Aging studies for the ATLAS Transition Radiation Tracker (TRT) Akesson, T.; Barberio, E.; Bondarenko, V. ...
International Workshop on Aging Phenomena in Gaseous Detectors,Hamburg, Germany,2001-10-02 - 2001-10-05,
12/2003, Letnik:
515, Številka:
1
Journal Article, Conference Proceeding
Recenzirano
Odprti dostop
A summary of the aging and material validation studies carried out for the ATLAS Transition Radiation Tracker (TRT) is presented. Particular emphasis is put on the different phenomena observed in ...straw tubes operating with the chosen Xe/CF
4/CO
2 mixture. The most serious effects observed are silicon deposition on the anode wire and damage of the anode wire gold plating. Etching phenomena and active radical effects are also discussed. With a careful choice of all materials and components, and with good control of the water contamination in the active gas, the ATLAS TRT will operate reliably for 10 years at the LHC design luminosity. To demonstrate this fully, more work is still needed on the gas system purification elements, in particular to understand their interplay with the active species containing fluorine created in the avalanche process under irradiation.
Test-beam studies of the ATLAS Transition Radiation Tracker (TRT) straw tube performance in terms of electron–pion separation using a time-over-threshold method are described. The test-beam data are ...compared with Monte Carlo simulations of charged particles passing through the straw tubes of the TRT. For energies below
10
GeV
, the time-over-threshold method combined with the standard transition-radiation cluster-counting technique significantly improves the electron–pion separation in the TRT. The use of the time-over-threshold information also provides some kaon–pion separation, thereby significantly enhancing the B-physics capabilities of the ATLAS detector.
The basic drift-time measurement properties of the proportional tubes (straws) of the ATLAS TRT detector and the impact of the parameters of the front-end electronics on performance are discussed. ...The performance of two different front-end electronics prototypes has been studied in detail at very high counting rate and is reported here.
An X-ray scanner for wire chambers Akesson, T.; Arik, E.; Assamagan, K. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
2003, Letnik:
507, Številka:
3
Journal Article
Recenzirano
The techniques to measure the position of sense wires and field wires, the gas gain and the gas flow rate inside wire chambers using a collimated and filtered X-ray beam are reported. Specific ...examples are given using barrel modules of the Transition Radiation Tracker of the ATLAS experiment.
A prototype of the Transition Radiation Tracker (TRT) for the ATLAS experiment at the CERN LHC has been built and tested at the CERN SPS. Detailed studies of the drift-time measurements, alignment ...technique, hit registration efficiency, track and momentum accuracy were performed. A coordinate measurement accuracy of
150
μm
for a single TRT drift tube and momentum resolution of 0.8% for
20
GeV
pions in a
1.56
T
magnetic field were achieved. The results obtained are in agreement with the expected tracking performance of the ATLAS TRT.
The transition radiation tracker (TRT) is one of three particle tracking detectors now under construction for the ATLAS experiment, whose goal is to exploit the highly exciting new physics potential ...at CERN's next accelerator, the so called Large Hadron Collider (LHC). The TRT consists of 370000 straw proportional tubes of 4 mm diameter with a 30 micron thick anode wire, which will be operated with a Xe/CO 2 /O 2 gas mixture at a high voltage of approximately 1.5 kV. While the construction of the TRT is now well under way, a number of interesting and challenging questions need to be solved with regard to wire aging phenomena, which are induced by pollution originating from very small amounts of silicon-based vacuum materials in some components of the gas system. Finally a guideline to avoid aging in wire chamber detectors in high luminosity experiments is given