A side-by-side comparison of Daya Bay antineutrino detectors Bai, J.Z.; Balantekin, A.B.; Cao, G.F. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
09/2012, Letnik:
685
Journal Article
Recenzirano
Odprti dostop
The Daya Bay Reactor Neutrino Experiment is designed to determine precisely the neutrino mixing angle θ13 with a sensitivity better than 0.01 in the parameter sin22θ13 at the 90% confidence level. To ...achieve this goal, the collaboration will build eight functionally identical antineutrino detectors. The first two detectors have been constructed, installed and commissioned in Experimental Hall 1, with steady data-taking beginning September 23, 2011. A comparison of the data collected over the subsequent three months indicates that the detectors are functionally identical, and that detector-related systematic uncertainties are smaller than requirements.
Searches for electron antineutrino, muon neutrino, and muon antineutrino disappearance driven by sterile neutrino mixing have been carried out by the Daya Bay and MINOS+ collaborations. This Letter ...presents the combined results of these searches, along with exclusion results from the Bugey-3 reactor experiment, framed in a minimally extended four-neutrino scenario. Significantly improved constraints on the θμe mixing angle are derived that constitute the most constraining limits to date over five orders of magnitude in the mass-squared splitting Δm241, excluding the 90% C.L. sterile-neutrino parameter space allowed by the LSND and MiniBooNE observations at 90% CLs for Δm241 < 13 eV2. Furthermore, the LSND and MiniBooNE 99% C.L. allowed regions are excluded at 99% CLs for Δm241 < 1.6 eV2.
A measurement of electron antineutrino oscillation by the Daya Bay Reactor Neutrino Experiment is described in detail. Six 2.9-GWth nuclear power reactors of the Daya Bay and Ling Ao nuclear power ...facilities served as intense sources of ν¯e’s. Comparison of the ν¯e rate and energy spectrum measured by antineutrino detectors far from the nuclear reactors (∼1500–1950 m) relative to detectors near the reactors (∼350–600 m) allowed a precise measurement of ν¯e disappearance. More than 2.5 million ν¯e inverse beta-decay interactions were observed, based on the combination of 217 days of operation of six antineutrino detectors (December, 2011–July, 2012) with a subsequent 1013 days using the complete configuration of eight detectors (October, 2012–July, 2015). The ν¯e rate observed at the far detectors relative to the near detectors showed a significant deficit, R=0.949±0.002(stat)±0.002(syst). The energy dependence of ν¯e disappearance showed the distinct variation predicted by neutrino oscillation. Analysis using an approximation for the three-flavor oscillation probability yielded the flavor-mixing angle sin22θ13=0.0841±0.0027(stat)±0.0019(syst) and the effective neutrino mass-squared difference of |Δmee2|=(2.50±0.06(stat)±0.06(syst))×10−3 eV2. Analysis using the exact three-flavor probability found Δm322=(2.45±0.06(stat)±0.06(syst))×10−3 eV2 assuming the normal neutrino mass hierarchy and Δm322=(−2.56±0.06(stat)±0.06(syst))×10−3 eV2 for the inverted hierarchy.
This Letter reports the first extraction of individual antineutrino spectra from ^{235}U and ^{239}Pu fission and an improved measurement of the prompt energy spectrum of reactor antineutrinos at ...Daya Bay. The analysis uses 3.5×10^{6} inverse beta-decay candidates in four near antineutrino detectors in 1958 days. The individual antineutrino spectra of the two dominant isotopes, ^{235}U and ^{239}Pu, are extracted using the evolution of the prompt spectrum as a function of the isotope fission fractions. In the energy window of 4-6 MeV, a 7% (9%) excess of events is observed for the ^{235}U (^{239}Pu) spectrum compared with the normalized Huber-Mueller model prediction. The significance of discrepancy is 4.0σ for ^{235}U spectral shape compared with the Huber-Mueller model prediction. The shape of the measured inverse beta-decay prompt energy spectrum disagrees with the prediction of the Huber-Mueller model at 5.3σ. In the energy range of 4-6 MeV, a maximal local discrepancy of 6.3σ is observed.
A measurement of the energy dependence of antineutrino disappearance at the Daya Bay reactor neutrino experiment is reported. Electron antineutrinos (ν¯(e)) from six 2.9 GW(th) reactors were ...detected with six detectors deployed in two near (effective baselines 512 and 561 m) and one far (1579 m) underground experimental halls. Using 217 days of data, 41 589 (203 809 and 92 912) antineutrino candidates were detected in the far hall (near halls). An improved measurement of the oscillation amplitude sin(2)2θ(13)=0.090(-0.009)(+0.008) and the first direct measurement of the ν¯(e) mass-squared difference |Δm(ee)2|=(2.59(-0.20)(+0.19))×10(-3) eV2 is obtained using the observed ν¯(e) rates and energy spectra in a three-neutrino framework. This value of |Δm(ee)2| is consistent with |Δm(μμ)2| measured by muon neutrino disappearance, supporting the three-flavor oscillation model.
The muon system of the Daya Bay Reactor antineutrino experiment An, F.P.; Beriguete, W.; Blyth, S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
02/2015, Letnik:
773
Journal Article
Recenzirano
Odprti dostop
The Daya Bay experiment consists of functionally identical antineutrino detectors immersed in pools of ultrapure water in three well-separated underground experimental halls near two nuclear reactor ...complexes. These pools serve both as shields against natural, low-energy radiation, and as water Cherenkov detectors that efficiently detect cosmic muons using arrays of photomultiplier tubes. Each pool is covered by a plane of resistive plate chambers as an additional means of detecting muons. Design, construction, operation, and performance of these muon detectors are described.
To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical ...properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and <0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. To bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. This enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.
We present a new determination of the smallest neutrino mixing angle θ_{13} and the mass-squared difference Δm_{32}^{2} using a final sample of 5.55×10^{6} inverse beta-decay (IBD) candidates with ...the final-state neutron captured on gadolinium. This sample is selected from the complete dataset obtained by the Daya Bay reactor neutrino experiment in 3158 days of operation. Compared to the previous Daya Bay results, selection of IBD candidates has been optimized, energy calibration refined, and treatment of backgrounds further improved. The resulting oscillation parameters are sin^{2}2θ_{13}=0.0851±0.0024, Δm_{32}^{2}=(2.466±0.060)×10^{-3} eV^{2} for the normal mass ordering or Δm_{32}^{2}=-(2.571±0.060)×10^{-3} eV^{2} for the inverted mass ordering.
Neutrons produced by cosmic ray muons are an important background for underground experiments studying neutrino oscillations, neutrinoless double beta decay, dark matter, and other rare-event ...signals. A measurement of the neutron yield in the three different experimental halls of the Daya Bay Reactor Neutrino Experiment at varying depth is reported. The neutron yield in Daya Bay’s liquid scintillator is measured to be Yn=(10.26±0.86)×10−5, (10.22±0.87)×10−5, and (17.03±1.22)×10−5 μ−1 g−1 cm2 at depths of 250, 265, and 860 meters-water-equivalent. These results are compared to other measurements and the simulated neutron yield in Fluka and Geant4. A global fit including the Daya Bay measurements yields a power law coefficient of 0.77±0.03 for the dependence of the neutron yield on muon energy.
The detector system of the Daya Bay reactor neutrino experiment An, F.P.; Chan, W.T.; Chasman, C. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
03/2016, Letnik:
811
Journal Article
Recenzirano
Odprti dostop
The Daya Bay experiment was the first to report simultaneous measurements of reactor antineutrinos at multiple baselines leading to the discovery of ν¯e oscillations over km-baselines. Subsequent ...data has provided the world׳s most precise measurement of sin22θ13 and the effective mass splitting Δmee2. The experiment is located in Daya Bay, China where the cluster of six nuclear reactors is among the world׳s most prolific sources of electron antineutrinos. Multiple antineutrino detectors are deployed in three underground water pools at different distances from the reactor cores to search for deviations in the antineutrino rate and energy spectrum due to neutrino mixing. Instrumented with photomultiplier tubes, the water pools serve as shielding against natural radioactivity from the surrounding rock and provide efficient muon tagging. Arrays of resistive plate chambers over the top of each pool provide additional muon detection. The antineutrino detectors were specifically designed for measurements of the antineutrino flux with minimal systematic uncertainty. Relative detector efficiencies between the near and far detectors are known to better than 0.2%. With the unblinding of the final two detectors’ baselines and target masses, a complete description and comparison of the eight antineutrino detectors can now be presented. This paper describes the Daya Bay detector systems, consisting of eight antineutrino detectors in three instrumented water pools in three underground halls, and their operation through the first year of eight detector data-taking.