have been recently installed as ...part of the Run II CDF upgrade at the Tevatron
p
̄
p
collider. In this paper we describe the final design of the MiniPlugs and present results from a cosmic ray test, in which a light yield of approximately
100
pe/
MIP
was obtained, exceeding our design requirements.