It is unknown whether transcatheter valves will have similar durability as surgical bioprosthetic valves. Definitions of structural valve deterioration (SVD), based on valve related reintervention or ...death, underestimate the incidence of SVD.
This study sought to determine and compare the 5-year incidence of SVD, using new standardized definitions based on echocardiographic follow-up of valve function, in intermediate-risk patients with severe aortic stenosis given transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) in the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and registry.
In the PARTNER 2A trial, patients were randomly assigned to receive either TAVR with the SAPIEN XT or SAVR, whereas in the SAPIEN 3 registry, patients were assigned to TAVR with the SAPIEN 3. The primary endpoint was the incidence of SVD, that is, the composite of SVD-related hemodynamic valve deterioration during echocardiographic follow-up and/or SVD-related bioprosthetic valve failure (BVF) at 5 years.
Compared with SAVR, the SAPIEN-XT TAVR cohort had a significantly higher 5-year exposure adjusted incidence rates (per 100 patient-years) of SVD (1.61 ± 0.24% vs. 0.63 ± 0.16%), SVD-related BVF (0.58 ± 0.14% vs. 0.12 ± 0.07%), and all-cause (structural or nonstructural) BVF (0.81 ± 0.16% vs. 0.27 ± 0.10%) (p ≤ 0.01 for all). The 5-year rates of SVD (0.68 ± 0.18% vs. 0.60 ± 0.17%; p = 0.71), SVD-related BVF (0.29 ± 0.12% vs. 0.14 ± 0.08%; p = 0.25), and all-cause BVF (0.60 ± 0.15% vs. 0.32 ± 0.11%; p = 0.32) in SAPIEN 3 TAVR were not significantly different to a propensity score matched SAVR cohort. The 5-year rates of SVD and SVD-related BVF were significantly lower in SAPIEN 3 versus SAPIEN XT TAVR matched cohorts.
Compared with SAVR, the second-generation SAPIEN XT balloon-expandable valve has a higher 5-year rate of SVD, whereas the third-generation SAPIEN 3 has a rate of SVD that was not different from SAVR. (The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves - PII A PARTNERII A; NCT01314313; The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - PARTNER II - PARTNERII - S3 Intermediate PARTNERII S3i; NCT03222128)
Display omitted
Phase contrast (PC) cardiovascular magnetic resonance (CMR) in the ascending aorta (AAo) is widely used to calculate left ventricular (LV) stroke volume (SV). The accuracy of PC CMR may be altered by ...turbulent flow. Measurement of SV at another site is suggested in the presence of aortic stenosis, but very few data validates the accuracy or inaccuracy of PC in that setting. Our objective is to compare flow measurements obtained in the AAo and LV outflow tract (LVOT) in patients with aortic stenosis.
Retrospective analysis of patients with aortic stenosis who had CMR and echocardiography. Patients with mitral regurgitation were excluded. PC in the AAo and LVOT were acquired to derive SV. LV SV from end-systolic and end-diastolic tracings was used as the reference measure. A difference ≥ 10% between the volumetric method and PC derived SVs was considered discordant. Metrics of turbulence and jet eccentricity were assessed to explore the predictors of discordant measurements.
We included 88 patients, 41% with bicuspid aortic valve. LVOT SV was concordant with the volumetric method in 79 (90%) patients vs 52 (59%) patients for AAo SV (p = 0.015). In multivariate analysis, aortic stenosis flow jet angle was a strong predictor of discordant measurement in the AAo (p = 0.003). Mathematical correction for the jet angle improved the concordance from 59 to 91%. Concordance was comparable in patients with bicuspid and trileaflet valves (57% and 62% concordance respectively; p = 0.11). Accuracy of SV measured in the LVOT was not influenced by jet eccentricity. For aortic regurgitation quantification, PC in the AAo had better correlation to volumetric assessments than LVOT PC.
LVOT PC SV in patients with aortic stenosis and eccentric jet might be more accurate compared to the AAo SV. Mathematical correction for the jet angle in the AAo might be another alternative to improve accuracy.
Aortic stenosis (AS) is a disease of the valve and the myocardium. A correct assessment of the valve disease severity is key to define the need for aortic valve replacement (AVR), but a better ...understanding of the myocardial consequences of the increased afterload is paramount to optimize the timing of the intervention. Transthoracic echocardiography remains the cornerstone of AS assessment, as it is universally available, and it allows a comprehensive structural and hemodynamic evaluation of both the aortic valve and the rest of the heart. However, it may not be sufficient as a significant proportion of patients with severe AS presents with discordant grading (i.e., an AVA ≤ 1 cm
and a mean gradient <40 mmHg) which raises uncertainty about the true severity of AS and the need for AVR. Several imaging modalities (transesophageal or stress echocardiography, computed tomography, cardiovascular magnetic resonance, positron emission tomography) exist that allow a detailed assessment of the stenotic aortic valve and the myocardial remodeling response. This review aims to provide an updated overview of these multimodality imaging techniques and seeks to highlight a practical approach to help clinical decision making in the challenging group of patients with discordant low-gradient AS.
Sex-specific thresholds of computed tomography (CT)–derived aortic valve calcification (AVC) or AVC density (AVCd) to identify severe aortic stenosis (AS) have been established in populations that ...consisted mainly of Caucasians with a tricuspid aortic valve. The objective of this study was to evaluate the accuracy (i.e., sensitivity and specificity) of previously established thresholds to identify severe AS in patients with bicuspid aortic valve (BAV) and according to ethnicity: Caucasian vs. Asian.
We built a multicenter registry of echocardiographic and CT data collected in BAV patients with at least mild AS and preserved left ventricular ejection fraction from 7 different centers. Anatomic severity of AS obtained by CT-derived AVC and AVCd was compared to hemodynamic severity of AS obtained by echocardiography.
Among 485 BAV patients (60% men, 73% Asians), the best thresholds of AVC and AVCd to identify severe AS in BAV patients were 2315 arbitrary units (AU) (sensitivity Se/specificity Spe = 82/78%) in men, 1103 AU (Se/Spe = 80/82%) in women, and 561 AU/cm2 (Se/Spe = 86/91%) in men, and 301 AU/cm2 (Se/Spe = 83/82%) in women, respectively. According to ethnicity, thresholds for severe AS in Caucasian patients were, respectively, in men and women: 2208 AU (Se/Spe = 83/83%) and 1230 AU (Se/Spe = 87/82%) for AVC and 474 AU/cm2 (Se/Spe = 88/83%) and 358 AU/cm2 (Se/Spe = 80/82%) for AVCd. In Asian patients, they were 2582 AU (Se/Spe = 76/78%) and 924 AU (Se/Spe = 84/80%) for AVC and 640 AU/cm2 (Se/Spe = 82/89%) and 255 AU/cm2 (Se/Spe = 86/80%) for AVCd.
The optimal thresholds to identify hemodynamically severe AS in BAV patients are similar in Caucasians but appear to be higher in Asian men, compared with thresholds previously reported in tricuspid aortic valve patients. Nonetheless, the thresholds currently proposed in the guidelines have good accuracy and can be applied in BAV patients to confirm AS severity.
The first-line evaluation of aortic stenosis severity is Doppler echocardiography. However, in up to 40% of patients, resting echocardiographic assessment of aortic stenosis severity is discordant, ...leading to clinical uncertainty. Interest has therefore grown in aortic valve calcium scoring by multidetector computed tomography (CT-AVC) as an alternative load independent assessment of aortic stenosis severity. This paper will briefly review the pathophysiology of aortic stenosis and the crucial role that calcification plays in driving progressive obstruction of the valve. Subsequently, it will describe published reports that have investigated CT-AVC, validating this parameter against histology, and establishing its diagnostic accuracy versus echocardiography as well as its powerful independent prognostic capability. Finally, this review seeks to provide a practical guide about how best to acquire and interpret CT-AVC with a close focus on potential pitfalls and how these might be best avoided as this technique becomes more widely adopted in to clinical practice.
Display omitted
•Measurement of aortic valve calcification is useful in assessing aortic stenosis severity in patients for whom echocardiography is not conclusive.•Aortic valve calcification should be measured on noncontrast electrocardiogram-gated computer tomography scans (120 kV to 140 kV; 60% to 80% RR interval) with the use of the Agatston method.•Calcification of left ventricular outflow tract, aorta, mitral annulus, and coronary arteries should carefully be excluded from the measurement of aortic valve calcification.•An aortic valve calcification score higher than 1,300 AU in women or 2,000 AU in men should be considered severe.
Background and objectivesTranscatheter aortic valve-in-valve implantation (ViV) has emerged as a valuable technique to treat failed surgical bioprostheses (BPs) in patients with high risk for redo ...surgical aortic valve replacement (SAVR). Small BP size (≤21 mm), stenotic pattern of degeneration and pre-existing prosthesis–patient mismatch (PPM) have been associated with worse clinical outcomes after ViV. However, no study has evaluated the actual haemodynamic benefit associated with ViV. This study aims to compare haemodynamic status observed at post-ViV, pre-ViV and early after initial SAVR and to determine the factors associated with worse haemodynamic outcomes following ViV, including the rates of high residual gradient and ‘haemodynamic futility’.MethodsEarly post-SAVR, pre-ViV and post-ViV echocardiographic data of 79 consecutive patients who underwent aortic ViV at our institution were retrospectively analysed. The primary study endpoint was suboptimal valve haemodynamics (SVH) following ViV defined by the Valve Academic Research Consortium 2 as the presence of high residual aortic mean gradient (≥20 mm Hg) and/or at least moderate aortic regurgitation (AR). Haemodynamic futility of ViV was defined as <10 mm Hg decrease in mean aortic gradient and no improvement in AR compared with pre-ViV.ResultsSVH was found in 61% of patients (57% high residual gradient, 4% moderate AR) after ViV versus 24% early after SAVR. Pre-existing PPM and BP mode of failure by stenosis were independently associated with the primary endpoint (OR: 2.87; 95% CI 1.08 to 7.65; p=0.035 and OR: 3.02; 95% CI 1.08 to 8.42; p=0.035, respectively) and with the presence of high residual gradient (OR: 4.38; 95% CI 1.55 to 12.37; p=0.005 and OR: 5.37; 95% CI 1.77 to 16.30; p=0.003, respectively) following ViV. Criteria of ViV haemodynamic futility were met in 7.6% overall and more frequently in patients with pre-existing PPM and stenotic BP (18.5%) compared with other patients (2.0%). ViV restored haemodynamic function to early post-SAVR level in only 34% of patients.ConclusionAlthough ViV was associated with significant haemodynamic improvement compared with pre-ViV in >90% of patients, more than half harboured SVH outcome. Furthermore, only one-third of patients had a restoration of valve haemodynamic function to the early post-SAVR level. Pre-existing PPM and stenosis pattern of BP degeneration were the main factors associated with SVH and haemodynamic futility following ViV. These findings provide strong support for the prevention of PPM at the time of initial SAVR and careful preprocedural patient screening.
Purpose of Review
Pericardial diseases include a wide range of pathologies and their diagnosis can often be challenging. The goal of this review is to describe the established and emerging CMR ...imaging techniques used in the assessment of common pericardial diseases and explain the role of pericardial characterization in their diagnosis and management.
Recent Findings
CMR is indicated in cases of diagnostic uncertainty and for a comprehensive evaluation of the pericardium and its impact on the heart. This includes assessment of pericardial anatomy and associated cardiac hemodynamics, quantification and characterization of an effusion, disease staging, tissue characterization, guiding management, and even prognostication in some diseases of the pericardium.
Summary
An emerging technique, pericardial characterization, utilizes various sequences to diagnose and stage pericardial inflammation, act as a biomarker in recurrent pericarditis, and guide management in inflammatory pericardial conditions. Beyond imaging, it has ushered in an era of tailored therapy for patients with pericardial diseases. Future directions should aim at exploring the role of tissue characterization in various pericardial diseases.
The respective impacts of transvalvular flow, gradient, sex, and their interactions on mortality in patients with severe aortic stenosis undergoing surgical aortic valve replacement (AVR) are ...unknown.
This study sought to compare the impact of pre-operative flow-gradient patterns on mortality after AVR and to examine whether there are sex differences.
This study analyzed clinical, echocardiographic, and outcome data prospectively collected in 1,490 patients (544 women 37%), with severe aortic stenosis and preserved left ventricular ejection fraction who underwent AVR.
In this cohort, 601 patients (40%) had normal flow (NF) with high gradient (HG), 405 (27%) NF with low gradient (LG), 246 (17%) paradoxical low flow (LF)/HG, and 238 (16%) LF/LG. During a median follow-up of 2.42 years (interquartile range: 1.04 to 4.29 years), 167 patients died. Patients with LF/HG exhibited the highest mortality after AVR (hazard ratio HR: 2.01; 95% confidence interval CI: 1.33 to 3.03; p < 0.01), which remained significant after multivariate adjustment (HR: 1.96; 95% CI: 1.29 to 2.98; p < 0.01). Both LF/LG and NF/LG patients had comparable outcome to NF/HG (p ≥ 0.47). Optimal thresholds of stroke volume index were obtained for men (40 ml/m2) and women (32 ml/m2). Using these sex-specific cutpoints, paradoxical LF was independently associated with increased mortality in both women (adjusted HR: 2.05; 95% CI: 1.21 to 3.47; p < 0.01) and men (adjusted HR: 1.54; 95% CI: 1.02 to 2.32; p = 0.042), whereas guidelines’ threshold (35 ml/m2) does not.
Paradoxical LF/HG was associated with higher mortality following AVR, suggesting that a reduced flow is a marker of disease severity even in patients with HG aortic stenosis. Early surgical AVR (i.e., before gradient attains 40 mm Hg) might be preferable in these patients. Furthermore, the use of sex-specific thresholds (<40 ml/m2 for men and <32 ml/m2 for women) to define low-flow outperforms the guidelines’ threshold of 35 ml/m2 in risk stratification after AVR.
Display omitted