The aim of the present study was to find out whether early cardiac changes in patients receiving chemotherapy can be detected by the conventional and deformation parameters of 2D and 3D ...echocardiography. Twenty-five healthy subjects with normal regional left ventricular function (group 1) and 25 patients receiving chemotherapy (group 2) underwent 2D and 3D transthoracic echocardiography (Toshiba Artida Medical System). All patients (group 2) were examined before and during cardiotoxic chemotherapy at a 3-month follow-up. Left ventricular volumes, ejection fraction, muscle mass, global longitudinal, global radial, global circumferential strain, and rotation were analyzed with 2D and 3D echocardiography, while twist and time-to-peak-intervals were analyzed with 3D echocardiography. For left ventricular volumes and muscle mass, no significant differences were seen between the two study groups (P<0.05). According to our results, myocardial dysfunction induced by cardiotoxic chemotherapy can be detected by 2D global radial strain. Detecting myocardial dysfunction by global longitudinal and circumferential strain requires more than 3 months follow-up. Changes in rotation, twist or time-to-peak intervals could not be verified at the 3-month follow-up in the present study. 2D global radial strain seems to be the most sensitive and robust parameter to detect early myocardial damage during chemotherapy. 3D echocardiography is not yet an established method to detect myocardial damage in clinical practice due to lower spatial and temporal resolution.
Valvular regurgitation represents an important cause of cardiovascular morbidity and mortality. Echocardiography has become the primary non-invasive imaging method for the evaluation of valvular ...regurgitation. The echocardiographic assessment of valvular regurgitation should integrate the quantification of the regurgitation, assessment of the valve anatomy and function, as well as the consequences of valvular disease on cardiac chambers. In clinical practice, the management of patients with valvular regurgitation thus largely integrates the results of echocardiography. It is crucial to provide standards that aim at establishing a baseline list of measurements to be performed when assessing regurgitation.
Purpose The study compares the feasibility of the quantitative volumetric and semi-quantitative approach for quantification of chronic aortic regurgitation (AR) using different imaging modalities. ...Methods Left ventricular (LV) volumes, regurgitant volumes (RVol) and regurgitant fractions (RF) were assessed retrospectively by 2D, 3D echocardiography and cMRI in 55 chronic AR patients. Semi-quantitative parameters were assessed by 2D echocardiography. Results 22 (40%) patients had mild, 25 (46%) moderate and 8 (14%) severe AR. The quantitative volumetric approach was feasible using 2D, 3D echocardiography and cMRI, whereas the feasibility of semi-quantitative parameters varied considerably. LV volume (LVEDV, LVESV, SVtot) analyses showed good correlations between the different imaging modalities, although significantly increased LV volumes were assessed by cMRI. RVol was significantly different between 2D/3D echocardiography and 2D echocardiography/cMRI but was not significantly different between 3D echocardiography/cMRI. RF was not statistically different between 2D echocardiography/cMRI and 3D echocardiography/cMRI showing poor correlations (r < 0.5) between the different imaging modalities. For AR grading by RF, moderate agreement was observed between 2D/3D echocardiography and 2D echocardiography/cMRI and good agreement was observed between 3D echocardiography/cMRI. Conclusion Semi-quantitative parameters are difficult to determine by 2D echocardiography in clinical routine. The quantitative volumetric RF assessment seems to be feasible and can be discussed as an alternative approach in chronic AR. However, RVol and RF did not correlate well between the different imaging modalities. The best agreement for grading of AR severity by RF was observed between 3D echocardiography and cMRI. LV volumes can be verified by different approaches and different imaging modalities.
In this prospective study, we aimed to assess the haemodynamic changes before and after haemodialysis (HD) in cardiac healthy subjects on chronic HD by imaging methods and endocrine markers of fluid ...balance.
Mid-regional pro-atrial natriuretic peptide (MR-proANP), N-terminal prohormone of brain natriuretic peptide (NT-proBNP), vasopressin (AVP) and copeptin (CT-proAVP), metanephrines and normetanephrines, renin and aldosterone, standard transthoracic echocardiography and diameter of vena cava inferior (VCID) were performed in 20 patients with end stage renal disease (CKD5D) before and after HD and were stratified in residual excretion (RE, less or more 0.5 l) and ultrafiltration rate (UF, less or more 2 l).
Copeptin was significantly higher in patients before HD. Copeptin was inversely correlated with haemodialysis treatment adequacy (KT/v), RE and UF, but was not significantly influenced by age, gender and body mass index (BMI). MR-proANP was significantly reduced by haemodialysis by 27% and was inversely correlated with KT/v, but there was a significant influence by UF, RE, age, gender and BMI. NT-proBNP was significantly higher in patients before HD and was not influenced by RE and UF. Renin, aldosterone, metanephrines and normetanephrines did not demonstrate significant differences. Echocardiographic parameters and VCID were significantly correlated with RE, UF and copeptin.
Modern biomarkers will provide cardiovascular risk assessment, but elimination (UF), RE and other factors may influence the serum concentrations, e.g. in patients with renal impairment. The interpretation will be limited by altered reference ranges, and will be restricted to individual courses combined with clinical and echocardiographic data.
Abstract
Aims
The present Euro-Filling report aimed at comparing the diagnostic accuracy of the 2009 and 2016 echocardiographic grading algorithms for predicting invasively measured left ventricular ...filling pressure (LVFP).
Method and results
A total of 159 patients who underwent simultaneous evaluation of echo estimates of LVFP and invasive measurements of LV end-diastolic pressure (LVEDP) were enrolled at nine EACVI centres. Thirty-nine (25%) patients had a reduced LV ejection fraction (<50%), 77 (64%) were in NYHA ≥ II, and 85 (53%) had coronary artery disease. Sixty-four (40%) patients had elevated LVEDP (≥15 mmHg). Taken individually, all echocardiographic Doppler estimates of LVFP (E/A, E/e′, left atrial volume, tricuspid regurgitation jet velocity) were marginally correlated with LVEDP. By using the 2016 recommendations, 65% of patients with normal non-invasive estimate of LVFP had normal LVEDP, while 79% of those with elevated non-invasive LVFP had elevated invasive LVEDP. By using 2009 recommendations, 68% of the patients with normal non-invasive LVFP had normal LVEDP, while 55% of those with elevated non-invasive LVFP had elevated LVEDP. The 2016 recommendations (sensitivity 75%, specificity 74%, positive predictive value 39%, negative predictive value 93%, AUC 0.78) identified slightly better patients with elevated invasive LVEDP (≥ 15 mmHg) as compared with the 2009 recommendations (sensitivity 43%, specificity 75%, positive predictive value 49%, negative predictive value 71%, AUC 0.68).
Conclusion
The present Euro-Filling study demonstrates that the new 2016 recommendations for assessing LVFP non-invasively are fairly reliable and clinically useful, as well as superior to the 2009 recommendations in estimating invasive LVEDP.
Functional diagnostics by rational echocardiography are the base of a verifiable and reliable analysis of ventricular and valvular function. The most important functional parameters in ...echocardiography are cardiac volumes - especially total and effective left ventricular stroke volume -, global longitudinal strain, effective orifica areas in valvular stenoses and effective regurgitant volumes, regurgitant fraction and regurgitant orifice areas in valvular regurgitations. Standardized documentation and correct measurements are the prerequisites for accurate echocardiographic estimations. In addition, optimization of image quality supports the correctness of measurements to ensure plausibility of hemodynamics in each individual patient. However, measurements of cardiac volumes by planimetry are error-prone. In addition, calculation of the effective orifice areas using the continuity equation needs methodological accuracy and standardization. Finally, assessment of regurgitant volumes, regurgitant fraction, and regurgitant orifice is often inconsistent with stable hemodynamic conditions - especially by functional assessment the 2D-PISA method. Thus, functional diagnostics by echocardiography in valvular heart diseases should focus on a plausible hemodynamic assessment.
Abstract
Aims
This European Association Cardiovascular Imaging (EACVI) Expert Consensus document aims at defining the main quantitative information on cardiac structure and function that needs to be ...included in standard echocardiographic report following recent ASE/EACVI chamber quantification, diastolic function, and heart valve disease recommendations. The document focuses on general reporting and specific pathological conditions such as heart failure, coronary artery and valvular heart disease, cardiomyopathies, and systemic diseases.
Methods and results
Demographic data (age, body surface area, blood pressure, and heart rhythm and rate), type (vendor and model) of ultrasound system used and image quality need to be reported. In addition, measurements should be normalized for body size. Reference normal values, derived by ASE/EACVI recommendations, shall always be reported to differentiate normal from pathological conditions. This Expert Consensus document suggests avoiding the surveillance of specific variable using different ultrasound techniques (e.g. in echo labs with high expertise in left ventricular ejection fraction by 3D and not by 2D echocardiography). The report should be also tailored in relation with different cardiac pathologies, quality of images, and needs of the caregivers.
Conclusion
The conclusion should be concise reflecting the status of left ventricular structure and function, the presence of left atrial and/or aortic dilation, right ventricular dysfunction, and pulmonary hypertension, leading to an objective communication with the patient health caregiver. Variation over time should be considered carefully, taking always into account the consistency of the parameters used for comparison.
Connexin40-deficient (Cx40(-/-)/Cx43(+/+)) and connexin43-heterozygous knockout mice (Cx40(+/+)/Cx43(+/-)) are viable but show cardiac conduction abnormalities. The ECGs of adult double heterozygous ...animals (Cx40(+/-)/Cx43(+/-)) suggest additive effects of Cx40 and Cx43 haploinsufficiency on ventricular, but not on atrial, conduction. We also observed additive effects of both connexins on cardiac morphogenesis. Approximately half of the Cx40(-/-)/Cx43(+/+) embryos died during the septation period, and an additional 16% died after birth. The majority of the latter mice had cardiac hypertrophy in conjunction with common atrioventricular junction or a ventricular septal defect. All Cx40(-/-)/Cx43(+/-) progeny exhibited cardiac malformations and died neonatally. The most frequent defect was common atrioventricular junction with abnormal atrioventricular connection, which was more severe than that seen in Cx40(-/-)/Cx43(+/+) mice. Furthermore, muscular ventricular septal defects, premature closure of the ductus arteriosus, and subcutaneous edema were noticed in these embryos. Cx40(+/-)/Cx43(-/-) embryos showed the same phenotype (ie, obstructed right ventricular outflow tract) as reported for Cx40(+/+)/Cx43(-/-) mice. These findings demonstrate that Cx43 haploinsufficiency aggravates the abnormalities observed in the Cx40(-/-) phenotype, whereas Cx40 haploinsufficiency does not worsen the Cx43(-/-) phenotype. We conclude that the gap-junctional proteins Cx40 and Cx43 contribute to morphogenesis of the heart in an isotype-specific manner.
The frequency of concomitant cusp pathology in aortic root aneurysm with or without aortic regurgitation is not well known, and the sensitivity and specificity of two-dimensional trans-oesophageal ...echocardiography (2D TEE) in its detection has not yet been specified.
We analysed the type and frequency of concomitant cusp alterations in root aneurysm referred for surgery. Sensitivity and specificity of 2D TEE in detecting these alterations were determined.
In 582 patients (age 56.8±15.4 years, 453 male) with trileaflet aortic valves undergoing root replacement for regurgitation (n=347) or aneurysm (n=235), details of valve morphology were analysed. In a subcohort (n=281), intraoperative TEEs were analysed retrospectively and correlated with the intraoperative findings.
Any cusp pathology was present in 90.9% (prolapse: n=473; retraction: n=30; calcification: n=14; fenestration: n=12), morphologically normal cusps were seen in only 52 patients (8.93%). Valve-sparing surgery was performed in 525 (90.2%) instances, composite replacement in 57 (9.8%). Preoperative TEE correctly identified any postroot repair prolapse in 70.6% and any retraction in 85%. The sensitivity of TEE in detecting any prolapse was 68.6% (specificity of 79.5%). The sensitivity was highest for the right cusp and intermediate for the non-coronary.
Cusp prolapse is frequent in root aneurysm and trileaflet aortic valves. Prolapse is underdiagnosed by 2D TEE in many cases because pre-existent stretching of cusp tissue is masked by the geometric effects of root dilatation.
Aims The present Euro-Filling report aimed at comparing the diagnostic accuracy of the 2009 and 2016 echocardiographic grading algorithms for predicting invasively measured left ventricular filling ...pressure (LVFP). Method and results A total of 159 patients who underwent simultaneous evaluation of echo estimates of LVFP and invasive measurements of LV end-diastolic pressure (LVEDP) were enrolled at nine EACVI centres. Thirty-nine (25%) patients had a reduced LV ejection fraction (< 50%), 77 (64%) were in NYHA >= II, and 85 (53%) had coronary artery disease. Sixty-four (40%) patients had elevated LVEDP (>= 15 mmHg). Taken individually, all echocardiographic Doppler estimates of LVFP (E/A, E/e', left atrial volume, tricuspid regurgitation jet velocity) were marginally correlated with LVEDP. By using the 2016 recommendations, 65% of patients with normal non-invasive estimate of LVFP had normal LVEDP, while 79% of those with elevated non-invasive LVFP had elevated invasive LVEDP. By using 2009 recommendations, 68% of the patients with normal non-invasive LVFP had normal LVEDP, while 55% of those with elevated non-invasive LVFP had elevated LVEDP. The 2016 recommendations (sensitivity 75%, specificity 74%, positive predictive value 39%, negative predictive value 93%, AUC 0.78) identified slightly better patients with elevated invasive LVEDP (>= 15 mmHg) as compared with the 2009 recommendations (sensitivity 43%, specificity 75%, positive predictive value 49%, negative predictive value 71%, AUC 0.68). Conclusion The present Euro-Filling study demonstrates that the new 2016 recommendations for assessing LVFP noninvasively are fairly reliable and clinically useful, as well as superior to the 2009 recommendations in estimating invasive LVEDP.